Key Features At A Glance

  • Bandwidth options from 100 MHz to 1 GHz across the series, available in 2-channel or 4-channel configurations
  • Sample rates of 2 GSa/s (100/300 MHz models) and 4 GSa/s (500 MHz/1 GHz models per channel; half-channel rates apply on top-tier models)
  • MegaZoom III deep memory architecture with 2 Mpts standard, 8 Mpts optional
  • Optional 16 digital channels (MSO variants) with mixed-signal triggering for time-correlated analog and digital debug
  • High-definition XGA (1024 x 768) display with 256 levels of intensity grading
  • Standard connectivity: USB host and device, 10/100 LAN, GPIB, XGA video output; LXI Class C compliant
  • Optional hardware-accelerated serial triggering and decode for I2C, SPI, USB, CAN, LIN, and FlexRay (separate license options)
  • Built-in help system in 11 languages and AutoProbe interface (300 MHz to 1 GHz models)
Share on
View full details

The Agilent 6000 Series Oscilloscope is a family of high-performance portable mixed-signal and digital storage oscilloscopes spanning 100 MHz to 1 GHz bandwidths, available in 2-channel and 4-channel configurations with optional 16 digital channels on MSO variants. Built around the third-generation MegaZoom III memory and display architecture, the 6000 Series combines responsive deep memory, fast waveform update rates, and a high-definition XGA display in a compact bench form factor.

The 6000 Series is positioned for engineers debugging mixed analog, digital, and serial designs. Application areas described for the family include general analog and digital circuit debug, embedded systems work using serial buses such as I2C and SPI, automotive serial bus debug on CAN, LIN, and FlexRay, USB protocol analysis, FPGA debug with Altera and Xilinx devices via dynamic probe options, and analog HDTV/EDTV video triggering on standards including 1080i, 1080p, 720p, and 480p as well as NTSC, SECAM, PAL, and PAL-M.

ValueTronics stocks and supports Agilent 6000 Series oscilloscopes from our 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where every {{CONDITION}} unit is handled by our own team rather than passed through a drop-ship channel. With more than three decades of test and measurement experience, we maintain inventory across the full 6000 Series range and provide direct, knowledgeable support for sellers integrating these scopes into existing benches, automated test racks, or service workflows.

Brand Heritage

Hewlett-Packard's test and measurement business was spun out as Agilent Technologies in 1999, and Agilent's electronic measurement business was subsequently transferred to Keysight Technologies in 2014. The 6000 Series was introduced under the Agilent brand and is part of the broader oscilloscope product lineage that continued under Keysight.

Compare Other Models in This Series

The Agilent 6000 Series is organized as a 16-model family spanning four bandwidth tiers (100 MHz, 300 MHz, 500 MHz, and 1 GHz) crossed with channel-count configurations (2-channel or 4-channel) and acquisition type (DSO for analog-only, MSO for analog plus 16 digital channels). Every model in the series shares the same MegaZoom III memory and display architecture, the same connectivity stack, and the same upgrade path — a DSO can be field-upgraded to an MSO via a logic cable kit and license, and standard 2 Mpts memory can be expanded to 8 Mpts.

Within the family, bandwidth tier drives both maximum sample rate and probe compatibility. The 100 MHz and 300 MHz models share a 2 GSa/s maximum sample rate and a different recommended passive probe (10074C included on 100 MHz models, 10073C on 300 MHz through 1 GHz models), while the 500 MHz and 1 GHz models share the 4 GSa/s sample rate and add full compatibility with the AutoProbe active probe ecosystem.

Each pre-owned 6000 Series model listed in the comparison table below is its own dedicated product page with condition-matched pricing and inventory. Use the comparison to identify the bandwidth tier, channel count, and acquisition type that match your application, then navigate to the specific model page for current availability.

The four bandwidth tiers within the 6000 Series — 100 MHz, 300 MHz, 500 MHz, and 1 GHz — determine the highest-frequency signal the instrument can accurately measure and set the maximum sample rate ceiling. The 100 MHz and 300 MHz tiers operate at 2 GSa/s, while the 500 MHz and 1 GHz tiers move to 4 GSa/s (with half-channel operation noted on the top tier). Peak-detect resolution also scales with tier, from 1 ns at 100 MHz down to 250 ps at 500 MHz and 1 GHz.

Within each bandwidth tier, the choice between 2-channel and 4-channel models, and between DSO and MSO variants, determines how many signals can be observed and triggered on simultaneously. MSO variants add 16 digital channels and mixed-signal trigger capability across the analog and digital domains, and the advanced serial decode options (CAN/LIN, FlexRay, and I2C/SPI in some configurations) are listed as available on 4-channel and 4+16 channel models. The comparison table below summarizes bandwidth, sample rate, memory, channel count, and digital channel availability across the family.

Model Bandwidth Max Sample Rate Scope Channels
DSO6034A 300 MHz 2 GSa/s 4
DSO6012A 100 MHz 2 GSa/s 2
MSO6012A 100 MHz 2 GSa/s 2
DSO6014A 100 MHz 2 GSa/s 4

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • User's guide (localized)
  • Service guide
  • Programmer's guide
  • Localized power cord
  • 10073C 10:1 divider passive probe with readout per scope channel
  • Front panel cover
  • Agilent I/O libraries suite 14.2
  • Standard 1-year warranty

Product Core & Specifications

Category Specification Value
Acquisition: Scope Channels Sample rate MSO/DSO601xA/603xA: 2 GSa/sec each channel; MSO/DSO605xA/610xA: 4 GSa/sec half channel, 2 GSa/sec each channel; Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off)
Acquisition: Scope Channels Memory depth (2 ch / 4 ch) Standard: 2 Mpts / 1 Mpts; Optional: 8 Mpts / 4 Mpts
Acquisition: Scope Channels Vertical resolution 8 bits
Acquisition: Scope Channels Peak detection MSO/DSO601xA: 1-ns; MSO/DSO603xA: 500-ps; MSO/DSO605xA/610xA: 250-ps
Acquisition: Scope Channels Averaging Selectable from 2, 4, 8, 16, 32, 64 ... to 65536
Acquisition: Scope Channels High resolution mode Average mode with avg = 1; 12 bits of resolution when ≥10 µs/div @ 4 GSa/s or ≥20-µs/div @ 2 GSa/s
Acquisition: Scope Channels Filter Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of scope, whichever is less) with vectors on and in real-time mode
Acquisition: Digital Channels (MSO only) Sample rate 2 GSa/sec one pod, 1 GSa/sec each pod
Acquisition: Digital Channels (MSO only) Maximum input frequency 250 MHz
Acquisition: Digital Channels (MSO only) Memory depth (scope channels off) One pod/both pods: Standard 2 Mpts/1 Mpts; Optional 8 Mpts/4 Mpts
Acquisition: Digital Channels (MSO only) Memory depth (scope channels on) One pod/both pods: Standard 625 Kpts/312 Kpts; Optional 2.5 Mpts/1.25 Mpts
Acquisition: Digital Channels (MSO only) Vertical resolution 1 bit
Acquisition: Digital Channels (MSO only) Glitch detection 2 ns (min pulse width)
Vertical: Scope Channels Bandwidth (-3dB) MSO/DSO601xA: DC to 100 MHz; MSO/DSO603xA: DC to 300 MHz; MSO/DSO605xA: DC to 500 MHz; MSO/DSO610xA: DC to 1 GHz
Vertical: Scope Channels AC coupled 3.5 Hz to model bandwidth
Vertical: Scope Channels Calculated rise time (=0.35/bandwidth) MSO/DSO601xA: 3.5 nsec; MSO/DSO603xA: 1.17 nsec; MSO/DSO605xA: 700 psec; MSO/DSO610xA: 350 psec
Vertical: Scope Channels Single-shot bandwidth MSO/DSO601xA: 100 MHz; MSO/DSO603xA: 300 MHz; MSO/DSO605xA: 500 MHz; MSO/DSO610xA: 1 GHz (in half-channel mode)
Vertical: Scope Channels Range MSO/DSO601xA: 1 mV/div to 5 V/div (1 MΩ); MSO/DSO603xA and MSO/DSO605xA: 2 mV/div to 5 V/div (1 MΩ or 50 Ω); MSO/DSO610xA: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
Vertical: Scope Channels Maximum input CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk; CAT II 100 Vrms, 400 Vpk; With 10073C or 10074C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk
Vertical: Scope Channels Offset range ±5 V on ranges <10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div; ±75 V on ranges >200 mV/div
Vertical: Scope Channels Dynamic range ±8 div
Vertical: Scope Channels Input impedance MSO/DSO601xA: 1 MΩ ±1% || 11 pF; MSO/DSO603xA/605xA/610xA: 1 MΩ ±1% || 14 pF or 50 Ω ±1.5%, selectable
Vertical: Scope Channels Coupling AC, DC
Vertical: Scope Channels BW limit MSO/DSO601xA: 20 MHz selectable; MSO/DSO603xA/605xA/610xA: 25 MHz selectable
Vertical: Scope Channels Channel-to-channel isolation DC to max bandwidth >40 dB
Vertical: Scope Channels ESD tolerance ±2 kV
Vertical: Scope Channels Noise peak-to-peak MSO/DSO601xA: 3% full scale or 2 mV; MSO/DSO603xA: 3% full scale or 3 mV; MSO/DSO605xA: 3% full scale or 3.6 mV; MSO/DSO610xA: 3% full scale or 4 mV (whichever is greater)
Vertical: Scope Channels DC vertical gain accuracy ±2.0% full scale
Vertical: Scope Channels DC vertical offset accuracy ≤200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; >200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
Vertical: Digital Channels (MSO only) Number of channels 16 logic timing channels - labeled D15 - D0
Vertical: Digital Channels (MSO only) Threshold groupings Pod 1: D7-D0; Pod 2: D15-D8
Vertical: Digital Channels (MSO only) Threshold selections TTL, CMOS, ECL and user-definable (selectable by pod)
Vertical: Digital Channels (MSO only) User-defined threshold range ±8.0 V in 10 mV increments
Vertical: Digital Channels (MSO only) Maximum input voltage ±40 V peak CAT I; transient overvoltage 800 Vpk
Vertical: Digital Channels (MSO only) Threshold accuracy ±(100 mV + 3% of threshold setting)
Vertical: Digital Channels (MSO only) Input dynamic range ±10 V about threshold
Vertical: Digital Channels (MSO only) Minimum input voltage swing 500 mV peak-to-peak
Vertical: Digital Channels (MSO only) Input capacitance ~8 pF
Vertical: Digital Channels (MSO only) Input resistance 100 kΩ ±2% at probe tip
Important: On 500 MHz and 1 GHz models (MSO/DSO605xA and MSO/DSO610xA), the 4 GSa/s maximum sample rate is a half-channel specification — achieved when only one of channels 1 or 2 and one of channels 3 or 4 are active. With all channels enabled in their tier, sample rate is 2 GSa/s per channel. Verify per-channel sample rate against your application's signal bandwidth before configuration.Important: Standard memory depth is 2 Mpts; 8 Mpts is optional (factory Option 8ML/8MH or user-installed N2911A/N2913A upgrade).Important: MSO functionality (16 digital channels) is available on MSO models or as a user-installed DSO-to-MSO upgrade kit (N2914A or N2915A); DSO base units do not include the 16-channel flying-lead logic probe.Important: Advanced serial triggering and decode options (N5424A CAN/LIN, N5423A I2C/SPI, N5432A FlexRay) are available on 4-channel and 4+16-channel models only.Important: AutoProbe interface and 50 Ohm input selection are available on 300 MHz to 1 GHz models only; 100 MHz models (601xA) use auto probe sense without the AutoProbe interface.Important: Some active probes require an external power supply (e.g., 1142A or N2773A/N2779A) sold separately; verify probe-supply compatibility before ordering.Important: FlexRay solution combines an Agilent 6000 Series MSO with a DECOMSYS::BUSDOCTOR 2 protocol analyzer, which is required separately.Recommended pairing: for analog work above 500 MHz on the 500 MHz and 1 GHz models, the AutoProbe interface supports Agilent active probes including the 1156A 1.5 GHz single-ended active probe and the 1130A 1.5 GHz InfiniiMax differential active probe system, both listed as recommended in the 6000 Series probe compatibility table.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Channels

4

Frequency

300 MHz

Record length

2 MPts

Sampling rate

2 GS/s

1

Oscilloscope-locked license

8ML

8 Mpts memory upgrade