Key Features At A Glance

  • Frequency range 9 kHz to 3 GHz with digital frequency processing
  • 16 digitally implemented resolution bandwidths from 200 Hz to 1 MHz (1, 2, 3, 5 sequences)
  • Displayed average noise level typ. -120 dBm (300 Hz RBW) for detecting weak signals
  • Built-in frequency counter with 1 Hz resolution
  • Maximum input level up to +33 dBm (50 MHz to 3 GHz)
  • Remote control via USB interface with supplied Windows 2000/XP driver
  • 5.4-inch active TFT colour display, 320 x 240 pixels
  • Level measurement uncertainty <=1.5 dB
View full details

The R&S FS300 is a spectrum analyzer covering a frequency range of 9 kHz to 3 GHz. Using a modern, digital frequency processing technique, it delivers high measurement quality at a favourable price. It is built as a versatile instrument for comprehensive measurements on the lab bench, in service, and as a flexible measuring instrument in automatic production systems.

The instrument addresses several measurement applications: measurement of RF spectrum (level and frequency), measurement of radiated interference (EMC), time-domain measurement, and radiomonitoring remote-controlled via USB. Operation is menu-guided with clear menu structures, so that even untrained users can quickly obtain correct results, while users already familiar with Rohde & Schwarz spectrum analyzers will recognize the menu items from other Rohde & Schwarz instruments.

ValueTronics keeps its inventory under its own roof, holding and stocking equipment in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every pre-owned unit is inspected and functionally verified in-house before it ships, while new units are shipped factory-sealed exactly as received from the manufacturer.

Accessories Supplied

  • Windows 2000/XP-compatible USB driver

Product Core & Specifications

Specification Value
Frequency
Frequency range 9 kHz to 3 GHz
Reference frequency, Aging 2 x 10–6 / year
Reference frequency, Temperature drift 1 x 10–6 (5° C to 30° C)
Frequency counter, Resolution 1 Hz, 10 Hz, 100 Hz, 1 kHz
Frequency span 1 kHz to 3 GHz, 0 Hz
Spectral purity
SSB phase noise (10 kHz carrier offset) <–90 dBc (1 Hz)
Residual FM (1 kHz resolution bandwidth, 1 kHz video bandwidth) <100 Hz, typ. 60 Hz
Sweep time
Span ≥ 1 kHz 100 ms to 1000 s
Span = 0 Hz 100 µs to 20 s
Bandwidths
Resolution bandwidths (–3 dB) 200 Hz to 1 MHz in 1, 2, 3, 5 sequences
Video bandwidths 10 Hz to 1 MHz in 1, 2, 3, 5 sequences
Amplitude
Level measurement range >137 dB
Max. input level, 50 MHz to 3 GHz +33 dBm
Max. input level, 10 MHz to 50 MHz +26 dBm
Max. input level, 9 kHz to 10 MHz +20 dBm
Intermodulation-free range, 1 MHz to 100 MHz (two-tone signal with 2 x –30 dBm, 6 dB input attenuation) ≤ –60 dBc
Intermodulation-free range, 100 MHz to 3 GHz ≤ –70 dBc
Harmonics (–40 dBm, 0 dB input attenuation) ≤ –60 dBc
Inherent spurious responses (terminated input, 0 dB input attenuation) ≤ –85 dBm
Other spurious (10 MHz to 3 GHz, –30 dBm level at first mixer) ≤ –60 dBc
Displayed average noise level (300 Hz resolution bandwidth, 10 Hz video bandwidth, 0 dB input attenuation) ≤ –110 dBm, typ. –120 dBm
1 dB compression point of first mixer (100 kHz to 3 GHz, 0 dB input attenuation) –10 dBm
Setting range of reference level –110 dBm to +36 dBm
RF input attenuation range 0 dB to 70 dB in 2 dB steps, manual selection or automatic coupling to reference level
Display range 80 dB, 40 dB, 16 dB, 8 dB, linear
Display units, Logarithmic dBm, dBµV, dBmV
Display units, Linear V, W
Traces 1 active trace and 1 stored trace
Level measurement uncertainty ≤1.5 dB
Markers
Marker 1 marker and 1 delta marker
Marker functions peak, next peak, marker to center, marker to reference
Marker display normal, delta, noise marker, frequency counter
Trigger free run, video, external, line
Inputs
RF input, Connector N female
Input impedance 50 Ω
VSWR (10 MHz to 3 GHz, input attenuation ≥ 20 dB) <1.5
Max. input level (with 30 dB input attenuation) +33 dBm
Max. DC voltage 30 V
External trigger input, Connector BNC female
Trigger voltage TTL voltages
Reference frequency input, Connector BNC female
Reference frequency 10 MHz ± 50 Hz
Input voltage 0.5 V to 2 V at 50 Ω
Output
Reference frequency output, Connector BNC female
Reference frequency 10 MHz
Output voltage >0.5 V at 50 Ω
Interfaces
USB-Host, Connector A plug
USB-Host, Protocol Version 1.1
USB-Host, Command set device-specific, remote control via supplied Windows driver (Windows XP, 2000)
USB interface, Connector B plug
USB interface, Protocol Version 1.1
General data
Display, Type 5.4" active TFT colour display
Display, Resolution 320 x 240 pixels
Memory locations, Traces 5
Memory locations, Device setups 10
Permissible temperature range (meets DIN EN 60068-2-1/2) +5° C to +45° C
Storage temperature range –20° C to +70° C
Rel. humidity (meets DIN EN 60068-2-3, non-condensing) 95% at +40° C
Mechanical resistance, Sinusoidal vibration (meets DIN EN 60068-2-6, DIN EN 61010-1 and MIL-T-28800D class 5) 5 Hz to 150 Hz, max. 2 g at 55 Hz, 55 Hz to 150 Hz: 0.5 g constant
Mechanical resistance, Random vibration (meets DIN EN 60068-2-64) 10 Hz to 500 Hz: 1.9 g
Mechanical resistance, Shock (meets DIN EN 60068-2-27 and MIL-STD-810) shock spectrum
Electromagnetic compatibility meets EN 555011 class B and EN 61326 (EMC Directive 89/336/EEC)
EMI field strength 10 V/m
Safety class DIN EN 61010-1 / IEC61010-1 UL3111-1; CSA22.2 No:1010.1
Dimensions (W x H x D) 219 mm x 147 mm x 350 mm
Weight approx. 7.4 kg
Power supply, Input voltage range 100 V to 240 V (AC), 50 Hz to 60 Hz, autoranging
Power supply, Power consumption <35 VA
Important: Maximum input level: +33 dBm (50 MHz to 3 GHz), +26 dBm (10 MHz to 50 MHz), +20 dBm (9 kHz to 10 MHz). Maximum DC voltage: 30 V.
Important: Important: As a highly innovative company, we continuously refine our products. Please check the manufacturer homepage (www.fs300.rohde-schwarz.com) for new applications and features.
Recommended pairing: add the R&S FS300-K1 PC software for USB-based remote control and test-report generation, or the R&S ZZA-300 rack adapter for 19-inch rack installation.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Rohde

Condition

Pre-Owned

Manufacturer

Rohde & Schwarz

Spec_ana_freq