Keysight DAQM908A Single-Ended Multiplexer Module

Keysight DAQM908A Single-Ended Multiplexer Module

Regular price $895
Sale price $895 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Keysight DAQM908A Single-Ended Multiplexer Module

Key Features At A Glance

  • Built-in 6½-digit digital multimeter and signal conditioning — no external measurement boxes required
  • Measures 14 input signal types, including new capacitance, diode-test, and direct/bridge strain measurements
  • Added ranges: 1000 MΩ resistance, 1 µA DC current, and 100 µA / 1 mA AC current
  • Multiplexer scan rate up to 450 channels/sec with the DAQM900A solid-state multiplexer module
  • Color LCD displays readings as number, bar meter, trend chart, or histogram
  • DAQM909A digitizer module adds 24-bit, 800 kSa/s four-channel simultaneous sampling
  • USB and LAN standard; GPIB available on the DAQ973A for automated test systems
  • BenchVue DAQ software automates tests without programming; 20 computed channels for math operations
View full details

The Keysight DAQ970A/DAQ973A is a data acquisition system that combines a built-in 6½-digit digital multimeter and signal conditioning in a three-slot mainframe, eliminating the need for external measurement boxes. It is the next-generation design that builds on the proven 34970A/34972A architecture, adding a color LCD, internal module auto-calibration, and improved temperature accuracy and measurement speeds while maintaining compatibility with the earlier platform.

The system measures and converts 14 different input signal types: temperature via thermocouples, RTDs, and thermistors; DC and AC volts; 2- and 4-wire resistance; frequency and period; DC and AC current; and new capacitance, diode-test, direct-strain, and bridge-strain measurements. The DAQM909A four-channel simultaneous sampling digitizer module captures fast transient signals from electromechanical devices, while BenchVue DAQ software configures and controls tests, displays results, and exports data for further analysis.

Brand Heritage

Keysight Technologies traces its test-and-measurement lineage to Hewlett-Packard. HP's instrument business was spun off as Agilent Technologies in 1999, and Agilent's electronic measurement division became Keysight Technologies in 2014.

Compare Other Models in This Series

The DAQ970A/DAQ973A is presented as a single next-generation data acquisition platform offered in two mainframe variants. Both share the same three-slot chassis, the built-in 6½-digit digital multimeter with auto-calibration, the 14 measurement types, the color LCD interface, and compatibility with the family's plug-in switch, multifunction, and digitizer modules.

The two variants are distinguished primarily by their remote-control interfaces. The comparison table below summarizes how the DAQ970A and DAQ973A line up on connectivity and shared measurement capability.

Each new model below is its own dedicated product page with condition-matched pricing. Choose the variant whose interface set fits your bench or automated test system, then select the configuration that matches your application.

The principal difference between the two variants is connectivity. The DAQ970A provides USB (front and back panel) and LAN interfaces, while the DAQ973A adds GPIB alongside its USB and LAN connections, suiting installations that standardize on an IEEE-488 bus.

Apart from the interface set, the two variants share the same measurement engine, scan performance, module compatibility, and display. The comparison table details the connectivity and capability of each model so you can match the variant to your integration environment.

Model Type Channels / Slots Scan Rate
DAQM908A Single-ended multiplexer
DAQ970A Data Acquisition Mainframe 3 slots Up to 450 ch/sec
DAQ973A Data Acquisition Mainframe 3 slots Up to 450 ch/sec
DAQM900A Solid-state switch multiplexer 20 channels Up to 450 ch/sec

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Replaces: per the manufacturer, this model replaces 34970A, 34972A.

Product Core & Specifications

Specification Value
System Architecture
Plug-in module slots 3
Built-in DMM 6½-digit resolution, with auto calibration
Multiplexer scan rate Up to 450 channels per second
Types of measurements Measures and converts 14 different input signals (DC/AC volts; 2- and 4-wire resistance; frequency and period; DC/AC current; temperature with thermocouples, RTDs and thermistors; capacitance; diode test; direct strain and bridge strain)
Added ranges vs. 34970A/34972A 1000 MΩ range for resistance; 1 µA range for DC current; 100 µA and 1 mA ranges for AC current; square wave input for frequency
Display Color LCD/GUI
Computed channels 20 channels (channels 401 through 420) performing math operations (addition, subtraction, multiplication, division, reciprocal, power, square root)
Single-channel digitizing (internal DMM) Up to 50 kSa/s
Digitizing with DAQM909A module Up to 800 kSa/s
DC, Resistance & AC Accuracy (1 Year, ± (% of reading + % of range))
DCV (1 V) 0.0035 + 0.0006
DCV (300 V) 0.0040 + 0.0020
Resistance (1 kΩ) 0.0040 + 0.0007
Resistance (1 MΩ) 0.0070 + 0.0005
Resistance (100 MΩ) 0.350 + 0.001
Resistance (1000 MΩ) 3.500 + 0.001
DCA (1 A) 0.080 + 0.010
ACV (up to 100 V range at 10 Hz to 20 kHz) 0.05 + 0.02
ACV (up to 300 V range at 10 Hz to 20 kHz) 0.05 + 0.06
ACA (up to 1 mA range at 5 kHz to 10 kHz) 0.10 + 0.04
ACA (up to 1 A range at 5 kHz to 10 kHz) 0.10 + 0.04
Frequency (1 kHz to 300 kHz) 0.007
Temperature Accuracy (°C)
Thermocouple (J type) 1.0 °C
Thermocouple (K type) 0.9 °C
Thermocouple (R type) 0.5 °C
RTD (R0 from 49 Ω to 2.1 kΩ) 0.05 °C
Thermistor (2.2 kΩ, 5 kΩ, 10 kΩ) 0.1 °C
Performance
Max measurement speed (single-channel ASCII readings — DCV, ohms) 50,000 readings per second
Internal memory 1,000,000 scan readings
DAC output (voltage output) 0.027 output + 4.4 mV
Important: Removing a module while the DAQ970A/DAQ973A is powered on causes an immediate power-on reset of the mainframe.
Important: All the modules the DAQ970A/DAQ973A offers cannot be used on the 34970A/34972A mainframe, and vice versa; the module families are not interchangeable.
Important: The DAQM908A single-ended mux card does not support thermocouple temperature measurements.
Recommended pairing: the DAQM900A solid-state multiplexer module enables the up-to-450-channels-per-second scan rate, and the DAQM909A digitizer module adds 24-bit, 800 kSa/s capture of fast transient signals.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

Factory New

Manufacturer

Keysight Technologies

Plugin_type

40-Channel Single-Ended Multiplexer

Keysight DAQM905A Dual 4-Channel 50 Ohm RF Multiplexer Module for DAQ970A/DAQ973A

DAQM905A

Keysight DAQM902A 16-Channel Reed Multiplexer Module for DAQ970A/DAQ973A

DAQM902A

Keysight DAQM903A 20-Channel Actuator/General Purpose Switch Module for DAQ970A/DAQ973A

DAQM903A

Keysight DAQM904A 4x8 Two-Wire Matrix Switch Module for DAQ970A/DAQ973A

DAQM904A

Keysight DAQM901A 20-Channel Armature Multiplexer Module for DAQ970A/DAQ973A

DAQM901A

34307A Keysight Accessory New

34307A

Keysight 34194A Dual-Lock Link Kit for 53200 Series Frequency Counter/Timers

34194A

34308A Keysight Accessory New

34308A

11062A Keysight Accessory New

11062A