Key Features At A Glance

  • Frequency range 250 kHz to 1000 MHz with 0.01 Hz resolution
  • Output level range +13 to -136 dBm at 0.02 dB resolution
  • AM, FM, phase, and pulse modulation with an internal modulation source
  • SSB phase noise <-120 dBc/Hz at 500 MHz (typical, 20 kHz offset)
  • HP-IB (IEEE-488.2) and RS-232 remote control with SCPI 1992.0
  • Optional high-stability timebase (Opt 1E5): aging <±0.1 ppm/yr
  • Reverse power protection to 50 W max and 50 V dc max
  • Conducted/radiated interference meets MIL-STD-461B RE02 Part 2 and CISPR 11
View full details

The Agilent E4400A is an analog RF signal generator covering 250 kHz to 1000 MHz, also identified as the Agilent ESG-1000A. It produces calibrated RF output across that span with 0.01 Hz frequency resolution, and pairs that frequency agility with a broad amplitude range and a full suite of analog modulation modes driven from an internal source.

An analog RF signal generator supplies a known, controllable RF stimulus so that an engineer can drive a device under test and measure its response. It serves as the source half of a stimulus-response test setup, generating carrier signals at defined frequencies, levels, and modulation states for bench and system measurements.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house against the original manufacturer specifications before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

This instrument carries Agilent branding from the era when Hewlett-Packard spun off its test and measurement business as Agilent Technologies in 1999. Agilent's electronic measurement division later became Keysight Technologies in 2014.

Product Core & Specifications

Specification Value
Frequency
Frequency Range (Agilent ESG-1000A) 250 kHz to 1000 MHz
Resolution 0.01 Hz
Switching Speed Modulation On: <45 ms, typical; Modulation Off: <35 ms, typical
Accuracy Same as timebase
Sweep Modes
Operating modes Step: frequency & power, and arbitrary list
Dwell Time 2 ms to 60 sec
Number of Points 2 to 401
Internal Reference Oscillator
Aging Rate (Standard, typical) <±2 ppm/yr
Aging Rate (High Stability, Opt 1E5) <±0.1 ppm/yr or <±0.0005 ppm/day after 45 days
Temperature (Standard) <±1 ppm
Temperature (High Stability, Opt 1E5) <±0.05 ppm, typical (0° to 55°C)
Line Voltage (Standard) <±0.1 ppm (+5%, -10%)
Line Voltage (High Stability, Opt 1E5) <±0.002 ppm, typical (+5%, -10%)
Timebase Reference Output
Frequency 10 MHz
Amplitude >0.35 Vrms into 50 ohm load
External Reference Input
Frequency 1, 2, 5, 10 MHz ± typ. 10 ppm; Option 1E5: 1 ppm, typical
Amplitude >0.15 Vrms
Input Impedance 50 ohm
Output
Range 250 kHz to 1000 MHz: +13 to -136 dBm
Resolution 0.02 dB
Level Accuracy (at 23 ±5°C), +7 to -127 dBm 250 kHz to 1 GHz: ±0.5 dB
Level Accuracy (at 23 ±5°C), <-127 dBm 250 kHz to 1 GHz: ±1.5 dB
Attenuator Hold Level Range >17 dB
Switching Speed <25 ms typical; With Power Search Mode: <210 ms typical
Reverse Power Protection 250 kHz to 1000 MHz: 50 Watts; Max dc Voltage: 50 V
SWR (typical) 250 kHz to 1000 MHz: <1.4:1
Output Impedance 50 ohms
Level Accuracy footnote Accuracy degrades by 0.02 dB/°C over full temperature range and by 0.3 dB above +7 dBm.
Frequency Bands
Band 1 250 kHz to <=249.999 MHz; N# 1
Band 2 >249.999 to <=500 MHz; N# 0.5
Band 3 >500 MHz to <=1 GHz; N# 1
Spectral Purity
SSB Phase Noise (typical, at 20 kHz offset) at 500 MHz: <-120 dBc/Hz; at 1000 MHz: <-116 dBc/Hz
Residual FM (CW mode, 0.3-3 kHz BW, CCITT, rms) Phase Noise Mode 1:
Harmonics (<=+4 dBm output level) <-30 dBc
Nonharmonics (>3 kHz offset, <+7 dBm output level) 250 kHz to 1000 MHz: <-65 dBc
Subharmonics (<=1000 MHz) None
Frequency Modulation
Maximum Deviation N x 10 MHz
Resolution 0.1% of deviation or 1 Hz, whichever is greater
Deviation Accuracy (1 kHz rate, dev. <±(3.5% of FM deviation + 20 Hz)
Modulation Frequency Response (deviation = 100 kHz), FM1 1 dB BW: dc/20 Hz to 100 kHz; 3 dB BW, typical: dc/5 Hz to 10 MHz
Modulation Frequency Response (deviation = 100 kHz), FM2 1 dB BW: dc/20 Hz to 100 kHz; 3 dB BW, typical: dc/5 Hz to 1 MHz
Distortion (1 kHz rate, THD, dev. = N x 100 kHz) <1%
Phase Modulation
Maximum Deviation N x 90 radians
Resolution 0.1% of set deviation
Deviation Accuracy (1 kHz rate) <±(5% of deviation + 0.01 radians)
Modulation Frequency Response, Normal BW (N x 90 rad) PM1: dc to 100 kHz; PM2: dc to 100 kHz
Modulation Frequency Response, High BW (N x 2 pi rad) PM1: dc to 1.5 MHz (typ); PM2: dc to 1 MHz (typ)
Modulation Frequency Response, High BW (N x pi/2 rad) PM1: dc to 4 MHz (typ); PM2: dc to 0.9 MHz (typ)
Distortion (1 kHz rate, THD, dev <1%
Amplitude Modulation (fc>500 kHz)
Range (envelope peak <=max specified power) 0 to 100%
Resolution 0.1%
Rates (3 dB Bandwidth) dc/10 Hz to 10 kHz
Distortion (1 kHz rate, THD), 30% AM <1.5%
Distortion (1 kHz rate, THD), 90% AM <4%
Accuracy (1 kHz rate) <±(5% of setting + 1%)
Pulse Modulation
On/Off Ratio (<=1 GHz) >80 dB
Rise/Fall Times 150 ns, typical
Minimum Width (typical) ALC On: 2 µs; ALC Off: 0.4 µs
Pulse Repetition Frequency (typical) ALC On: 10 Hz to 250 kHz; ALC Off: DC to 1.0 MHz
Level Accuracy (relative to CW) ± 0.5 dB, typical
Internal Pulse Generator (Squarewave only)
Squarewave Rates 0.1 Hz to 50 kHz
Pulse Period 16 µs to 30 seconds
Width 8 µs to 30 seconds
Resolution 4 µs
Internal Modulation Source
Provides FM, PM, and AM Modulation Signals and LF Out
Waveforms sine, square, ramp, triangle, pulse, noise
Rate Range Sine: 0.1 Hz to 50 kHz; Square, Ramp, Triangle: 0.1 Hz to 10 kHz; Pulse: 4 µs
Resolution 0.1 Hz
Frequency Accuracy 0.005%
Swept Sine Mode (Frequency, Phase Continuous), Operating Modes Triggered or Continuous Sweeps
Swept Sine Mode, Frequency Range 0.1 Hz to 50 kHz
Swept Sine Mode, Sweep Time 1 ms to 65 seconds
Swept Sine Mode, Resolution 1 ms
Dual Sinewave Mode, Frequency Range 0.1 Hz to 50 kHz
Dual Sinewave Mode, Amplitude Ratio 0 to 100%
Dual Sinewave Mode, Amplitude Resolution 0.1%
LF Out (Internal Modulation Source)
Amplitude 0 to 3 Vpeak into 50 ohms
Output Impedance <1 ohm
External Modulation Inputs
Modulation Types Ext1: FM, PM, AM, and Burst Envelope; Ext2: FM, PM, AM, and Pulse
Simultaneous Modulation All modulation types may be simultaneously enabled, except: FM with PM, AM with Burst. AM, FM, and PM can sum simultaneous inputs from any two sources (INT, EXT1, and EXT2.) Any given source (INT, EXT1, or EXT2) may only be routed to one activated modulation type.
Remote Programming
Interface HP-IB (IEEE-488.2-1987) with Listen and Talk, RS-232
Control Languages SCPI version 1992.0, also compatible with Agilent 8656B & 8657A/B/D/J mnemonics
Functions Controlled All front panel functions except power switch and knobs
IEEE-488 Functions SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT0, C0, E2
General
Power Requirements 90 to 254 V; 50, 60, or 400 Hz; 200 W maximum
Operating Temperature Range 0 to 55° C
Leakage Conducted and radiated interference meets MIL-STD-461B RE02 Part 2 and CISPR 11
Important: Reverse power protection: 50 W maximum, 50 V dc maximum.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Agilent

Rf_gen_freq

250 kHz to 1000 MHz