Features:

  • Frequency range: 10 kHz to 2.1 GHz
  • Resolution: 1 Hz
  • Display Accuracy: ±2 ppm (15° C TO 35° C) and ±10 PPM (0° to 50° C)
Share on
View full details

Frequency Stability

  • Stability vs Time: ±0.05 ppm/hour and ±2 ppm/90 days
  • Stability vs Temperature: ±2ppm (15° C to 35° C) and ±10 ppm (0° C to 50° C)
  • Stability vs Line Voltage: ±0.05 ppm for a 10% change in power source voltage
  • Stability vs Output Level: ±0.01 ppm

Spectral Purity

  • Harmonics: <-25dBc from <+13dBm @ <1057.5 MHz and <+7dBm @ >1057.5 MHz
  • Sub Harmonics: <-100dBc (to 132.1875 MHz), -90dBc (132.1875 MHz offset >10 kHz from carrier
  • Residual AM: <0.01% AMrms (0.3 to 3 kHz post-detection bandwidth)
  • Residual FM: <4 Hz (to 132.187 5 MHz), <2 Hz (132.1875 MHz to 1057.5 MHz), and <5 Hz (above 1057.5 MHz) in a 0.3 to 3 kHz post-detection noise bandwidth
  • SSB Phase Noise: -127dBc/Hz (to 132.1875 MHz), -134dBc/Hz (132.1875 MHz to 1057.5  MHz) and -125dBc/Hz (above 1057.5 MHz) measured in a 1 Hz bandwidth, offset 20 kHz from the carrier
  • Noise Floor: <-135dBc/Hz (to 132.187 5 MHz), <-140dBc/Hz (to 1057.5 MHz), and <-134dBc/Hz (to 2.0 GHz) at 3 MHz offset

RF Output Specifications

  • RF Output Level: Carrier level >+15dBm to -140dBm (all frequencies) and +18dbm down to -140dBm (<528.75 MHz)
  • Output Impedance: 50Ω nominal
  • Reverse Power Protection: 50 watts, 50 volts (to 1000 MHz) and 25 watts, 50 volts (above 1000 MHz)
  • VSWR: <1.5:1 (to 1000 MHz) and <2.5:1 (above 1000 MHz) when terminated in a 50 OHM resistive load
  • RF Output Connector: Female Type N coaxial connector
  • Output Level Resolution: 0.1dB
  • Output Leveling Flatness: ±1.5dB (to 500 MHz), ±2.0dB (500 MHz to 1000 MHz), and ±2.5dB (above 1000 MHz)
  • Attenuator Accuracy: ±2.0dB
  • Absolute Level Accuracy: ≤±0.1dB (-127 to +15dBm) and ≤3.5dB (<-127 to >+15dBm

The Agilent 8642M Signal Generator has a frequency range of from 100 kHz to 2 GHz and frequency resolution of 1 Hz at all frequencies. The output is leveled and calibrated from +15dBm to -140dBm at all frequencies. Amplitude Modulation, Frequency Modulation, and Pulse Modulation modes are selectable. Frequency, modulation modes, output level, and most other functions can be remotely programmed via the interface.

Model No

8642M

Condition

Used

Manufacturer

Agilent

Frequency

2.1 GHz