Key Features At A Glance

  • Three models spanning RF and universal counter/timer functions with 350 MHz baseband input bandwidth
  • Optional 6 GHz or 15 GHz microwave input channels for extended frequency coverage
  • Up to 12 digits/second frequency resolution on a one-second gate
  • 20 ps single-shot time interval resolution (53230A) — input-signal-noise and slew-rate dependent
  • LAN (LXI-C), USB 2.0, and GPIB interfaces standard for automated test system integration
  • 1 M reading volatile memory plus 75 MB non-volatile internal storage with front-panel USB flash support
  • Built-in datalog trend plot, cumulative histogram, math analysis, and statistics for on-instrument insight
  • 4.3-inch color TFT display with LXI Class C compliant web user interface
View full details

The Keysight 53200A Series comprises three RF and universal frequency counter/timers — the 53210A, 53220A, and 53230A — designed to deliver frequency and time interval measurements with the resolution, speed, and analysis capabilities required for both R&D and manufacturing environments. The series builds on Keysight's heritage in time and frequency measurement, expanding traditional counter functionality with built-in graphical analysis, deep measurement memory, and modern connectivity.

Per the datasheet, the 53200A Series supports frequency, frequency ratio, period, voltage level, and RF signal strength measurements across all three models. The 53220A and 53230A add time interval, pulse width, rise/fall time, duty cycle, phase, and totalize measurements. The 53230A further enables continuous gap-free measurements, timestamped data for modulation domain analysis, and — when configured with the 6 GHz or 15 GHz microwave option — pulse and burst measurements including carrier frequency, pulse repetition frequency (PRF), pulse repetition interval (PRI), and burst positive/negative width.

ValueTronics International stocks, tests, and supports the Keysight 53200A Series from a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every instrument is inspected and performance-verified by our in-house technicians before shipment, with condition documentation accompanying the unit. Our depth in time and frequency instrumentation — across new authorized distribution, verified used inventory, and trade-in offset programs — lets us match a 53210A, 53220A, or 53230A to your application from multiple sourcing paths rather than a single channel.

Brand Heritage

Keysight Technologies was established in 2014 when Agilent Technologies separated its electronic measurement business. Agilent itself originated in 1999 as a spin-off from Hewlett-Packard's test and measurement, semiconductor products, chemical analysis, and medical businesses. The 53200A Series continues a long heritage of HP, Agilent, and now Keysight frequency counters that have served R&D and manufacturing benches for decades.

Compare Other Models in This Series

The 53200A Series is structured as a three-tier family. The 53210A is positioned as the RF frequency counter, providing frequency, frequency ratio, period, and voltage-level measurements on the standard channel and adding RF signal strength when the microwave channel option is installed. The 53220A and 53230A are universal counter/timers, extending the measurement set to include time interval, pulse width, rise/fall time, duty cycle, phase, and totalize functions across two standard 350 MHz channels.

Within the universal counter pair, the 53230A is the higher-resolution and higher-capability model. It adds 20 ps single-shot time resolution (versus 100 ps on the 53220A), continuous gap-free measurements, timestamped acquisition for modulation domain analysis, and — when paired with the optional microwave channel — pulse and burst measurement support including carrier frequency, PRF, PRI, and burst positive/negative width.

Each new 53200A Series model below is its own dedicated product page with condition-matched pricing and configuration options. Use the links to navigate to the specific model that matches your application — base model, OCXO timebase, microwave channel option, or battery configuration — and confirm option codes against the unit you receive.

The three models differ along three primary axes that the datasheet describes explicitly: measurement function set, resolution, and acquisition mode. The 53210A is limited to frequency-domain measurements (frequency, ratio, period, voltage level, and optional RF signal strength). The 53220A and 53230A add the full time-interval measurement set — single-shot time interval, pulse width, rise/fall time, duty cycle, and phase. Single-shot time resolution steps from N/A on the 53210A to 100 ps on the 53220A to 20 ps on the 53230A.

Acquisition capability differs at the top of the family. The 53230A is the only model offering continuous gap-free measurements and timestamped acquisition (up to 1 MSa/s, with acquisition lengths up to 1 million samples or 100,000 seconds), enabling modulation domain analysis workflows. The 53230A is also the only model supporting pulse and burst measurements with the optional microwave channel. The comparison table that follows summarizes the measurement-by-model matrix from the datasheet.

Model Frequency Range Resolution Single-Shot Time Resolution
53210A DC (1 mHz) to 350 MHz 10 digits/s
53220A DC (1 mHz) to 350 MHz 12 digits/s 100 ps
53230A DC (1 mHz) to 350 MHz 12 digits/s 20 ps

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • IEC Power Cord
  • USB cable
  • CD with User's guide, SCPI/programmers' reference, programming examples, drivers (IVI-COM, LabView), IO library instructions
  • 2 m USB 2.0 cable

Product Core & Specifications

Specification 53210A 53220A 53230A
Baseband frequency range (DC coupled) DC (1 mHz) to 350 MHz DC (1 mHz) to 350 MHz DC (1 mHz) to 350 MHz
Standard input channels Ch 1 Ch 1 & Ch 2 Ch 1 & Ch 2
Optional microwave input channel Ch 2 (6 or 15 GHz) Ch 3 (6 or 15 GHz) Ch 3 (6 or 15 GHz)
Resolution 10 digits/s 12 digits/s 12 digits/s
Maximum display resolution 12 digits 15 digits 15 digits
Single-shot time resolution N/A 100 ps 20 ps
Channel-to-channel time skew (typ) N/A 100 ps 50 ps
Measurement technique Reciprocal Reciprocal and resolution enhanced Reciprocal, resolution-enhanced or continuous (gap-free)
Gate time 1 ms to 1000 s in 10 µs steps 100 µs to 1000 s in 10 µs steps 1 µs to 1000 s in 1 µs steps
External trigger rate 300/s max 1 k/s max 10 k/s max
Standard input connector Front panel BNC(f); Option 201 adds parallel rear panel BNC(f) inputs
Input impedance (typ) Selectable 1 MΩ ± 1.5% or 50 Ω ± 1.5% || <25 pF
Input coupling Selectable DC or AC
Input range ±5 V (±50 V) full scale ranges
Sensitivity (typ) DC - 100 MHz: 20 mVpk; > 100 MHz: 40 mVpk
50 Ω damage level 1 W
1 MΩ damage level (DC - 5 kHz) 350 Vpk (AC + DC)
Option 106 microwave frequency range 100 MHz - 6 GHz
Option 115 microwave frequency range 300 MHz - 15 GHz
Microwave input connector Front panel precision Type-N(f); Option 203 moves to rear panel SMA(f)
Microwave input impedance (typ) 50 Ω ± 1.5% (SWR < 2.5)
Volatile reading memory 1 M readings (16 MBytes)
Non-volatile internal memory 75 Mbytes (up to 5 M readings)
Display 4.3" Color TFT WQVGA (480 x 272), LED backlight
Programming interface LXI-C 1.3, 10/100/1000 LAN, USB 2.0 (USB-TMC488), GPIB (IEEE-488.1, IEEE-488.2)
SCPI programming language 532xx Series and 53131A/53132A/53181A Series compatibility mode
Standard timebase aging (1-year, TCAL ±5 °C) ± 1 ppm (TCXO standard); ± 50 ppb (Option 010 Ultra-High Stability OCXO)
Warm-up time 45 minutes
Bench dimensions 261.1 mm W x 103.8 mm H x 303.2 mm D
Rack mount dimensions 212.8 mm W x 88.3 mm H x 272.3 mm D (2U x 1/2 width)
Weight 3.9 kg (8.6 lbs) fully optioned; 3.1 kg (6.9 lbs) without Option 300
Operating temperature 0 °C to +55 °C
Storage temperature -30 °C to +70 °C
Operating humidity 5% to 80% RH, non-condensing
Operating altitude Up to 3000 meters (10,000 ft)
Line power voltage 100 V - 240 V ± 10%, 50-60 Hz ± 5%; 100 V - 120 V, 400 Hz ± 10%
Power consumption 90 VA max when powered on or charging battery; 6 VA max when powered off/standby
Acoustic noise (nom) SPL 35 dB(A)
Important: Maximum input ratings: 50 Ω damage level is 1 W with internal protection that will not activate below 7.5 Vpk. The 1 MΩ damage level is 350 Vpk (AC+DC) from DC to 5 kHz, derating linearly to 10 Vpk above 100 kHz. Microwave channel damage levels: >+27 dBm for the 6 GHz Option 106, >+19 dBm for the 15 GHz Option 115.Important: When ordered with optional rear terminals (Option 201), the standard/baseband channel inputs are active on both the front and rear of the universal counter; however the specifications provided only apply to the rear terminals. Performance for the front terminals with rear terminals installed is not specified.Important: All probes used with this instrument must be compatible with a 20 pF input capacitance.Important: The 53210A provides RF frequency counting only. Time interval, pulse width, rise/fall time, duty cycle, phase, and totalize measurements are NOT available on the 53210A — these require the 53220A or 53230A.Important: Pulse/burst microwave measurements (carrier frequency, PRI, PRF, positive/negative width) are available only on the 53230A with Option 106 or Option 115 installed.Important: Continuous gap-free measurements and timestamp/modulation domain analysis are available only on the 53230A.Important: Microwave input options 106 (6 GHz) and 115 (15 GHz) are mutually exclusive; only one microwave channel option can be installed.Recommended pairing: when probing voltage signals at the standard channels, the Keysight N2870A (1:1, 35 MHz), N2873A (10:1, 500 MHz), or N2874A (10:1, 1.5 GHz) passive probes listed in the datasheet's recommended accessories match the counter's 20 pF input capacitance requirement.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Keysight

Condition

New

Manufacturer

Keysight

Frequency

350 MHz

10

Ultra High-stability OCXO Timebase

106

Add Channel 2 - 6 GHz CW

115

Add Channel 2 - 15 GHz CW

201

Add rear panel parallel input for Ch 1

203

Move Channel 2 input to rear panel - SMA

300

Internal lithium ion battery/charger for unstable AC power or timebase stability

A6J

ANSI Z540-1-1994 Calibration