Skip to product information
1 of 1
Used

N9030A Agilent Signal Analyzer Used

N9030A Agilent Signal Analyzer Used

Shipping calculated at checkout.
Calibrations
check availability
Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Features:

Functionality

  • 3 Hz to 3.6, 8.4, 13.6, 26.5, 43, 44, or 50 GHz; internal preamplifier options up to 50 GHz
  • 10 MHz (standard), 25, 40, or 140 MHz analysis bandwidth
  • Extend frequency to 325 GHz and beyond with external mixing
Share on
View full details

Performance

  • ±0.19 dB absolute amplitude accuracy
  • +22 dBm third order intercept (TOI)
  • -172 dBm displayed average noise level (DANL) with preamplifier and noise floor extension
  • -83 dB (-88 dB nominal) W-CDMA ACLR dynamic range (with noise correction on)

Measurement Applications & Software

  • PXA supports over 25 measurement applications, covering cellular communication, wireless connectivity, digital video, and general purpose.
  • Advanced analysis of more than 70 signal formats; software runs inside the PXA.
  • MATLAB data analysis software for general purpose data analysis, visualization, and measurement automation.
  • Agilent's PowerSuite one-button power measurements included as standard

Automation & Communication Interface

  • LXI class C compliant, SCPI and IVI-COM
  • USB 2.0, 1000Base-T LAN, GPIB
  • Programming remote language compatibility with PSA, 8566/68, 856x, and more
  • Common X-Series user interface/Open Windows® XP operating system

The PXA signal analyzer is the highest-performance member of the X-Series and is the evolutionary replacement for your current performance signal analyzer. It provides frequency coverage up to 50 GHz and ensures present and future flexibility through optional measurement capabilities and hardware expandability. Through external mixing with Agilent or third-party harmonic mixers, the PXA can measure signals to 325 GHz and beyond. The PXA’s advanced performance, flexibility, capability, and expandability enable you to address demanding applications in aerospace, defense, commercial communications and more. In addition, the PXA includes extensive remote language compatibility features that make it easier to replace existing Agilent performance spectrum analyzers.

With the performance and flexibility of the PXA, you’ll be equipped to create state-of-the-art original designs. Unravel complex signals through the PXA’s broad set of measurement applications and demodulation capabilities, such as the Keysight 89600 VSA software and MATLAB. Adding real-time spectrum analyzer capabilities is an upgradable option for new and existing PXAs, enabling you to see, capture and understand fleeting, close-in signals at very low levels.

The PXA is ideally suited for high-performance R&D applications in aerospace & defense and commercial wireless communications. The PXA analyzes signals over wider bandwidths, reduces measurement uncertainty and reveals previously hidden signals with Noise Floor Extension.

NFE technology provides a dramatic improvement in the PXA’s ability to accurately measure low-level signals approaching the theoretical “kTB” noise floor. NFE reduces the measurement noise by up to 10 dB and more. With increased averaging, the PXA’s effective noise floor can be extended by up to 10 dB because 90% or more of the contributed noise power is predictable, which means it can be measured, calibrated and then eliminated during normal measurements.

Even at the extremes of signal analysis, your high-performance analyzer should be ready for anything. That’s why we offer real-time spectrum analysis as an upgradable option for new and existing PXAs. With real-time spectrum analyzer capabilities, the PXA offers the widest analysis bandwidth and dynamic range to ensure maximum probability of intercept (POI). And for even deeper analysis and thorough characterization of complex signals, a real-time PXA can also be equipped with the Keysight 89600 VSA software. See, capture and understand the most elusive signals—known or unknown.

  • Detect signals with 100% POI with durations as short as 3.57 µs
  • Scan wide spans of spectrum with 160 MHz real-time bandwidth up to 50 GHz frequency range
  • See small signals in the presence of large ones with up to 75 dB of spurious-free dynamic range 

Every PXA also includes I/Q analyzer functionality and Keysight PowerSuite. It allows viewing of magnitude, phase, or I/Q behavior for complex modulated signals over the maximum available analysis bandwidth. PowerSuite provides a wealth of one-button, standards-based power measurements such as TOI, harmonic distortion and burst power.

Model No

N9030A

Condition

Used

Manufacturer

Agilent

Frequency

50 GHz

205

Basic VSA-lite

235

Pre-amplifier

333

X-Series analyzer connectivity

3FP

Amplitude correction and limit lines

4FP

TOI and harmonics

503

9 kHz to 3.0 GHz Frequency Range

507

Frequency range , 9 kHz to 7.0 GHz

513

Frequency range , 10 Hz to 13.6 GHz

526

20 Hz to 26.5 GHz

550

Frequency range , 3 Hz to 50 GHz

5FP

ACP 18 Carrier

6FP

TV Trigger and IQ Analyzer

AYA

Vector modulation analysis

B1X

Increase analysis bandwidth from 10/25 to 160 MHz

B25

25MHz Maximum bandwidth

B40

40MHz Maximum bandwidth

BBA

Baseband Analog I/Q

CRP

Arbitrary IF output

DP2

Digital processor with 2 GB capture memory

EA3

Electronic attenuator (Frequency range 20 Hz to 3.6 GHz)

EDP

Enhanced display package

EMC

Basic precompliance EMI features

EP1

Enhanced Phase Noise Performance

EP3

Enhanced phase noise

EP4

Enhanced phase noise performance , CXA

ESC

External source control

FS1

Fast sweep capability

FSA

Mechanical attenuator , 2 dB steps , 0 to 70 dB

LFE

Low Frequency Enabled (allows frequency range to 3 Hz)

LNP

Low noise path

LOT 772664

550 , DP2 , EA3 , EP1 , FS1 , FSA , LFE , LNP , MPB , NFE , NUL , P50 , DFR , RTL N9060A2-7FP , N9068A AFP AND CFP , N9069A AFP

LOT 793953

508 , B25 , B40 , BBA , DP2 , EP2 , FS1 , MPB , NF2 , P08 , PFR , RTL. N9060A 3 to 7 FP. N9060B 2FP. N9064A AFP. N9068A CFP. N9071A CFP. N9073A A to E FP. N9077A BFP. N9079A CFP. N9080B BFP. N9082B AFP

MPB

Microwave preselector bypass

N6060A 2FP

Spectrum Analyzer Measurement Application

N9020A-B25

Analysis bandwidth , 25 MHz

N9060A 2 TO 7 FP

2FP Spectrum Analyzer Measurement , 3FP Amplitude Correction and Limit Lines , 4FP TOI and Harmonics , 5FP ACP 18 Carrier , 6FP TV Trigger and IQ Analyzer Enhancement , 7FP Zero Span , Register , Trace , and Spurious Enhancements

N9060A-2FP

Spectrum Analyzer Measurement Application

N9060A-3FP

Amplitude correction and Limit Lines

N9060A-4FP

TOI and Harmonics

N9060A2-4FP

TOI and Harmonics

N9060A2FP

Spectrum Analyzer Measurement Application

N9060B2FP

Spectrum Analyzer Measurement Application

N9060B2FR

Spectrum Analyzer Measurement Application

N9068A AFP

Phase Noise Feature Enhancements

N9069A AFP

Phase Noise Feature Enhancements

N9073A-1FP

Standard-based , one-button W-CDMA measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)

N9073A-2FP

Adds HSPA measurements; requires 1FP/1TP

N9075A-2FP

Standard-based , one-button Mobile WiMAX measurements; supports analog baseband analysis with Option BBA (BBIQ inputs)

NFE

Noise Floor Extension

NUL

LO/IM nulling , Minimizes the LO feed-thru and intermodulation distortion

P03

Preamplifier , 100 kHz to 3.6 GHz

P08

8.4 GHz Preamplifier

P50

Preamplifier , 50 GHz

PC4

Upgrade to dual core processor with removable solid state drive

PC5

Single core 64-bit performance processor , 4GB RAM , removable SSD

PFR

Precision frequency reference 10 MHz

PLUS

Includes: N9060A 3 TO 7FP , N9068A 2FP , N9069A 1 AND 2FP , N9071A 2 AND 3FP , N9072A 2FP AND 2TP , N9073A 1FP , 1TP , 2 AND 3 FP , A TO DFP , N9075A 2FP , N9076A 1FP , N9077A 2FP , N9079A 1 AND 2FP , N9080A 1FP , N9082A 1FP

PRC

Portable configuration

RTL

Real-time link

T03

9 kHz to 3 GHz Tracking Generator Frequency

UK6

Commercial calibration test data

YAS

Y-axis screen video output