Skip to content

The Tektronix Passive High Voltage Probe series comprises the P5100, P5102, P5120, and P6015A — passive probes for measuring high voltages with oscilloscopes and plug-ins. The P5100 is a low-input-capacitance high voltage probe rated to 2.5 kV, designed for higher-frequency applications. The P6015A is the heavy-duty member of the family, intended for measurements over 2.5 kV. The P5102 and P5120 provide isolated-channel measurement when paired with their companion oscilloscope series.
This series targets power electronics measurement work. The listed applications are power supply design, motor drive design, electronic ballast, power semiconductors, switch mode control, UPS systems, and power converters.
ValueTronics stocks this equipment in its own 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified by our technicians in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.
The Passive High Voltage Probes family groups four Tektronix probes — the P5100, P5102, P5120, and P6015A — into a single passive high-voltage measurement series for power electronics work. The lineup ranges from the low-input-capacitance P5100, designed for higher-frequency applications up to 2.5 kV, to the P6015A, described as the industry standard for heavy-duty measurements over 2.5 kV.
Two members, the P5102 and P5120, are isolated-channel probes intended to pair with specific Tektronix handheld and portable oscilloscope series, isolating the measurement from earth ground and isolating common voltage between channels.
Each pre-owned model in this series is offered on its own dedicated product page with condition-matched pricing. Select the specific model that matches your measurement requirements; the comparison table below summarizes how the probes differ.
The probes differ primarily in bandwidth, attenuation, maximum rated input voltage, and compensation range. Bandwidth spans 75 MHz on the P6015A to 250 MHz on the P5100; attenuation factors are 10X on the P5102, 20X on the P5120, 100X on the P5100, and 1,000X on the P6015A. Maximum inputs range from 1,000 VRMS CAT II on the isolated-channel P5102 and P5120 to 2.5 kV (DC + peak AC) on the P5100 and 20 kV DC / 40 kV peak on the P6015A.
The P5102 and P5120 add channel-to-channel and earth-ground isolation for use with the THS700 and TPS2000 Series respectively, while the P6015A offers length and readout configuration options. Refer to the comparison table for each model's bandwidth, rise time, loading, maximum input and float voltage, and compensation range.
| Model | Attenuation | Bandwidth | Max Input Voltage |
|---|---|---|---|
| P5102 | 10X | 100 MHz | 1,000 VRMS CAT II |
| P5100 | 100X | 250 MHz | 2.5 kV (DC + Pk AC); 1,000 V CAT III |
| P5120 | 20X | 200 MHz | 1,000 VRMS CAT II |
| P6015A | 1000X | 75 MHz | 20 kV |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Characteristics | |
| Nominal Attenuation | 10X |
| Bandwidth | 100 MHz |
| Rise Time (typical) | 3.5 ns |
| Loading | 5 MΩ / 11.2 pF |
| Max. Input V (DC or RMS) | 1,000 VRMS CAT II |
| Max. Float V | 600 VRMS CAT II |
| Compensation Range | 24 to 28 pF |
| Readout | No |
| Cable Length | 2 m |
| Safety Certifications | |
| Standards | UL3111-1, EN61010-1, IEC61010-2-031, CSA1010.1, CSA1010.2.031 |
Important: Note: Using the readout version with other than Tektronix digital scopes may result in an erroneous readout display.
Important: Recommended accessories for the P5100 are ordered separately: Probe Tip to BNC Adapter (order 013-0291-00) and 0.080 in. Diameter Spring Tip (order 206-0060-00).
Important: Service options C3, C5, D1, D3, D5, R3, and R5 are listed for the P6015 only.
Usage tip: the P5102 is designed for the THS700 Series and the P5120 for the TPS2000 Series oscilloscopes named in the datasheet's compatibility text.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Pre-Owned
Manufacturer
Tektronix
Volt_prob_freq
100 MHz
Volt_prob_volts
1,000 VRMS
Request A Quote