E5072A Agilent Network Analyzer Used

E5072A Agilent Network Analyzer Used

Shipping calculated at checkout.
Calibrations
check availability
Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Additional Features:

  • 2-port, 30 kHz to 4.5 GHz or 8.5 GHz
  • Configurable test set (direct receiver access)
  • Wide output power range (-85 to > +16 dBm)
  • Fast measurement speed (22 ms @ full 2-port cal, 1601 points, 500 kHz IFBW)
  • Dynamic Range: 123 dB
  • Trace Noise: 0.003 dBrms
  • Harmonics: -25 dBc
  • Noise Floor: -128 dBm
  • Best Speed at 201 Point, 1 Sweep: 3 ms
  • High receiver sensitivity
  • 10.4" Color LCD with touch screen
  • Windows OS with LAN/USB/GPIB connectivity
  • Code compatibility with Agilent E5071C and 8753 Series
Share on
View full details

Applications

  • S-Parameters
  • Gain Compression
  • Far-Field/Near-Field Antenna Range
  • Return Loss
  • Insertion Loss/Gain

Components

  • Cables
  • Mixers/Frequency Converters
  • Amplifiers
  • Resonators
  • Antenna/Coil/RFIDs
  • Filters
  • LCR Components

The Agilent E5072A Network Analyzer, a member of the ENA Series has a more flexible platform and enhanced capabilities that can meet your evolving measurement needs in a wide range of applications (i.e. power amplifiers, high-power or high-rejection measurements). Improved performance of the Agilent E5072A exceeds what is possible with current RF network analyzers. The Agilent E5072A with a configurable test set provides access to the signal paths between the internal source, receivers, bridges, and the analyzer's test ports. This improves instrument sensitivity as well as adding the ability to add components or peripherals for a variety of applications.

The Agilent E5072A delivers new standards in versatility, speed and accuracy, and is suitable for full performance characterization of passive and active components, such as antennas, filters, and high-power amplifiers. The Agilent E5072A delivers the source power level up to +20 dBm from the test port. By eliminating additional booster amps, the Agilent E5072A can perform measurements of compression characteristics of active devices with a single power sweep.

The Agilent E5072A leverages all existing features of the 2-port Agilent E5071C. 100% code compatibility is guaranteed between the Agilent E5072A and the Agilent E5071C with fi rmware revision 9.61 or before. The Agilent E5072A also offers a powerful code emulation tool (cXL) for 8753ES, which can minimize your transition risk or cost from legacy network analyzers to the Agilent E5072A.

Model No

E5072A

Condition

Used

Manufacturer

Agilent

Frequency

8.5 GHz

8

Frequency offset mode

10

Time Domain Analysis

17

Removable Data Storage

19

Standard Data Storage

1CM

Rack mount kit

1CN

Front handle kit

1CP

Rack mount and front handle kit

100000

High stability timebase

240

2-port Test Set , 9 kHz to 4.5 GHz without Bias Tees

245

2-port Test Set , 100 kHz to 4.5 GHz with Bias Tees

260

2-port Test Set , 9 kHz to 6.5 GHz without Bias Tees

265

2-port Test Set , 100 kHz to 6.5 GHz with Bias Tees

280

2-port Test Set , 9 kHz to 8.5 GHz without Bias Tees

285

2-port Test Set , 100 kHz to 8.5 GHz with Bias Tees

2D5

2-port Test Set , 300 kHz to 14 GHz with Bias Tees

2K5

2-port Test Set , 300 kHz to 20 GHz with Bias Tees

440

4-port Test Set , 9 kHz to 4.5 GHz without Bias Tees

445

4-port Test Set , 100 kHz to 4.5 GHz with Bias Tees

460

4-port Test Set , 9 kHz to 6.5 GHz without Bias Tees

465

4-port Test Set , 100 kHz to 6.5 GHz with Bias Tees

480

4-port Test Set , 9 kHz to 8.5 GHz without Bias Tees

485

4-port Test Set , 100 kHz to 8.5 GHz with Bias Tees

4D5

4-port Test Set , 300 kHz to 14 GHz with Bias Tees

4K5

4-port Test Set , 300 kHz to 20 GHz with Bias Tees

810

Add keyboard

820

Add mouse

A6J

ANSI Z540-1-1994 Calibration

TDR

ENHANCED TIME DOMAIN ANALYSIS

UNQ