Key Features At A Glance

  • Frequency coverage from 10 MHz to 43.5 GHz (N5244A) or 10 MHz to 50 GHz (N5245A) for broad RF and microwave component characterization
  • Available as 2-port (Option 200/219/224) or 4-port (Option 400/419/423) configurations to match single-ended or balanced/differential device test needs
  • Optional internal second source, combiner, and mechanical switches (Option 224/423) support multi-stimulus measurements such as intermodulation and gain compression
  • Optional high-accuracy noise figure hardware and firmware (Option 029) with dedicated noise receivers covering 10 MHz to 6 GHz and 6 GHz to 50 GHz
  • Extended power range, source/receiver attenuators, and bias-tees available via Option 219/419 for active-device test and DC-biased measurements
  • Direct receiver access loops (six on 2-port, twelve on 4-port) enable extended dynamic range and external signal conditioning
  • 1 Hz frequency resolution with ±1 ppm frequency accuracy and selectable IF bandwidths from 1 Hz to 15 MHz (nominal)
  • Pulse measurement capability with optional pulse generators (Option 025) and pulse modulators (Options 021/022) for point-in-pulse and pulse-profile testing
Share on
View full details

The Agilent PNA-X Network Analyzer family — comprising the N5244A (10 MHz to 43.5 GHz) and N5245A (10 MHz to 50 GHz) — is a high-performance vector network analyzer platform configurable as either a 2-port or 4-port instrument. Both models share a common architecture and are differentiated primarily by upper frequency limit, with option packages that add extended power range, internal second sources, combiners, mechanical switching, bias-tees, pulse capability, and dedicated noise figure hardware.

Per the datasheet, the PNA-X is applied to RF and microwave component characterization tasks including S-parameter measurement, noise figure measurement (with Option 029), pulse measurements (point-in-pulse and pulse-profile with Options 021/022/025), and measurements that require multiple internal sources such as intermodulation and gain compression (with Options 224 or 423). The 4-port configurations support balanced and differential device measurements, and the front-panel access loops on all options allow external signal conditioning between the internal couplers and receivers.

ValueTronics maintains its inventory of vector network analyzers — including the PNA-X family — at our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Unlike pass-through brokers, every {{CONDITION}} PNA-X passing through our facility is handled, documented, and shipped from the same location where our technical resources reside, giving buyers a single point of accountability from quote through delivery.

Brand Heritage

The N5244A and N5245A were introduced under the Agilent Technologies brand. Agilent's electronic measurement business was transferred to Keysight Technologies in 2014, so instruments originally branded Agilent in this product family are part of the Hewlett-Packard → Agilent → Keysight test and measurement lineage. Calibration service and parts continuity for these instruments flow through that successor relationship.

Compare Other Models in This Series

The PNA-X family covered by this datasheet consists of two base models — the N5244A and the N5245A — distinguished only by upper frequency limit. The N5244A covers 10 MHz to 43.5 GHz; the N5245A extends to 50 GHz. Both models share the same architecture, the same option structure, and the same corrected and uncorrected performance specifications within their common frequency range.

Each base model is offered in 2-port (Option 200) or 4-port (Option 400) configurations, with additional option packages that add extended power range and bias-tees (Option 219 / 419), an internal second source and combiner with mechanical switches (Option 224 / 423), and dedicated noise figure hardware (Option 029). The right configuration for a given lab depends on the maximum frequency required, the number of test ports, and whether features such as multi-source measurements, noise figure, or pulse capability are part of the planned measurement set.

Each pre-owned N5244A or N5245A configuration listed below is its own dedicated product page with condition-matched pricing. Confirm the model number and the full option string when selecting, since the option content drives the available measurement capability.

Per the datasheet, the N5244A and N5245A differ in upper frequency limit only — 43.5 GHz versus 50 GHz. Specifications above 43.5 GHz (the 43.5 GHz to 47 GHz and 47 GHz to 50 GHz bands documented in the system dynamic range, maximum leveled power, and noise floor tables) apply only to the N5245A.

The 2-port options (200 / 219 / 224) and 4-port options (400 / 419 / 423) add capability incrementally: the base 200/400 options provide the standard test set; 219/419 add extended power range, source and receiver attenuators, and bias-tees; and 224/423 add an internal second source (224 only), an internal combiner, and mechanical switches. Option 029, which adds noise figure hardware, requires Option 224 or 423. The comparison table that follows summarizes which configurations carry which capability.

Model Frequency Range Ports Test Port Connector
N5244A 10 MHz to 43.5 GHz 2 or 4 2.4 mm (male)
N5245A 10 MHz to 50.0 GHz 2 or 4 2.4 mm (male)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Description Specification / Typical
Frequency Information, All Options
N5244A Frequency Range 10 MHz to 43.5 GHz
N5245A Frequency Range 10 MHz to 50.0 GHz
Frequency Resolution 1 Hz
Frequency Accuracy ±1 ppm
Frequency Stability ±0.05 ppm, -10 °C to 70 °C (typ); ±0.1 ppm/yr maximum (typ)
Power
Power Resolution 0.01 dB
Maximum Settable Power (typical) 30 dBm
Minimum Settable Power (typical) -30 dBm (Opt 200/400); -90 dBm (Opt 219/419/224/423)
Reference Level
Range ±500 dB, ±500°
Resolution 0.001 dB, 0.01°
Damage Input Level
Test Ports 1, 2, 3, 4 RF: > +30 dBm; DC: 40 V
Source 2 Out 1, Source 2 Out 2 (Option 224 only) RF: > +30 dBm; DC: 0 V
Test Port 1, Noise Mode (Option 029 only) RF: > +10 dBm; DC: 40 V
Test Port 2, Noise Mode (Option 029 only) RF: > +27 dBm; DC: 40 V
Miscellaneous
System IF Bandwidth Range 1 Hz to 15 MHz, nominal (7/10/15 MHz IFBWs require FW A.09.42+ and DSP version 5)
CPU Intel 2.0 GHz Core i7 (some instruments may have a different CPU)
LXI Class C
Front Panel
Test Port Connector 2.4 mm (male), 50 ohm (nominal)
Jumpers 2.4 mm (female) connectors with 2.4 mm (male) jumper cables
USB 2.0 Ports 4 Type-A female (front)
Display 26.3 cm (10.4 in) diagonal color active matrix LCD; 1024 x 768 resolution
Rear Panel
10 MHz Reference In BNC female; 10 MHz ±10 ppm; -15 dBm to +20 dBm; 200 Ω nom
10 MHz Reference Out BNC female; 10 MHz ±1 ppm; +10 dBm ±4 dB into 50 Ω; harmonics <-40 dBc typ
External IF Inputs SMA female; A, B, C, D, R (4-port); A, B, R1, R2 (2-port); 50 Ω
External IF RF Damage Level +23 dBm
External IF DC Damage Level 5.5 VDC
Bias Tee Inputs BNC(f) for ports 1, 2, 3 and 4; Fuse 500 mA bi-pin; Max bias current ±200 mA; Max bias voltage ±40 VDC
Trigger Inputs/Outputs BNC(f), TTL/CMOS compatible
Test Set IO 25-pin D-Sub
Handler IO 36-pin parallel I/O
GPIB Two ports (controller and talker/listener), 24-pin D-Sub, IEEE-488 compatible
LAN 10/100BaseT Ethernet, 8-pin, auto-select
USB Ports (rear) Five (4 Host + 1 Device), USB 2.0 compatible
VGA Video Output 15-pin mini D-Sub
Line Power
Frequency, Voltage 50/60/400 Hz for 100 to 120 VAC; 50/60 Hz for 220 to 240 VAC (auto switching)
Max Power 450 watts
Dimensions
Height (with bottom feet) 279.1 mm (11.0 in)
Width (with handles and rack-mount flanges) 482.9 mm (19.0 in)
Depth (with front and rear panel hardware, handles) 649.6 mm (25.6 in)
Weight, 2-port (Option 224 with 029) 46.3 kg (102 lb) net
Weight, 4-port (Option 423 with 029) 49.0 kg (108 lb) net
Important: Maximum test port damage input level: greater than +30 dBm RF and 40 VDC for test ports 1, 2, 3, 4. With Option 029 in Noise Mode, the test port 1 damage input level is reduced to greater than +10 dBm RF.Important: The Corrected System Performance with Cal Kits and Dynamic Accuracy Charts apply ONLY to N5244A/45A models with serial numbers starting with MY5244/45, SG5244/45, and US5244/45, and above.Important: All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on.Important: Specifications for the N5244AS and N5245AS Option H85, when configured in standard configuration, are the same as those of closest N5244A and N5245A option configuration.Important: Direct receiver access should only be used when the receiver input will never exceed its maximum receiver input. The extended range is only available in one-path transmission measurements.Important: System dynamic range may typically be degraded at particular frequencies below 500 MHz due to spurious receiver residuals.Important: A calibration kit (such as the 85056A 2.4 mm mechanical cal kit or N4693A 2-Port ECal module) and flexible test port cable set (such as the 85133F) are required to achieve the Corrected System Performance specifications and must be ordered separately if not already owned.Recommended pairing: the 85056A 2.4 mm mechanical calibration kit or the N4693A 2-port Electronic Calibration Module, both of which are the specific calibration standards used to define the PNA-X's corrected system performance in this datasheet.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Frequency