Hioki CT6710 DC to 50 MHz Current Probe

Key Features At A Glance

  • Three current ranges — 30 A, 5 A, and 0.5 A — capture inrush, micro, and high-speed currents with one probe
  • Bandwidth spans DC to 50 MHz (CT6710) and DC to 120 MHz (CT6711) across the series
  • Output voltage rates of 0.1 V/A (30 A), 1 V/A (5 A), and 10 V/A (0.5 A range)
  • 10 V/A output in the 0.5 A range enables current display down to 100 µA/div on a 1 mV/div oscilloscope
  • One-touch auto-locking BNC connection requires no connector rotation when attaching to a scope or recorder
  • Built-in overload protection with a warning indicator that flashes when input exceeds the rated current
  • Measures insulated conductors up to φ5 mm in diameter
  • Powered by the Z5021 Probe Power Unit (up to four probes) or the optional 3269 Power Supply (up to two)
View full details

The CT6710 and CT6711 are clamp-style current probes from HIOKI built to capture inrush, micro, and high-speed currents with a single probe. Each model provides three selectable current ranges — 30 A, 5 A, and 0.5 A — so current can be analyzed across a broad span of operating conditions from one instrument, with the operating range chosen using the range keys on the relay box.

These probes support current-consumption and current-waveform analysis such as observing the current draw of a Bluetooth Low Energy device while it sends and receives data, capturing the inrush current that flows when an electrical device is switched on, and observing micro currents on the order of several hundred microamperes. They connect to oscilloscopes and to the Memory HiCorder MR6000 for these measurements.

ValueTronics, in business since 1992, stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

Compare Other Models in This Series

The CT6710/CT6711 form a two-model current-probe series that shares a common three-range architecture — 30 A, 5 A, and 0.5 A — and differs primarily in frequency range and rise time. Both models capture inrush, micro, and high-speed currents with a single probe and select their operating range from the relay box.

Within the series, the two probes share the same current ranges, output voltage rates (0.1 V/A, 1 V/A, and 10 V/A), maximum rated currents, and protective features, so the choice between them centers on the required bandwidth rather than current-handling capability.

Each new model below is its own product page with condition-matched pricing. Select the model whose frequency range and rise time match your measurement needs; the comparison table that follows summarizes how the probes differ.

The principal difference between the models is bandwidth: the CT6710 covers DC to 50 MHz while the CT6711 covers DC to 120 MHz. Rise time tracks that difference, at 7.0 ns or less for the CT6710 and 2.9 ns or less for the CT6711.

The models also differ in their susceptibility to external magnetic fields — under a DC or 60 Hz, 400 A/m field the CT6710 shows 20 mA or less of effect versus 5 mA or less for the CT6711. The comparison table below details these per-model values alongside the shared range, output-rate, and accuracy specifications.

Model Frequency Range Rise Time Current Ranges
CT6710 DC to 50 MHz 7.0 ns or less 30 A / 5 A / 0.5 A
CT6711 DC to 120 MHz 2.9 ns or less 30 A / 5 A / 0.5 A

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Frequency Characteristics
Frequency range DC to 50 MHz (-3 dB)
Rise time (10% to 90%) 7.0 ns or less
Delay time, 30 A range (relative to an input signal with a rising time of 1 ns) Typical 12 ns
Delay time, 5 A range Typical 12 ns
Delay time, 0.5 A range Typical 13 ns
Current & Output
Maximum rated current, 30 A range (note frequency derating for DC and sine waves) 30 A rms
Maximum rated current, 5 A range 5 A rms
Maximum rated current, 0.5 A range 0.5 A rms
Output voltage rate, 30 A range 0.1 V/A
Output voltage rate, 5 A range 1 V/A
Output voltage rate, 0.5 A range 10 V/A
Maximum peak current, 30 A range ±50 A peak (Maximum 2 sec input)
Maximum peak current, 5 A range ±7.5 A peak
Maximum peak current, 0.5 A range ±0.75 A peak (<10 MHz), ±0.3 A peak (≥10 MHz)
Amplitude Accuracy (DC or 45 to 66 Hz sine wave, within maximum peak current for each range)
30 A range ±3.0% rdg. ±1 mV, Typical ±1.0% rdg. ±1 mV (≤10 A rms)
5 A range ±3.0% rdg. ±1 mV, Typical ±1.0% rdg. ±1 mV
0.5 A range ±3.0% rdg. ±10 mV, Typical ±1.0% rdg. ±10 mV
Accuracy guarantee Accuracy guaranteed for 1 year; post-adjustment accuracy guaranteed for 6 months
General
Diameter of measurable conductors φ5 mm or less (insulated conductors)
Noise (0.5 A range, with a 20 MHz bandwidth instrument) 75 μA rms or less
Operating temperature and humidity range 0 to +40 ℃ (32 to 104 ℉), 80% RH or less (no condensation)
Effect of external magnetic fields (DC or 60 Hz input, 400 A/m magnetic field) 20 mA or less
Cord lengths Sensor cord: 1.5 m (59.6 in); Power cord: 1.0 m (39.37 in)
External dimensions — Sensor Approx. 155 mm (6.10 in) W × 18 mm (0.71 in) H × 26 mm (1.02 in) D
External dimensions — Junction box Approx. 45 mm (1.77 in) W × 120 mm (4.72 in) H × 25 mm (0.98 in) D
External dimensions — Termination unit Approx. 29 mm (1.14 in) W × 83 mm (3.27 in) H × 40 mm (1.57 in) D
Mass Approx. 370 g (13.1 oz)
Important: Caution: input currents that exceed the frequency derating for the 30 A range may cause measurement circuit damage before the protection function can operate.
Important: Refrain from use for at least 20 seconds after a maximum peak current input due to generated heat (30 A range, ±50 A peak, maximum 2 sec input).
Important: A built-in overload protection function and warning indicator guard against excessive input: if an incorrect range is selected and a current exceeding that range's rated current is input, the warning indicator flashes and the function protects the instrument from overheating damage.
Important: These current probes require a probe power source to operate: connect them to the Z5021 Probe Power Unit (up to four CT6710/CT6711 probes) or the 3269 Power Supply (up to two CT6710/CT6711 probes), ordered separately.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.