LI-325C Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI-325C is compliant with both RTCA DO-160 and MIL-STD 461. The LISN provides defined stable impedance and isolates the EUT from power source influences, thereby providing accurate and repeatable results. The LI-325C includes one pair of, separately housed, single-conductor networks, to be installed in series with each current-carrying conductor in a single- phase, dual-phase or DC power system. A second LI-325C pair can be used to accommodate 3-phase power systems (Wye or Delta configurations). The LI-325C is equipped with Superior Electric SUPERCON® shrouded sockets at the mains (power input) and EUT (power output) ports. The matching color-coded plugs for connection to the mains and EUT wiring are included. This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-325C is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current. All Com-Power LISNs are individually calibrated in compliance with the relevant requirements of RTCA DO-160 and MIL-STD 461. Impedance and Insertion Loss data is supplied with each unit, along with the calibration certificate.
Model No
LI-325C
Condition
New
Manufacturer
Com-Power
Current
25 A
Frequency
400 MHz