Key Features At A Glance

  • Bandwidth options from 600 MHz (DSO8064A/MSO8064A) to 1 GHz (DSO8104A/MSO8104A) across the family
  • Sample rates up to 4 GSa/s on 2 channels or 2 GSa/s on each of 4 channels
  • Available as 4-channel DSO or as MSO with 4 analog plus 16 digital timing channels
  • Standard 4 Mpts memory per channel (8 Mpts on 2 channels), upgradable up to 128 Mpts on 2 channels
  • 8.4 inch XGA color TFT-LCD touch screen with 256-level intensity-graded display
  • Built-in GPIB, 10/100/1000 BaseT LAN, USB 2.0, and LXI Class C compliance
  • Compact 5U high form factor designed for rackmount and stacked-instrument environments
  • Windows XP Pro platform enables installation of third-party applications such as MATLAB, Excel, and LabVIEW
Share on
View full details

The Agilent Infiniium 8000 Series is a family of four-channel digital storage and mixed-signal oscilloscopes engineered for mixed-signal analysis and debug. The series consists of four models: the DSO8064A and MSO8064A at 600 MHz bandwidth, and the DSO8104A and MSO8104A at 1 GHz bandwidth. DSO variants provide four analog channels, while MSO variants add 16 digital timing channels for time-correlated analog and digital measurement. All models share a common 5U high chassis with an 8.4 inch XGA touch screen display, built-in GPIB, and the Infiniium user interface.

The 8000 Series is positioned for engineers working across a range of debug and test challenges, including hardware design verification, embedded systems development, FPGA debug, serial bus analysis, and rackmount production test environments. The MSO models add 16 digital channels suited to evaluating control signal relationships and data buses up to 16 bits wide alongside time-correlated analog measurements. When paired with the optional FPGA dynamic probe for Altera or Xilinx, the digital channels can also be used for rapid internal FPGA measurements. The low-profile 5U chassis makes the series suitable for rackmount applications where stacked instrumentation or rack integration is required.

ValueTronics International stocks, tests, and ships the Infiniium 8000 Series from its 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Each {{CONDITION}} unit is inventoried in our facility, allowing our team to verify configuration, accessories, and operating condition before the instrument leaves for the customer. This in-house handling distinguishes our model from pass-through brokers and drop-shippers who never physically touch the equipment they sell.

Brand Heritage

The Infiniium oscilloscope line originated within Hewlett-Packard's test and measurement business, which was spun off as Agilent Technologies in 1999. Agilent's electronic measurement business subsequently became Keysight Technologies in 2014. Instruments branded "Agilent Infiniium" are part of this lineage, and the 8000 Series carries the Agilent branding from its original release period.

Compare Other Models in This Series

The Infiniium 8000 Series consists of four models built on a common 5U chassis and shared Infiniium platform. The two performance tiers are defined by bandwidth: 600 MHz on the 8064A models and 1 GHz on the 8104A models. Within each bandwidth tier, the series is offered as either a four-channel DSO or as an MSO that adds 16 digital timing channels for mixed-signal work.

All four models share the same maximum sample rate (4 GSa/s on 2 channels, 2 GSa/s on each of 4 channels), the same standard memory depth (4 Mpts per channel, 8 Mpts on 2 channels), the same XGA touch-screen display, and the same connectivity package including built-in GPIB, LAN, and USB 2.0. The differences between models are bandwidth tier and the presence or absence of the 16 digital channels.

Each model in the Infiniium 8000 Series listed below has its own product page with pre-owned-matched pricing. Use the comparison table to confirm bandwidth and channel configuration, then proceed to the specific model page for current availability.

The two primary differentiators across the family are bandwidth and digital channel count. Bandwidth selection (600 MHz vs. 1 GHz) is driven by the highest-frequency signal the user needs to capture accurately; the 1 GHz models also have a faster calculated rise time (350 ps vs. 583 ps) and lower jitter measurement floor. The DSO vs. MSO decision is driven by whether the user needs to view digital buses or control signals time-correlated to analog waveforms; the MSO models add 16 digital channels with selectable thresholds (TTL, CMOS, ECL, PECL, or user-defined) and glitch detection down to 2.5 ns.

Memory depth is identical at the standard level across all four models. Factory-installed and user-installable memory upgrade options (080, 160, 320, and 640) extend the memory uniformly across the family up to a maximum of 128 Mpts on 2 channels or 64 Mpts on 4 channels. See the comparison table below for the per-model summary.

Model Bandwidth Analog Channels Digital Channels
DSO8064A 600 MHz 4
MSO8064A 600 MHz 4 16
DSO8104A 1 GHz 4
MSO8104A 1 GHz 4 16

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Optical USB mouse
  • Condensed keyboard
  • User's Quick Start Guide (English; other languages available)
  • Accessory pouch
  • Front panel cover
  • Power cord
  • 10073C 10:1 passive probe (qty 4)

Product Core & Specifications

Vertical: Scope Channels (DSO8064A, MSO8064A, DSO8104A, MSO8104A)
Input channels DSO8064A/DSO8104A: 4 analog; MSO8064A/MSO8104A: 4 analog + 16 digital
Analog bandwidth at 50 Ω (−3 dB) DSO8064A/MSO8064A: 600 MHz; DSO8104A/MSO8104A: 1 GHz
Calculated rise time at 50 Ω DSO8064A/MSO8064A: 583 ps; DSO8104A/MSO8104A: 350 ps
Input impedance 1 MΩ ± 1% (13 pF typical), 50 Ω ± 1.5%
Sensitivity 1 mV/div to 5 V/div (1 MΩ); 1 mV/div to 1 V/div (50 Ω)
Input coupling 1 MΩ: AC, DC; 50 Ω: DC
Hardware bandwidth limit 20 MHz
Vertical resolution 8 bits, ≥12 bits with averaging
Channel-to-channel isolation DC to 50 MHz: 50 dB; >50 MHz to 500 MHz: 40 dB; >500 MHz to 1 GHz: 30 dB
DC gain accuracy ± 1.25% of full scale at full resolution channel scale
Maximum input voltage (1 MΩ) 150 V RMS or DC, CAT I; ± 250 V (DC + AC) in AC coupling
Maximum input voltage (50 Ω) 5 Vrms, CAT I
Dynamic range ± 8 div from center screen (1 MΩ); ± 12 div from center screen (50 Ω)
Vertical: Digital Channels (MSO8064A, MSO8104A)
Number of channels 16 digital — labeled D15 to D0
Threshold groupings Pod 1: D7 to D0; Pod 2: D15 to D8
Threshold selections TTL, 5.0V CMOS, 3.3V CMOS, 2.5V CMOS, ECL, PECL, user defined
User-defined threshold range ± 8.00 V in 10 mV increments
Maximum input voltage ± 40 V peak CAT I
Threshold accuracy ± (100 mV + 3% of threshold setting)
Input dynamic range ± 10 V about threshold
Minimum input voltage swing 500 mV peak-to-peak
Input impedance 100 kΩ ± 2% (~ 8 pF) at probe tip
Channel-to-channel skew 2 ns typical, 3 ns maximum
Glitch detect ≥ 2.5 ns
Horizontal
Main time base range DSO8064A/MSO8064A: 500 ps/div to 20 s/div; DSO8104A/MSO8104A: 200 ps/div to 20 s/div
Horizontal position range 0 to ± 200 s
Delayed sweep range 1 ps/div to current main time base setting
Resolution 4 ps
Time scale accuracy ± (15 + 2 · (years since manufacture)) ppm
Channel-to-channel deskew range −100 µs to 100 µs
Modes Main, delayed, roll
Reference positions Left, center, right
Acquisition: Scope Channels
Real time sample rate (max), 2 channels 4 GSa/s
Real time sample rate (max), each channel 2 GSa/s
Equivalent time sample rate (max) 250 GSa/s
Memory depth, Standard (2-ch/4-ch) 8 Mpts / 4 Mpts
Memory depth, Option 080 16 Mpts / 8 Mpts
Memory depth, Option 160 32 Mpts / 16 Mpts
Memory depth, Option 320 64 Mpts / 32 Mpts
Memory depth, Option 640 128 Mpts / 64 Mpts
Averaging Selectable from 2 to 65,534
Segmented memory Up to 32,768 segments depending on memory option; min inter-segment time 20 µs
Acquisition: Digital Channels (MSO Models)
Maximum input frequency 250 MHz
Maximum real time sample rate 1 GSa/s
Memory depth per channel 32 M
Minimum width glitch detection 2.5 ns
Trigger
Sensitivity (Internal) DC to 600 MHz: 0.6 div; 600 MHz to 1 GHz: 1.5 div (50 Ω)
Sensitivity (Auxiliary) DC to 600 MHz: 300 mVp-p
Level range (Internal) ± 8 div from center screen (1 MΩ and 50 Ω)
Level range (Auxiliary) ± 5 V
Sweep modes Auto, triggered, single
Trigger coupling DC, AC, low frequency reject (50 kHz high pass), high frequency reject (50 kHz low pass)
Trigger holdoff range 50 ns to 10 s
Trigger jitter 8 ps ± 0.05 ppm x |delay setting| rms
Trigger modes Edge, Glitch, Line, Pattern, State, Delay by time, Delay by events, TV
Violation triggers Pulse width, Setup/hold, Transition
Display
Display 8.4 inch color XGA TFT-LCD with touch screen
Intensity grayscale 256-level intensity-graded display
Resolution 1024 x 768 pixels
Important: Maximum input voltage at the 1 MΩ inputs is 150 V RMS or DC (CAT I), and 5 Vrms (CAT I) at the 50 Ω inputs. Maximum input voltage on the MSO digital channels is ±40 V peak (CAT I).Important: For the 1 GHz models (DSO8104A and MSO8104A), an active probe with bandwidth of at least 1 GHz (such as the 1156A or 1130A) is required to achieve the full system bandwidth of the oscilloscope.Important: The 1130A 1.5 GHz InfiniiMax probe amplifier does not include probe heads; a connectivity kit or individual probe head (E2675A, E2668A, or E2669A) must be ordered separately for a complete probing solution.Important: The N2780A series current probes require the N2779A 3-channel power supply, ordered separately.Important: The N5430A Infiniium user-defined function requires MATLAB software, purchased separately.Recommended pairing: the 1156A 1.5 GHz active probe or the 1130A 1.5 GHz InfiniiMax probe amplifier, both listed in the datasheet as the recommended probes to achieve the full system bandwidth of the 1 GHz Infiniium 8000 Series models.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Channels

4

Frequency

600 MHz

Record length

8 MPts

Sampling rate

4 GS/s