Key Features At A Glance

  • Output power up to 1560 W in a compact 1U rackmountable package across seven voltage/current configurations
  • Programmable voltage and current slew rate for soft-starting sensitive loads
  • List mode executes test sequences with up to 150 steps from instrument memory
  • USB and RS485 standard; LAN and GPIB available on -GL models for ATE integration
  • Average command processing time under 50 ms for responsive automated test sequencing
  • Daisy-chain up to 30 units via RS485 from a single master PC, or operate up to four units in master/slave parallel (all models) or series (high-current models only)
  • Extensive protection: OVP, OCP, OPP, OTP, foldback protection mode, and key-lock function
  • SCPI-compliant command set with LabVIEW drivers and application software included
View full details

The B&K Precision XLN Series is a family of programmable single-output DC power supplies delivering up to 1560 W of clean power in a compact 1U rackmountable package. The series spans seven models covering high-current configurations from 0–36 V at 40 A through 0–100 V at 14.4 A, and high-voltage configurations from 5–150 V at 10.4 A through 5–600 V at 2.6 A. Unlike comparable system supplies that primarily address the ATE market, the XLN series is designed to serve both benchtop users and system integrators in a single platform.

According to the datasheet, the XLN series is suited for ATE systems integration, product design and development, product QC and burn-in testing, and other applications requiring excellent regulation, high power, low noise, and a wide range of voltage and current ratings. The current-flow timer feature enables accurate measurement of fuse or circuit breaker opening times, with resolution to the nearest 100 microseconds and a maximum counting period of one hour.

Brand Heritage

B&K Precision Corporation is a long-established U.S.-based manufacturer of electronic test and measurement instruments. The company has operated under the B&K Precision name through its modern history and continues to release new test instrument families, including the XLN Series of programmable DC power supplies covered in this datasheet.

Compare Other Models in This Series

The XLN Series spans seven models organized into two configuration groups: four high-current models (XLN3640, XLN6024, XLN8018, XLN10014) delivering 1440 W in output ranges from 0–36 V/40 A through 0–100 V/14.4 A, and three high-voltage models (XLN15010, XLN30052, XLN60026) delivering 1560 W in output ranges from 5–150 V/10.4 A through 5–600 V/2.6 A. Each model is available with standard USB and RS485 interfaces, or in a -GL variant that adds LAN and GPIB.

Beyond the output voltage and current envelope, the two configuration groups differ in feature set. High-current models include a fixed 5 V / 1 A auxiliary output, 1 mV / 1 mA display resolution, and support master/slave operation in both parallel and series configurations. High-voltage models offer 10 mV / 1 mA display resolution, master/slave parallel operation only, and add analog monitoring outputs alongside the analog programming interface.

Each new XLN model below is listed on its own product page with condition-matched pricing, configuration details, and current availability. Select the model that matches the voltage and current envelope your application requires.

The primary axis of differentiation across the XLN Series is the output voltage and current envelope, which determines the application class the model is built for. The four high-current models sit at 1440 W and target lower-voltage, higher-current applications. The three high-voltage models sit at 1560 W and target higher-voltage, lower-current applications including testing of higher-voltage power electronics, batteries, and electric vehicle subsystems.

Programming and readback resolution, ripple and noise, OVP adjustment range, transient response, and remote sense compensation also scale with model. The comparison table that follows summarizes the headline specifications side by side so the correct model for a given output envelope can be confirmed at a glance.

Model Output Voltage Output Current Output Power
XLN10014-GL 0-100 V 0-14.4 A 1440 W
XLN3640 0-36 V 0-40 A 1440 W
XLN3640-GL 0-36 V 0-40 A 1440 W
XLN6024 0-60 V 0-24 A 1440 W

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cord
  • Rackmount kit
  • Test report & certificate of calibration
  • Terminal blocks for output connectors

Product Core & Specifications

Specification XLN3640 XLN6024 XLN8018 XLN10014 XLN15010 XLN30052 XLN60026
Output Rating
Output Voltage 0-36 V 0-60 V 0-80 V 0-100 V 5-150 V 5-300 V 5-600 V
Output Current 0-40 A 0-24 A 0-18 A 0-14.4 A 0.04-10.4 A 0.02-5.2 A 0.01-2.6 A
Output Protection
OVP Adjustment Range 2-38 V 3-64 V 4-85 V 5-105 V 5-158 V 5-315 V 5-630 V
OVP Accuracy 200 mV 300 mV 400 mV 500 mV 750 mV 1.5 V 3 V
Line Regulation
Voltage ≤ 4 mV ≤ 6 mV ≤ 8 mV ≤ 10 mV ≤ 17 mV ≤ 32 mV ≤ 62 mV
Current ≤ 4 mA ≤ 4 mA ≤ 4 mA ≤ 4 mA ≤ 20.8 mA ≤ 10.4 mA ≤ 5.2 mA
Load Regulation
Voltage ≤ 8 mV ≤ 8 mV ≤ 10 mV ≤ 12 mV ≤ 17 mV ≤ 32 mV ≤ 62 mV
Current ≤ 8 mA ≤ 7 mA ≤ 6.5 mA ≤ 6 mA ≤ 40.4 mA ≤ 20.8 mA ≤ 10.4 mA
Ripple and Noise (20 Hz-20 MHz)
Normal Mode Voltage (Load ≥ 0.5% of max load) ≤ 5 mVrms / ≤ 60 mVpp ≤ 6 mVrms / ≤ 70 mVpp ≤ 7 mVrms / ≤ 80 mVpp ≤ 8 mVrms / ≤ 80 mVpp ≤ 10 mVrms / ≤ 100 mVpp ≤ 25 mVrms / ≤ 150 mVpp ≤ 50 mVrms / ≤ 300 mVpp
Normal Mode Current ≤ 90 mA ≤ 70 mA ≤ 50 mA ≤ 40 mA ≤ 15 mA ≤ 10 mA ≤ 5 mA
Programming Resolution
Programming & Readback 1 mV / 1 mA 1.5 mV / 1 mA 2 mV / 1 mA 2.5 mV / 1 mA 10 mV / 1 mA
Programming and Readback Accuracy ±(% output+offset)
Voltage 0.05% + 10 mV 0.05% + 15 mV 0.05% + 20 mV 0.05% + 25 mV 0.05% + 75 mV 0.05% + 150 mV 0.05% + 300 mV
Current 0.05% + 10 mA 0.05% + 18 mA 0.05% + 7 mA 0.05% + 6 mA 0.1% + 30 mA 0.1% + 15.6 mA 0.1% + 7.8 mA
General
Average Command Response Time ≤ 50 ms
Power Factor Correction (PFC) ≥ 0.99 (Full load)
Efficiency ≥ 80% (Full load)
Remote Sense Compensation 2 V 5 V
Rise Time at Full Load ≤ 15 ms ≤ 20 ms ≤ 25 ms ≤ 30 ms ≤ 100 ms
Rise Time at No Load ≤ 15 ms ≤ 20 ms ≤ 25 ms ≤ 30 ms ≤ 100 ms
Fall Time at Full Load ≤ 15 ms ≤ 20 ms ≤ 25 ms ≤ 30 ms ≤ 100 ms
Fall Time at No Load ≤ 1000 ms ≤ 1000 ms ≤ 2000 ms ≤ 3000 ms
Transient Response Time ≤ 1 ms ≤ 2 ms
AC Line Rated Input Voltage/Hz 100-240 VAC / 47 Hz-63 Hz
Tolerance/Variation in Voltage -15% to +10% (10% power de-rating mode when voltage under 95 VAC)
Maximum Rated Input Power 1700 VA 1950 VA
Temperature Ratings Operation (0 °C - 40 °C) / Storage (-10 °C - 70 °C)
Standard Interface USB, RS485, analog interface
Optional Interface LAN, GPIB
Dimensions (W x H x D) 16.5" x 1.72" x 17" (420 x 43.6 x 432 mm) 16.5" x 1.74" x 18.1" (420 x 44.2 x 460 mm)
Important: Master/slave series operation is supported on high-current XLN models only. High-voltage XLN models support master/slave parallel operation only.Important: Auxiliary 5 V / 1 A output is available on high current models (XLN3640, XLN6024, XLN8018, XLN10014) only; high voltage models (XLN15010, XLN30052, XLN60026) do not include this output.Important: Master/Slave series operation is supported on high current models only. High voltage models support parallel master/slave operation only.Important: Analog monitoring is available on high voltage models only.Important: Output terminal block connectors are included with high current models only.Important: GPIB and LAN interfaces are optional and available only on -GL version models.Recommended pairing: when daisy-chaining multiple XLN units via RS485, use the master unit's USB, GPIB, or LAN interface for PC control of up to 30 supplies from a single host.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

B&K

Condition

New

Manufacturer

B&K Precision

Current

14.4 A

Voltage

100 V

Power

1.44 kW