Features:

  • Delayed Sweep
  • Time Base Auto Range
  • 10 Front Panel Setting Memories
  • Cursor Readout with 7 Measurements
  • 100MHz Bandwidth
  • Dual Channel
  • TV Synchronisation
  • Z-Axis Modulation Input
  • 100MHz Cursor Readout Analog Oscilloscope
View full details

The GOS-6100 Series is a 100MHz, two-channel, dual-sweep, and portable oscilloscope for general purpose use. A microprocessor-based operating system controls most of the functions of the instrument, including cursor readout and digitized panel setting.

On-screen alphanumeric readout and cursor function for voltage, time, frequency and phase measurement provide extraordinary operational convenience. The advance Time Base Auto-rang function conveniently acquires waveforms at the push of button (GOS-6103/ 6103C). Ten different user defined instrument settings (GOS-6103/ 6103C) can be saved and recalled without restriction.

The vertical deflection system has two input channels. Each channel has 11 basic deflection factors from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps from 0.5s to 50ns per division (delayed sweep, 50ms to 50ns per division). The trigger system provides stable triggering over the full bandwidth of the vertical deflection system.

Other Features:

  1. High intensity and internal graticule CRT - The oscilloscope employs a high intensity 6-inch retangular type cathode-ray tube with red internal graticule. It displays clear readable traces even at high sweep speeds. Internal graticule lines eliminate parallax-viewing error between the trace and the graticule line
  2. Temperature compensation - The oscilloscope uses a temperature compensation circuit to reduce the drift of base line and DC balance.
  3. 20MHz bandwidth limit - When it is hard to observe or trigger a signal because a high-frequency component is superimposed on the signal, use the 20MHz BWL function to reduce the bandwidth of the vertical deflection system and trigger system to 20MHz.
  4. Z-axis intensity modulation - For applying a blanking signal from an external source. The trace displayed on the screen may be intensity-modulated where pulse signal or time-scale marks are required.
  5. Trigger signal output - The signal selected by the TRIGGER SOURCE is available. This output may be used to connect to a frequency counter or other instrument.
  6. SMD manufacturing technology - The instrument is built by using the most advanced SMD technology so as to reduce the number of internal wiring and shorten the foil route on the pc board. This will also greatly increase the high frequency performance and the reliability of the product.

Model No

GOS-6103C