Key Features At A Glance

  • Frequency coverage from 100 kHz to 7.1 GHz with a standard built-in preamplifier
  • Ethernet 10/100 Base-T and USB 2.0 connectivity; SCPI remote programming via Ethernet
  • 100 dB dynamic range with +29 dBm third order intercept for linear component measurements
  • DANL of –150 dBm (preamp on) and –126 dBm (preamp off) at RBW = 10 Hz
  • Typical –110 dBc/Hz SSB phase noise at 10 kHz offset up to 6 GHz
  • 8 MHz capture bandwidth, True RMS detection, and 65 dB attenuation range in 5 dB steps
  • Optional WCDMA/HSDPA and WCDMA demodulation measurements (field options, require Option 009)
  • 20 W (+43 dBm) input protection with +30 dBm maximum continuous input
View full details

The Anritsu MS2717A is an economy-class spectrum analyzer covering 100 kHz to 7.1 GHz. It delivers spectrum analysis with a standard built-in preamplifier, a 100 dB dynamic range, and WCDMA signal analysis capability, packaged in an ergonomically designed instrument intended to lower the cost of testing while retaining the performance engineers expect from the category.

A spectrum analyzer displays the amplitude of signals across a frequency range, letting an engineer characterize signal levels, harmonics, and modulation quality in the frequency domain. The MS2717A is positioned for spectrum analysis of wireless components in the physical layer of communication systems: its phase noise performance measures wireless local oscillators and synthesizers, its dynamic range supports linear measurements of wireless components, and its 8 MHz capture bandwidth supports optional WCDMA/HSDPA and WCDMA demodulator measurements for testing Node-B transmitters. It is designed for use in manufacturing, R&D, and general purpose testing.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house against the manufacturer's specifications before it ships, while new units ship factory-sealed exactly as received. That combination lets buyers source instruments like the MS2717A with confidence in both availability and verified condition.

Accessories Supplied

  • 10580-00159 Anritsu User's Guide, Model MS2717A
  • 2300-498 CD ROM containing Master Software Tools
  • 2000-1360 USB A-mini B cable
  • 2000-1371 RJ45 Ethernet Cable
  • 2000-1358 64 MB Compact Flash
  • Certificate of Calibration and Conformance

Product Core & Specifications

Specification Value
Frequency
Frequency Range 100 kHz to 7.1 GHz
Frequency Span 10 Hz to 7.1 GHz plus 0 Hz (zero span)
Tuning Resolution 1 Hz
Typical Dynamic Range (Offset = 100 kHz / 15 MHz, RBW = 10 Hz)
900 MHz 100 dB / 103 dB
1900 MHz 100 dB / 104 dB
2300 MHz 100 dB / 104 dB
2500 MHz 97 dB / 103 dB
2700 MHz 98 dB / 104 dB
3500 MHz 99 dB / 101 dB
5800 MHz 94 dB / 100 dB
Third Order Intercept, Typical (Offset = 100 kHz)
50 MHz to 300 MHz >8 dBm
>300 MHz to 2.2 GHz >10 dBm
>2.2 to 2.8 GHz >15 dBm
>2.8 to 4.0 GHz >10 dBm
>4.0 to 7.1 GHz >13 dBm
Typical TOI for Popular Frequencies (Offset = 100 kHz / 15 MHz)
900 MHz 13 dBm / 18 dBm
1900 MHz 17 dBm / 24 dBm
2300 MHz 20 dBm / 27 dBm
2500 MHz 20 dBm / 29 dBm
2700 MHz 20 dBm / 30 dBm
3500 MHz 16 dBm / 20 dBm
5800 MHz 13 dBm / 23 dBm
DANL, Preamplifier On (RBW = 10 Hz, Typical / Max)
10 MHz to 1.0 GHz –155 dBm / –151 dBm
>1.0 to 2.2 GHz –152 dBm / –149 dBm
>2.2 to 2.8 GHz –147 dBm / –143 dBm
>2.8 to 4.0 GHz –150 dBm / –149 dBm
>4.0 to 6.5 GHz –150 dBm / –144 dBm
>6.5 to 7.1 GHz –149 dBm / –144 dBm
DANL, Preamplifier Off (RBW = 10 Hz, Typical / Max)
10 MHz to 1.0 GHz –135 dBm / –127 dBm
>1.0 GHz to 2.2 GHz –130 dBm / –123 dBm
>2.2 to 2.8 GHz –125 dBm / –116 dBm
>2.8 to 4.0 GHz –130 dBm / –126 dBm
>4.0 to 6.5 GHz –127 dBm / –117 dBm
>6.5 to 7.1 GHz –121 dBm / –117 dBm
Noise Figure (Typical, 0 dB attenuation, 23ºC, preamplifier on)
10 MHz to 1.0 GHz 9 dB
>1.0 to 2.2 GHz 12 dB
>2.2 to 2.8 GHz 17 dB
>2.8 to 4.0 GHz 14 dB
>4.0 to 6.5 GHz 14 dB
>6.5 to 7.1 GHz 15 dB
Second Harmonic Distortion (0 dB input attenuation, –30 dBm input)
50 MHz to 750 MHz –50 dBc
>750 MHz to 1.05 GHz –40 dBc
>1.05 to 1.4 GHz –50 dBc
>1.4 to 2 GHz –70 dBc
>2 GHz –80 dBc
Amplitude
Maximum Continuous Input (≥10 dB attenuation) +30 dBm
Input Damage Level (≥10 dB attenuation) >+43 dBm, ± 50 Vdc
Input Damage Level (<10 dB attenuation) >+23 dBm, ± 50 Vdc
ESD Damage Level (≥10 dB attenuation) >10 kV
Amplitude Accuracy (20°C to 30°C)
Overall Amplitude Accuracy (95%), 0 dBm to –50 dBm, preamplifier off, 10 dB attenuation ±0.9 dB <3 GHz; ±1.25 dB <7.1 GHz
Amplitude Accuracy at 50 MHz ±0.8 dB
Frequency Flatness ±0.5 dB <3 GHz; ±1.0 dB <7.1 GHz
Phase Noise at 800 MHz (Guaranteed / Typical SSB <6 GHz)
10 kHz offset <–100 dBc/Hz / –110 dBc/Hz
20 kHz offset <–100 dBc/Hz / –110 dBc/Hz
30 kHz offset <–100 dBc/Hz / –110 dBc/Hz
100 kHz offset <–102 dBc/Hz / –112 dBc/Hz
Time Base Stability
Aging < ±1 x 10-6/yr or 1 ppm/yr
Accuracy (25º C ± 25º C), Standard < ±1 x 10-6/yr or 1 ppm/yr + long term drift
Accuracy (25º C ± 25º C), Option 9 < ±0.3 x 10-6/yr or 0.3 ppm/yr + long term drift
Span Accuracy Same as frequency reference accuracy
Amplitude / Bandwidth Settings
Attenuator Range 0 to 65 dB
Attenuator Resolution 5 dB steps
Measurement Range DANL to +30 dBm
Display Range 1 to 15 dB/div in 1 dB steps, ten divisions displayed
Resolution Bandwidth (–3 dB width) 10 Hz to 3 MHz
Resolution Bandwidth steps 1-3 sequence ±10%
Video Bandwidth (–3 dB) 1 Hz to 3 MHz
Video Bandwidth steps 1-3 sequence
Demodulation Bandwidth 8 MHz
Sweep Times
Sweep Time Minimum 200 ms, adjustable to 10 µs in zero span
Sweep Time Accuracy ±2% in zero span
Sweep Trigger Free run, Single, Video, External
Sweep Span Full span, zero span, and span up/span down
6 GHz span (RBW 3 MHz, VBW 1 MHz) 1.1 secs
200 MHz span (RBW 300 kHz, VBW 100 kHz) 200 ms
10 MHz span (RBW 30 kHz, VBW 10 kHz) 200 ms
1 MHz span (RBW 3 kHz, VBW 1 kHz) 90 ms
200 kHz span (RBW 3 Hz, VBW 3 MHz) 99 ms
2.2 kHz span (RBW 10 Hz, VBW 3 Hz) 149 ms
Spurious
Input-Related Spurious (–30 dBm input, 0 dB attenuation) –60 dBc max
Residual Spurious, Preamplifier Off (100 kHz to 3.2 GHz) –90 dBm max
Residual Spurious, Preamplifier Off (>3.2 GHz to 7.1 GHz) –84 dBm max
Residual Spurious, Preamplifier On (100 kHz to 7.1 GHz) –100 dBm max
General
Detection Peak, Negative, Sample, RMS
Displayed Traces Three traces with trace overlay; one trace is always live data, two traces can be either stored data or mathematically manipulated traces
Memory Standard 64 MB Compact Flash card, greater than 1000 traces and 1000 setups
Important: Maximum continuous input: +30 dBm (≥10 dB attenuation). Input damage level: >+43 dBm, ±50 Vdc with ≥10 dB attenuation.
Important: Option 044 (WCDMA/HSDPA RF Measurements) and Option 045 (WCDMA Demodulator) require Option 009 (Modulation Measurement and Demodulation Hardware Upgrade), which provides upgrades to the microprocessor, timebase, and FIFO memory.
Important: Optional ACLR (Adjacent Channel Leakage Ratio) measurements require connection to Anritsu's MG3700A Vector Signal Generator.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Anritsu

Condition

Pre-Owned

Manufacturer

Anritsu

Spec_ana_freq

100 kHz to 7.1 GHz