Skip to content

The Agilent E4432A, also designated the ESG-D3000A, is a digital RF signal generator covering 250 kHz to 3000 MHz. It produces continuous-wave and digitally modulated RF signals with 0.01 Hz frequency resolution and a calibrated output that reaches +13 dBm at the low end of its band, serving as a programmable source for stimulus-response measurements across the HF through microwave spectrum.
An RF signal generator supplies a known, controllable carrier that a device under test can be measured against; without a clean reference signal, characterizing receivers, amplifiers, and communication subsystems is not possible. The E4432A extends this role into the digital domain through its optional internal baseband generator, which supports the DECT, GSM (including DCS1800/PCS1900), NADC, PDC, PHS, and TETRA formats and generates the framed, filtered, and bursted waveforms those standards define.
ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments we list are equipment we physically keep on hand. Every used unit is inspected and functionally verified in-house against the manufacturer's published specifications before it ships, while new units leave factory-sealed exactly as received.
This instrument carries Agilent Technologies branding, the test-and-measurement business that Hewlett-Packard spun off as a separate company in 1999. In 2014 that test-and-measurement business was established as Keysight Technologies, the name under which the line is supported today.
| Specification | Value |
|---|---|
| Frequency | |
| Frequency Range (Agilent ESG-D3000A) | 250 kHz to 3000 MHz |
| Resolution | 0.01 Hz |
| Switching Speed (Modulation On) | <45 ms, typical |
| Switching Speed (Modulation Off) | <35 ms, typical |
| Accuracy | Same as timebase |
| Sweep Modes | |
| Operating modes | Step: frequency & power, and arbitrary list |
| Dwell Time | 2 ms to 60 sec |
| Number of Points | 2 to 401 |
| Internal Reference Oscillator | |
| Aging Rate (Standard) | <±2 ppm/yr |
| Aging Rate (High Stability, Opt 1E5) | <±0.1 ppm/yr or <±0.0005 ppm/day after 45 days |
| Temperature (Standard) | <±1 ppm |
| Temperature (High Stability, Opt 1E5) | <±0.05 ppm, typical (0° to 55° C) |
| Line Voltage (Standard) | <±0.1 ppm (+5%, -10%) |
| Line Voltage (High Stability, Opt 1E5) | <±0.002 ppm, typical (+5%, -10%) |
| Timebase Reference Output Frequency | 10 MHz |
| Timebase Reference Output Amplitude | >0.35 Vrms into 50 ohm load |
| External Reference Input Frequency | 1, 2, 5, 10 MHz ± typ. 10 ppm (Option 1E5: 1 ppm, typical) |
| External Reference Input Amplitude | >0.15 Vrms |
| External Reference Input Impedance | 50 ohm |
| Output | |
| Range (250 kHz to 1000 MHz) | +13 to -136 dBm |
| Range (>1000 MHz to 3000 MHz) | +10 to -136 dBm |
| Range (>3000 MHz to 4000 MHz) | +7 to -136 dBm |
| Resolution | 0.02 dB |
| Level Accuracy (+7 to -127 dBm, 250 kHz to 2 GHz) | ±0.5 dB |
| Level Accuracy (+7 to -127 dBm, 2 GHz to 4 GHz) | ±0.9 dB |
| Level Accuracy (<-127 dBm, 250 kHz to 2 GHz) | ±1.5 dB |
| Level Accuracy (<-127 dBm, 2 GHz to 4 GHz) | ±2.5 dB |
| Attenuator Hold Level Range | >17 dB |
| Switching Speed | <25 ms typical |
| Switching Speed (With Power Search Mode) | <210 ms typical |
| Reverse Power Protection (250 kHz to 2000 MHz) | 50 Watts |
| Reverse Power Protection (>2000 MHz to 4000 MHz) | 25 Watts |
| Max DC Voltage | 50 V |
| SWR (typical, 250 kHz to 2000 MHz) | <1.4:1 |
| SWR (typical, >2000 to 4000 MHz) | <1.9:1 |
| Output Impedance | 50 ohms |
| Level Accuracy with Digital Modulation | |
| pi/4 DQPSK or QPSK Formats | ±0.15 dB (with raised cosine or root-raised cosine filter and alpha >=0.35; with 10 kHz |
| Constant Amplitude Formats (FSK, GMSK, etc.) | no degradation in power level accuracy |
| Level Accuracy with ALC Off | ±0.5 dB, typical |
| Spectral Purity | |
| SSB Phase Noise (typical, 20 kHz offset) at 500 MHz | <-120 dBc/Hz |
| at 1000 MHz | <-116 dBc/Hz |
| at 2000 MHz | <-110 dBc/Hz |
| at 3000 MHz | <-104 dBc/Hz |
| at 4000 MHz | <-104 dBc/Hz |
| Residual FM (Phase Noise Mode 1) | |
| Residual FM (Phase Noise Mode 2) | |
| Harmonics (<=+4 dBm output level) | <-30 dBc |
| Nonharmonics (250 kHz to 1000 MHz) | <-65 dBc |
| Nonharmonics (>1000 MHz to 2000 MHz) | <-59 dBc |
| Nonharmonics (>2000 MHz) | <-53 dBc |
| Subharmonics (<=1000 MHz) | None |
| Subharmonics (>1000 MHz) | <-40 dBc |
| IQ Modulation | |
| I&Q Inputs Impedance | 50 ohms |
| Full Scale Input | [square root of (I2 + Q2)] = 0.5 Vrms |
| External Input RF Bandwidth (1 dB) | 20 MHz, typical |
| DC Offset (I + Q independently adjustable) | ±100% |
| I/Q Gain Ratio | ±4 dB |
| Static EVM (rms) <0.6 GHz | <0.75% |
| Static EVM (rms) 0.6 to 2 GHz | <0.5% |
| Static EVM (rms) 2 to 3.7 GHz | 0.75% |
| Static EVM (rms) <=4 GHz | <1% |
| Magnitude Error (rms) <0.6 GHz | <0.5% |
| Magnitude Error (rms) 0.6 to 2 GHz | <0.35% |
| Magnitude Error (rms) 2 to 3.7 GHz | <0.5% |
| Magnitude Error (rms) <=4 GHz | <0.75% |
| Phase Error (rms) <0.6 GHz | <0.35° |
| Phase Error (rms) 0.6 to 2 GHz | <0.25° |
| Phase Error (rms) 2 to 3.7 GHz | <0.35° |
| Phase Error (rms) <=4 GHz | <0.5° |
| Origin Offset (dBc) <0.6 GHz | <-46 |
| Origin Offset (dBc) 0.6 to 2 GHz | <-46 |
| Origin Offset (dBc) 2 to 3.7 GHz | <-40 |
| Origin Offset (dBc) <=4 GHz | <-40 |
| Frequency Modulation | |
| Maximum Deviation | N x 10 MHz |
| Resolution | 0.1% of deviation or 1 Hz, whichever is greater |
Deviation Accuracy (1 kHz rate, dev. | <±(3.5% of FM deviation + 20 Hz) | |
| FM1 1 dB Bandwidth | dc/20 Hz to 100 kHz |
| FM1 3 dB Bandwidth, typical | dc/5 Hz to 10 MHz |
| FM2 1 dB Bandwidth | dc/20 Hz to 100 kHz |
| FM2 3 dB Bandwidth, typical | dc/5 Hz to 1 MHz |
| Distortion (1 kHz rate, THD, dev. = N x 100 kHz) | <1% |
| Phase Modulation | |
| Maximum Deviation | N x 90 radians |
| Resolution | 0.1% of set deviation |
| Deviation Accuracy (1 kHz rate) | <±(5% of deviation + 0.01 radians) |
| PM1 Normal BW (N x 90 rad) | dc to 100 kHz |
| PM2 Normal BW (N x 90 rad) | dc to 100 kHz |
| PM1 High BW (N x 2pi rad) | dc to 1.5 MHz (typ) |
| PM2 High BW (N x 2pi rad) | dc to 1 MHz (typ) |
| PM1 High BW (N x pi/2 rad) | dc to 4 MHz (typ) |
| PM2 High BW (N x pi/2 rad) | dc to 0.9 MHz (typ) |
Distortion (1 kHz rate, THD, dev | <1% | |
Important: Reverse power protection: 50 W from 250 kHz to 2000 MHz and 25 W from 2000 MHz to 4000 MHz, with a maximum DC voltage of 50 V.
Important: Level Accuracy degrades by 0.02 dB/°C over the full temperature range and by 0.3 dB above +7 dBm.
Important: DC Vector Accuracy specifications are valid for 10 days after executing the internal calibration routine, provided temperature is maintained within ±5° C of calibration temperature.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Agilent
Condition
Pre-Owned
Manufacturer
Agilent
Rf_gen_freq
250 kHz to 3000 MHz
100000
High-stability timebase
UN4
I/Q Baseband Generator with 8 Mbit Pattern RAM