8 Input Channels (4 Currents/4 Voltages OR 8 Voltages)
Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
GPS time synchronization: Correlate data with events or datasets from other instruments with precision
Flexible and fully configurable thresholds and scale factors: Allows user to pinpoint specific issues by defining the detailed criteria for detection and recording of disturbances.
Uninterrupted power supply (40 minutes): Never miss important events - even record the beginning and end of interruptions and outages to help determine the cause
10 MHz, 6000 Vpk waveform capture: Get a detailed picture of even the shortest event
2 GB data memory: Enables detailed, simultaneous recording of numerous power parameters for long periods of time
Comprehensive software included: Provides trend diagrams for root cause analysis, statistical summaries, report writing and real-time data monitoring in the online mode
Plug and play: Allows quick setup with automatic sensor detection; sensors are instrument powered, eliminating the need for batteries
Rugged field design: Insulated housing and a solid state design with no rotating components enable reliable testing under nearly any conditions
Detailed disturbance analysis – Perform high-speed transient analysis and uncover root cause of equipment malfunction for later mitigation and predictive maintenance. The fast transient option, with its 6000 V measurement range, allows capture of very short impulses such as lightning strikes.
Class-A quality-of-service compliance – Validate incoming power quality at the service entrance. Thanks to Class A compliance, the Fluke 1760 allows undisputable verification.
Event correlation at multiple locations – Utilizing GPS time synchronization, users can quickly detect where a fault occurred first, either inside or outside the facility.
Galvanic separation and DC coupling – Allows complete measurements on dissimilar power systems. For example troubleshoot UPS systems by simultaneously recording the battery voltage and power output.
Power quality and power load studies – Assess baseline power quality to validate compatibility with critical systems before installation and verify electrical system capacity before adding loads.
Includes:
Internal Flash-memory 2 GB
PQ Analyze software on CD-ROM
Ethernet cable for network connection (1)
Crosslink Ethernet cable for direct PC connection (1)
Mains cable (1)
Operational manuals
Carrying bag
Fast transient analysis up to 10 MHz
The Fluke 1760 Three-Phase Power Quality Recorder is fully compliant to IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium- and low-voltage networks, this power quality monitor provides the flexibility to customize thresholds, algorithms, and measurement selections. The 1760 power recorder captures the most comprehensive details on user-selected parameters.