Skip to product information
1 of 1

Anritsu MS2723B 9 kHz to 13 GHz Handheld Spectrum Analyzer (Pre-Owned)

Anritsu MS2723B 9 kHz to 13 GHz Handheld Spectrum Analyzer (Pre-Owned)

Request a Quote

🎓 Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Anritsu MS2723B 9 kHz to 13 GHz Handheld Spectrum Analyzer (Pre-Owned)

Key Features At A Glance

  • 9 kHz to 13 GHz coverage in a 3.4 kg (7.5 lb) handheld with an 8.4-inch 800x600 display
  • >101 dB dynamic range at 2.4 GHz (2/3 TOI-DANL) and -159 dBm DANL, both in 1 Hz RBW (preamp on)
  • Internal preamplifier standard (100 kHz to 4 GHz); 1 Hz to 3 MHz resolution bandwidth
  • Detectors: Peak, Negative, Sample, Quasi-peak, and true RMS; limit lines up to 40 segments
  • 10/100 LAN (RJ48C), USB, external trigger, and 37.8 MHz IF output; remote access over Ethernet
  • Optional licensed signal analyzers: LTE, GSM/EDGE, W-CDMA/HSDPA, TD-SCDMA, CDMA/EV-DO, WiMAX
  • Optional GPS (Option 0031) gives <±25 ppb frequency accuracy and trace geo-tagging
  • Li-Ion battery ~2.5 hr operation, <5 min warm-up, -10 °C to 55 °C operating range
View full details

The Anritsu MS2723B is part of the Spectrum Master line of high performance handheld spectrum analyzers, covering 9 kHz to 13 GHz (usable to 0 Hz). Built for the wireless professional, it is designed to deliver the performance needed for demanding measurements in harsh RF and physical environments, packaged in a 3.4 kg (7.5 lb) instrument with an 8.4-inch 800 x 600 display.

Anritsu positions the Spectrum Master for spectrum monitoring, broadcast proofing, interference analysis, RF and microwave measurements, regulatory compliance, and Wi-Fi and wireless network measurements. Across these tasks it is intended to make fast and reliable measurements in the field.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit we sell is inspected and functionally verified in-house against its original specifications before it ships, while new units leave factory-sealed exactly as received. That combination of held stock and in-house verification lets buyers source the right instrument with confidence in its condition.

Accessories Supplied

  • 10580-00207 Spectrum Master User Guide (includes Bias-Tee and GPS Receiver)
  • 2300-498 MST CD: Master Software Tools, User/Measurement Guides, Programming Manual, Troubleshooting Guides, Application Notes
  • 65729 Soft Carrying Case
  • 64343 Tilt Bail Stand Accessory
  • 633-44 Rechargeable Li-Ion Battery
  • 40-168-R AC/DC Power Supply
  • 806-141-R Automotive Cigarette Lighter 12 Volt DC Adapter
  • 3-806-152 Cat 5e Crossover Patch Cable, 7 feet/213 cm
  • 2000-1371-R Ethernet Cable, 7 feet/213 cm
  • 3-2000-1498 USB A-mini B Cable, 10 feet/305 cm
  • 2000-1520-R USB Memory Drive
  • 1091-27-R Type-N male to SMA female adapter
  • 1091-172 Type-N male to BNC female adapter

Product Core & Specifications

Specification Value
Frequency
Frequency Range 9 kHz to 13 GHz (usable to 0 Hz), Preamp 100 kHz to 4 GHz
Tuning Resolution 1 Hz
Frequency Reference Aging ± 1.0 ppm/10 years
Frequency Reference Accuracy ± 0.3 ppm (25 °C ±25 °C) + aging
Frequency Span 10 Hz to 13 GHz including zero span
Span Accuracy Same as frequency reference accuracy
Sweep Time 10 µs to 600 seconds in zero span, autoset in non-zero span
Sweep Time Accuracy ± 2% in zero span
Bandwidth
Resolution Bandwidth (RBW) 1 Hz to 3 MHz in 1–3 sequence ± 10% (1 MHz max in zero-span) (–3 dB bandwidth)
Video Bandwidth (VBW) 1 Hz to 3 MHz in 1–3 sequence (–3 dB bandwidth)
RBW with Quasi-Peak Detection 200 Hz, 9 kHz, 120 kHz (-6 dB bandwidth)
VBW with Quasi-Peak Detection Auto VBW is On, RBW/VBW = 1
Spectral Purity — SSB Phase Noise
@ 10, 20 and 30 kHz offset from carrier –95 dBc/Hz
@ 100 kHz offset from carrier –97 dBc/Hz
@ 1 MHz offset from carrier –105 dBc/Hz
@ 10 MHz offset from carrier –120 dBc/Hz
Amplitude Ranges
Dynamic Range > 101 dB @ 2.4 GHz, 2/3 (TOI-DANL) in 1 Hz RBW
Measurement Range DANL to +30 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Reference Level Range –120 dBm to +30 dBm
Attenuator Resolution 0 to 65 dB, 5.0 dB steps
Amplitude Units (Log Scale) dBm, dBV, dBmv, dBμV
Amplitude Units (Linear Scale) nV, μV, mV, V, kV, nW, μW, mW, W, kW
Amplitude Accuracy (single sine wave input < Ref level, > DANL, auto attenuation, 50 Ω Source)
20 °C to 30 °C ± 1.3 dB, after 30 minute warm-up; > 4 GHz add ± 1.4 dB
–10 °C to 50 °C Add ± 1.2 dB, after 60 minute warm-up
Displayed Average Noise Level (DANL) (RMS detection, 1 Hz RBW, 0 dB attenuation)
Preamp Off, 10 MHz to 4 GHz –139 dBm
Preamp Off, > 4 GHz to 10 GHz –136 dBm
Preamp Off, > 10 GHz to 13 GHz –130 dBm
Preamp Off, > 13 GHz to 20 GHz –136 dBm
Preamp On, 10 MHz to 1 GHz –159 dBm
Preamp On, > 1 GHz to 3 GHz –156 dBm
Preamp On, > 3 GHz to 4 GHz –154 dBm
Spurs
Residual Spurs, Preamp Off (RF input terminated, 0 dB input attenuation) –90 dBm
Residual Spurs, Preamp On (RF input terminated, 0 dB input attenuation) –100 dBm
Input-Related Spurious (0 dB attenuation, –30 dBm input, span < 1.7 GHz, carrier offset > 4.5 MHz) –60 dBc, –70 dBc typical
Input-Related Spurious Exceptions –50 dBc @ 3275 MHz
Third-Order Intercept (TOI) (–20 dBm tones 100 kHz apart, –20 dBm Ref level, 0 dB input attenuation, preamp Off)
2.4 GHz +12 dBm
50 MHz to 500 MHz > +6 dBm typical
> 500 MHz to 2000 MHz > +8 dBm typical
> 2000 MHz to 6000 MHz > +10 dBm typical
> 6000 MHz to 20000 MHz > +12 dBm typical
Second Harmonic Distortion (Preamp Off)
50 MHz to 500 MHz –50 dBc
> 500 MHz to 800 MHz –45 dBc
> 800 MHz to 3000 MHz –60 dBc
> 3000 MHz –80 dBc
VSWR
> 10 dB input attenuation 1.5:1 typical
General — Input
Maximum Continuous Input (≥ 10 dB input attenuation) +30 dBm
Input Damage Level ≥ 10 dB input attenuation, > +30 dBm, ± 50 Vdc
ESD Damage Level (≥ 10 dB input attenuation) > 10 kV
External Reference Frequencies 1 MHz, 1.2288 MHz, 1.544 MHz, 2.048 MHz, 2.4576 MHz, 4.8 MHz, 4.9152 MHz, 5 MHz, 9.8304 MHz, 10 MHz, 13 MHz and 19.6608 MHz at –10 dBm to +10 dBm
Memory
Internal Trace/Setup Memory > 13,000 traces
External Trace/Setup Memory Limited by size of USB Flash drive or Compact Flash module
Connectors
RF In Type N, female, 50 Ω, Maximum Input + 30 dBm, ± 50 VDC
GPS BNC, female, reverse polarity
External Power 5.5 mm barrel connector, 12 to 15 VDC, < 5.0 Amps
LAN Connection RJ48C, 10/100 Mbps, Connect to PC or LAN for Remote Access
Compact Flash Interface Type I
USB Interface Type A, Connect Flash Drive and Power Sensor
USB Interface 5-pin mini-B, Connect to PC for data transfer
Headset 2.5 mm miniature phone plug
External Trigger In BNC, female, 50 Ω, Maximum Input ± 5 VDC
IF Out BNC, female, 50 Ω, 37.8 MHz
Display
Size 8.4"
Resolution 800 x 600
Battery
Type Li-Ion
Battery Operation 2.5 hours, typical
Electromagnetic Compatibility
European Union CE Mark, EMC Directive 89/336/EEC, 92/31/EEC, 93/68/EEC and Low Voltage Directive 73/23/EEC, 93/68/EEC
Australia and New Zealand C-tick N274
Interference EN 61326-1
Emissions EN 55011
Immunity EN 61000-4-2/-4-3/-4-4/-4-5/-4-6/-4-11
Safety
Safety Class EN 61010-1 Class 1
Product Safety IEC 60950-1 when used with Company supplied Power Supply
Environmental
Operating Temperature –10 ºC to 55 ºC
Maximum Humidity 85%
Shock MIL-PRF-28800F Class 2
Storage –51 ºC to 71 ºC
Important: Maximum continuous input: +30 dBm (≥10 dB input attenuation). Input damage level: >+30 dBm, ±50 VDC.
Important: High Accuracy Power Meter (Option 0019) requires external USB Power Sensor(s) — sensors (PSN50, MA24104A, MA24106A, MA24108A, MA24118A, MA24126A) are ordered separately.
Important: Options marked with a single asterisk (0040, 0041, 0044, 0045, 0065, 0060, 0061, 0038, 0541, 0542, 0546, 0042, 0043, 0062, 0063, 0046, 0047, 0066, 0067) require Option 0009 (I/Q Demodulation Hardware).
Important: W-CDMA/HSDPA Over-the-Air (Option 0035) and cdmaOne/CDMA2000 1X Over-the-Air (Option 0033) and CDMA2000 1xEV-DO Over-the-Air (Option 0034) require Option 0009 and Option 0031 (GPS Receiver).
Important: Recommended calibration cycle is 12 months.
Important: Product Safety (IEC 60950-1) applies only when used with the Company supplied Power Supply.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • ValueTronics warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Anritsu

Condition

Pre-Owned

Manufacturer

Anritsu

Spec_ana_freq

9 kHz to 13 GHz

19

High Accuracy Power Meter

25

Interference Analyzer

31

GPS Receiver Option

43

13.5 GHz Signal Analyzer