Skip to product information
1 of 1
Used
lab tested

8590L Agilent Spectrum Analyzer Used

8590L Agilent Spectrum Analyzer Used

Shipping calculated at checkout.
Calibrations
check availability
Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Additional Features:

  • Frequency range: 9 kHz-1.8 GHz
  • Eliminate the need for a separate frequency counter with the built-in frequency counter-with ±2.1 kHz accuracy at 1 GHz (±7.6 kHz from 0 to 50 °C)
  • Multiple resolution bandwidth filters: Optimize the tradeoffs of speed, sensitivity and the separation of closely spaced signals with your choice of 10 resolution bandwidth filters beginning at 1 kHz
  • 145 dB amplitude measurement range: Measure signals directly with -115 dBm to +30 dBm amplitude measurement range
  • One-button measurement routines: Save time, setup, and training with one button measurement routines such as Adjacent Channel Power, signal bandwidth and Third Order Intercept (TOI)
  • Phase noise of 105 dBc/Hz at 30 kHz offset: Uncover small signals close to carriers with an internal phase noise that will not get in your way
  • Dual interfaces: Operate remotely and print directly with the optional dual interfaces that combine either an GP-IB or RS-232 port with a parallel (Centronics) port
Share on
View full details

The Agilent 8590L Spectrum Analyzer is designed to meet your general purpose measurement needs. The easy-to-use interface provides access to more than 200 built-in functions.

The Agilent 8590L has an optional built-in tracking generator that measures the scalar characteristics of your components with the optional built-in tracking generator and the Agilent 85714A scalar measurements personality.

Data storage can be to internal memory, where over 50 traces and states may be saved, or to memory cards through the optional memory-card reader. Data can be directly output to a printer or plotter through the optional GPIB, RS-232, or parallel printer interfaces.

Built-in Measurement Capability

Third-order intercept, percent AM, and “N” dB bandwidth are just a few of the built-in measurements. These measurements are performed at the press of a single softkey. Results are displayed onscreen. And the downloadable program (DLP) capability lets you write your own built-in measurements using the DLP editor and an external keyboard.

Measurement Personalities

Measurement personalities are application-specific DLPs that are loaded into the analyzer through the optional card reader. They provide measurement routines and a user-interface specific to the application. A scalar measurements personality customizes the 8590L with optional built in 1.8 GHz tracking generator, and a cable TV measurements personality equips the 8590L-Series with one-button RF measurements for CATV service and system monitoring.

MIL-T-28800 Conformance

The 8590 series spectrum analyzers conform to the environ-mental specifications of MIL-T-28800 class 5 to insure reliable and accurate performance in portable environments as well as indoors. Compliance with the MIL-T-28800 standards of vibration, temperature, humidity, and shock provide assurance that the 8590 series will withstand the rigors of field use.

Model No

8590L

Condition

Used

Manufacturer

Agilent

Frequency

1.8 GHz

1

75 Ohm Input Impedance

3

Memory Card Reader

4

Precision Frequency Reference

9

LO and Sweep + Tune Outputs on Rear Panel

10

9 kHz to 2.9 GHz Tracking Generator with 50 Ohm output impedance

11

9 kHz to 2.9 GHz Tracking Generator with 75 Ohm output impedance

15

Protective Tan Operating/Carrying Case with Shoulder Strap

16

Protective Yellow Operating/Carrying Case with Shoulder Strap

21

HP-IB Interface

23

RS-232 Interface

26

Frequency Extension to 26.5 GHz with APC-3.5 Connector

27

Frequency Extension to 26.5 GHz with N-Type Connector

41

HP-IB and Parallel Interface

42

Protective Soft Carrying Case/Back Pack

43

RS-232 and Parallel Interface

50

Improved Amplitude Accuracy for NADC bands

51

Improved Amplitude Accuracy for PDC bands

52

Improved Amplitude Accuracy for PHS

53

Improved Amplitude Accuracy for CDMA

0B0

No manuals

101

Fast Time Domain Sweeps

102

AM/FM Demodulator with Speaker and TV Sync Trigger Circuitry

103

Quasi-Peak Detector and AM/FM Demodulator With Speaker

105

Time-Gated Spectrum Analysis

110

CT2 Demodulator

111

Group Delay and Amplitude Flatness

112

DECT Demodulator

119

Noise Figure

130

Narrow Resolution Bandwidths

140

Narrow Resolution Bandwidths and Precision Frequency Reference

151

DSP , Fast ADC and Digital Demodulator

160

PDC/PHS/NADC/CDMA Firmware for Option 151

161

NADC-TDMA firmware ROM for Option 151

163

GSM/DCS1800 Firmware for Option 151

180

TV Picture Display

301

TV Sync Trigger Capability/Fast Time-Domain Sweeps and AM/FM Demodulator

40

Front cover w/ storage

711

500 to 75 Ohm Matching Pad

713

Reduced Frequency Accuracy

8ZE

Refurbished spectrum analyzer

908

Rack Mount Kit Without Handles

909

Rack Mount Kit With Handles

B70

BenchLink Spectrum Analyzer

H01

Unlisted custom house option

J66

Improved Absolute Amplitude Accuracy Specification of +/-1dB in PCS 1900

R53

Improved Amplitude Accuracy for CDMA-Retrofit kit

UK6

Commercial Calibration Certificate with Test Data