The HVD3000A series is a family of high voltage differential probes engineered to deliver high common-mode rejection ratio (CMRR) over a broad frequency range, simplifying the measurement challenges found in noisy, high common-mode power electronics environments. The probe design is easy to use and enables safe, precise high voltage floating measurements.
The series is built to cover the fullest range of power-electronics measurement tasks: 120 V and 240 V switch-mode power supplies and half-bridge circuit topologies, 600 V-class three-phase electrical apparatus, 5 kV-class electrical apparatus, single-phase and three-phase solar PV inverters including newer 1500 Vdc string inverters per IEC/EN 61010-031:2015, high-power DC-DC converters operating at 500 Vdc or higher, and upper-side MOSFET/IGBT gate-drive measurements. Multiple probes can be used together to understand complex device switching performance.
ValueTronics stocks and holds its own test-and-measurement inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Holding inventory directly lets us confirm condition and move quickly on orders.
LeCroy Corporation, founded in 1964, was acquired by Teledyne Technologies in 2012 and has since operated as Teledyne LeCroy. The probes in this series carry the Teledyne LeCroy brand.
The HVD3000A series brings together high voltage differential probes that share a common design — high CMRR over a broad frequency range, 1% gain accuracy, high offset capability, AutoZero, and the ProBus active probe interface — while differing in safety rating, bandwidth, and differential voltage range. The family is organized to cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V-class and 5 kV-class electrical apparatus.
Within the family, the HVD310xA models serve 1 kV-rated 600 V-class measurements, the HVD3206A and HVD3220 add a 2 kV safety rating with 1500 Vdc CAT III solar PV capability, and the HVD3605A extends coverage to 5 kV-class apparatus at a 6 kV rating. Each model is specified to provide the best available gain accuracy, widest differential and offset voltage range, and strong CMRR within its rating class.
Each new model in the series listed below is its own dedicated product page with condition-matched pricing. Select the specific model and safety rating that matches your application to see its current new availability and price.
The models differ primarily in three dimensions shown in the comparison table that follows: safety rating (1 kV for the HVD310xA models, 2 kV for the HVD3206A and HVD3220, and 6 kV for the HVD3605A), bandwidth (from 25 MHz on the HVD3102A up to 400 MHz on the HVD3220), and differential voltage range at high attenuation (from 1500 V on the HVD3102A/HVD3106A up to 7000 V DC + peak AC on the HVD3605A).
Cable length is a further differentiator: standard models ship with a 2 meter cable, while the -6M variants (HVD3106A-6M, HVD3206A-6M) and the HVD3605A use a 6 meter cable. The HVD3220 offers four switchable attenuation ratios (50x/100x/250x/500x) and the tightest guaranteed gain accuracy in the family at 0.35%–0.7%. Consult the comparison table for the exact bandwidth, rise time, voltage range, and attenuation of each model.
| Model | Safety Rating | Bandwidth | Max Differential Range |
|---|---|---|---|
| HVD3206A | 2 kV | 120 MHz | 2000 V |
| HVD3102A | 1 kV | 25 MHz | 1500 V |
| HVD3106A | 1 kV | 120 MHz | 1500 V |
| HVD3106A-6M | 1 kV | 80 MHz | 1500 V |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Bandwidth | 120 MHz |
| Rise Time (10-90) | 2.9 ns |
| Differential Voltage Range (High Attenuation) | 2000 V (DC + peak AC) from 7 to 500 V/div with up to 1500V offset. |
| Differential Voltage Range (Low Attenuation) | 27.6 V (DC + peak AC) from 100 mV/div to 6.9 V/div with up to 150V offset. |
| Common Mode Voltage Range | ±2000 V (DC + peak AC) |
| Maximum Input Voltage to Earth | ±2000 Vpk (nominal, either input to ground) |
| Max Safe Input Voltage | 2000 V (DC + peak AC) CAT I *; 1500 Vdc CAT III; 1000 Vrms CAT III |
| Sensitivity | 100 mV/div to 6.9V/div (50X); 7V/div to 500V/div (500X) |
| Gain Accuracy | 1% (LF, guaranteed) |
| Slew Rate | 400 V/ns (maximum) |
| Attenuation | 50x / 500x |
| Input Impedance | 10 MΩ || 2.5 pF (between inputs); 5 MΩ || 5.0 pF (either input to ground) |
| Input Coupling | DC only |
| Output Coupling | AC or DC coupling |
| Output Termination | 1 MΩ |
| Interface | ProBus |
| Input Lead Length | 40 cm |
| Cable Length (input lead to oscilloscope connection) | 2.25 m |
| Noise and Rejection | |
| CMRR (Typical) | DC - 60 Hz: 85 dB; 1 MHz: 65 dB; 5 MHz: 40 dB; 20 MHz: 30 dB; 100 MHz: 30 dB |
| Noise (Probe) | 50X: <30 mVrms; 500X: <150 mVrms (referred to input) |
| Environmental | |
| Temperature (Operating) | 0°C to 50°C |
| Temperature (Non-Operating) | -40°C to 70°C |
| Humidity (Operating) | 5% to 80% RH (Non-Condensing) up to 30°C, decreasing linearly to 45% RH at 50°C |
| Humidity (Non-Operating) | 5% to 95% RH (Non-Condensing), 75% RH above 30°C, 45% RH above 40°C |
| Altitude (Operating) | 3000 m maximum. When used with clip accessories, 2000 m maximum |
| Altitude (Non-Operating) | 10,000 m |
| Pollution Degree | 2, Indoor use only |
| Certifications | |
| CE | LVD Directive 2006/95/EC; EMC Directive 2004/108/EC; IEC/EN 61010-031:2015; IEC/EN 61326-1:2013 |
| UL Listed | UL 61010-031 (Second Edition) |
| cUL Listed | CAN/CSA-C22.2 No. 61010-031-15 |
Important: CAT I ratings marked with an asterisk in the specifications are per IEC/EN 61010-031/A1:2008; no rated measurement category applies per IEC/EN 61010-031:2015.
Important: The HVD3220 and HVD3206A support 1500 Vdc solar photovoltaic (PV) measurements per the IEC/EN 61010-031:2015 standard, with a 1500 Vdc CAT III and a 2000 V (DC + peak AC) CAT I rating.
Important: "No Accessory (NOACC)" probe versions (HVD3102A-NOACC, HVD3106A-NOACC) ship without tip accessories; use your existing accessories or purchase just the ones you want.
Important: The ProBus interface provides power and communication to the probe, eliminating the need for a separate power supply or batteries; attenuation is automatically selected based on the oscilloscope gain range (V/div) setting.
Important: Operating altitude is 3000 m maximum, reduced to 2000 m maximum when used with clip accessories.
Recommended pairing: the PK-HV-001 High Voltage Replacement Accessories Kit supplies replacement 4 mm tip adapters, safety alligator clips, and plunger clips (two each) for these probes.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Teledyne
Condition
Factory New
Manufacturer
Teledyne LeCroy
Volt_prob_freq
120 MHz
Volt_prob_volts
2000 V
Request A Quote