Key Features At A Glance

  • Frequency Domain Reflectometry (FDR) for accurate return loss, SWR, and Distance-To-Fault measurements on transmission lines and antennas
  • Site Master family covers 5 MHz to 20 GHz across models, with handheld portability and battery operation for field use
  • Built-in Distance-To-Fault on all models pinpoints location and reflection amplitude of transmission line faults
  • High dynamic range exceeding 90 dB on two-port models (S251A/S251B) enables accurate isolation, gain, and insertion loss measurement
  • High RF interference immunity allows measurements on active sites without loss of accuracy
  • Spectrum analysis capability on S114B (100 kHz to 1.2 GHz) and S332B (100 kHz to 3.0 GHz) for signal mapping and interference identification
  • Vector error correction on S800 series microwave models for improved measurement quality versus traditional scalar techniques
  • RS-232 interface and Site Master Software Tools support data download, historical trace comparison, and database storage on Windows PCs
Share on
View full details

The Anritsu S332B Site Master is a handheld transmission line and antenna analyzer with integrated spectrum analysis capability, designed for field installation, deployment, and periodic maintenance of cellular, PCS/DCS, paging, WLAN/WPBX, and other wireless communication systems. The S332B covers 25 MHz to 3300 MHz for cable and antenna measurements and adds spectrum analysis from 100 kHz to 3.0 GHz, combining two field measurement functions in a single battery-operated instrument.

Site Master is used widely in installation, deployment, and periodic maintenance of cellular communication sites. Field engineers and technicians use it to identify, record, and solve problems including coverage, interference, antenna alignment, in-band interference from unwanted sources, and other path-related signal problems. The S114B and S332B models specifically address site surveys, signal mapping, and antenna placement optimization in WLAN and WPBX network installations.

Brand Heritage

Anritsu acquired Wiltron Company in 1990, consolidating Wiltron's RF and microwave measurement expertise into the Anritsu organization. Site Master and many of Anritsu's other handheld RF instruments draw on the engineering heritage of both companies.

Compare Other Models in This Series

The Site Master family is a line of handheld cable, antenna, and spectrum analyzers from Anritsu covering frequencies from 5 MHz to 20 GHz across multiple models. All models share Anritsu's Frequency Domain Reflectometry approach, built-in Distance-To-Fault analysis, battery operation for field use, and the menu-driven interface that simplifies site-to-site deployment and maintenance.

Within the family, models differ by frequency coverage, addition of spectrum analysis capability, addition of a second test port for transmission measurements (gain and insertion loss), and extension into microwave frequencies with waveguide and vector error correction support. The A and B series suffixes generally indicate generational updates, with B series instruments offering expanded data storage and additional measurement features.

Each model linked below is its own product page with pre-owned-matched pricing. Site Master instruments listed as Pre-Owned have been through ValueTronics inspection and performance verification; Factory New units carry the manufacturer warranty. Use the comparison table to narrow by frequency range, spectrum analysis capability, two-port configuration, and data storage capacity, then click through to the specific model that fits the application.

The S332B specifically combines cable and antenna analysis from 25 to 3300 MHz with spectrum analysis from 100 kHz to 3.0 GHz in a single instrument, making it the choice when both transmission line maintenance and on-site RF spectrum measurement are needed in the same field visit. Data storage supports up to 200 memory locations with alpha-numeric labeling and time/date stamping.

Frequency range divides the family into three groups: lower-frequency models S113B and S114B (5 to 1200 MHz), mid-range cellular and PCS models S251A/S251B (625 to 2500 MHz), broadband models S331A/S331B/S332B (25 to 3300 MHz) and S400A (25 to 4000 MHz), and microwave models S810A (3.3 to 10.5 GHz), S818A (3.3 to 18 GHz), and S820A (3.3 to 20 GHz). Within each frequency tier, instruments differ by sweep speed, resolution, data storage capacity, and presence of spectrum analysis or two-port transmission measurement capability.

The S114B and S332B add spectrum analysis covering 0.1 to 1200 MHz and 0.1 to 3000 MHz respectively. The S251A and S251B add a second test port supporting gain and insertion loss measurement from 625 to 2500 MHz. The S800 series microwave instruments add vector error correction and waveguide calibration support. See the comparison table for the full specification breakdown by model.

Model Frequency Range Built-in Features Memory Locations
S332B 25-3300 MHz DTF, Spectrum Analysis 200
S113B 5-1200 MHz DTF 200
S114B 5-1200 MHz DTF, Spectrum Analysis 200
S251A 625-2500 MHz DTF, Two-port (Gain/Insertion Loss) 50

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • User's Guide
  • Soft Carrying Case
  • AC-DC Adapter
  • Automotive Cigarette Lighter/12 Volt DC Adapter
  • One Year Warranty
  • CD ROM containing Fault Location (DTF), Smith Chart and Software Management Tools
  • Serial Interface Cable
  • Rechargeable Battery, NiMH

Product Core & Specifications

Specification Value
Return Loss
Range 0.00 to 54.00 dB
Resolution 0.01 dB
SWR
Range 1.00 to 65.00
Resolution 0.01
Distance-To-Fault
Vertical Range, Return Loss 0.00 to 54.00 dB
Vertical Range, SWR 1.00 to 65.00
Horizontal Range 0 to (# of data pts. x Resolution) to a maximum of 1000 m (3281 ft.), # of data pts. = 129, 256, 516
Gain/Insertion Loss
Range -120 to +100 dB
Resolution 0.1 dB
Wattmeter (RF Power Monitor) Option
Display Range -80.0 to +80.0 dB; 10.0 pW to 100.0 kW; 10.0 uW to 100.0 mW
Detector Range -50.0 to +20.0 dBm
Offset Range 0.0 to +60.0 dB
Resolution 0.1 dB; 0.1 x W
Transmission Line Loss (one-port)
Range 0.00 to 20.00 dB
Resolution 0.01 dB
Test Port Connector
Type Precision N female
Maximum Input Without Damage
N(f) Test Ports +20 dBm, 50 Ω, +50 Vdc
RF Power Detector +20 dBm, 50 Ω, +50 Vdc
Spectrum Analyzer (S114B, S332B only)
Frequency Range (S114B) 100 kHz to 1.2 GHz
Frequency Range (S332B) 100 kHz to 3.0 GHz
Frequency Reference Aging ±1 ppm/yr.
Frequency Reference Accuracy ±2 ppm
Frequency Span 0 Hz (zero span); 100 kHz to 1.2 GHz (S114B); 100 kHz to 3.0 GHz (S332B)
Sweep Time 0.5 sec.
Resolution Bandwidth (-3dB width) 10 kHz, 30 kHz, 100 kHz, 1 MHz
Video Bandwidth (Range -3dB) 3 kHz, 10 kHz, 30 kHz and 300 kHz
SSB Phase Noise (1 GHz) @ 30 kHz Offset ≤74 dBc/Hz
Spurious Responses, Input Related ≤-45 dBc
Spurious Residual Responses ≤-80 dBm
Amplitude
Measurement Range -90 dBm to +20 dBm
Dynamic Range ≥60 dB
Maximum Safe Input Level +20 dBm max. measurement safe input; +27 dBm max. input (damage); +27 dBm Peak Pulse Power; +50 Vdc
Displayed Average Noise Level ≤-90 dBm (400 kHz span)
Display Range 2 to 15 dB/div. In 1 dB steps. Ten divisions displayed.
RF Input VSWR 2.0:1
Amplitude Accuracy ±1.5 dB
Total Level Accuracy ±2 dB
General
RS-232 9 pin D-sub, three wire serial
Electromagnetic Compatibility Meets European Community Requirements for CE marking
Operating Temperature -0°C to 50°C
Storage Temperature -20°C to 75°C
Weight (A Series) 1.36 kgs. (3.0 lbs.)
Weight (B Series) 1.81 kgs. (4.0 lbs.)
Size (A Series) 20.3 x 17.8 x 5.72 cm (8 x 7 x 2.25 in.)
Size (B Series) 25.4 x 17.8 x 6.10 cm (10 x 7 x 2.4 in.)
Measurement Accuracy
Return Loss and SWR Accuracy < ± 0.9 dB, < ± 0.03 SWR typical worst case (assumes measurement of a 22 dB return loss device with precision calibration components after 5 minute warm up)
Directivity (Precision 7/16 Components) ≥45 dB
Directivity (N Components SM/PL, SM/PNFL, 4.0 GHz) ≥42 dB
Directivity (N Components 28N50A, 18.0 GHz) ≥40 dB
Precision Waveguide Load ≥45 dB (frequency range dependent)
Cable Loss Accuracy ≤±1.0 dB typical, after calibration for insertion losses of <4.0 dB. Assumes cable return loss >26 dB.
Cable Loss Repeatability ≤± 0.05 dB, typical
Important: Maximum RF Input VSWR: 2.0:1. Maximum Input Without Damage on N(f) Test Ports and RF Power Detector: +20 dBm, 50 Ohm, +50 Vdc. RF Power Detector additionally rated for +27 dBm maximum input and +27 dBm Peak Pulse Power.Important: All specifications apply when calibrated at ambient temperature after a five minute warm up.Important: Operation at temperatures to -10.0°C is normal. However, please note that the LCD display will fade at low temperature extremes.Important: The RF Wattmeter Power Monitor (Option 5) is optional and the RF Detector is not included; select an appropriate RF Detector (e.g., 5400-71N50, 560-7N50B, 560-7K50, or 560-7VA50) separately for Wattmeter operation.Important: Precision calibration components (Open, Short, Load) used for vector error correction are not included with the base instrument and must be ordered separately from the Optional Accessories or Universal Waveguide Component Accessories sections to enable accurate measurements.Recommended pairing: Site Master Software Tools (included on CD-ROM) for Windows-based trace analysis, Smith Chart display, and historical performance comparison. For RF power monitoring, add Option 5 RF Wattmeter Power Monitor with a compatible RF detector (560-7N50B for 10 MHz to 20 GHz coverage, or 5400-71N50 for the standard 1 to 3000 MHz range).

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Anritsu

Condition

Used

Manufacturer

Anritsu

Frequency

Frequency