The Keysight E36300 Series is a line of triple-output bench DC power supplies built for the test bench. Keysight positions the series to deliver the performance of system power supplies at an affordable bench price, combining low output ripple and noise with accurate voltage and current programming and readback so a design can be powered and measured with confidence.
A bench DC power supply provides controlled, regulated voltage and current to a device under test. The E36300 Series is suited to powering precision circuitry, where its low normal-mode noise assures quality power, and to powering multiple analog or digital circuits or devices from a single instrument. Its built-in OVP, OCP, and OTP protection supports limit testing while helping prevent damage to the DUT.
The E36312A and E36313A extend into design characterization workflows—emulating the behavior of power subsystems early in the design process, controlling multiple voltage sequences, measuring wide dynamic ranges of current, and varying voltage speed to reflect real circuit characteristics.
ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.
Keysight Technologies traces its measurement heritage through Hewlett-Packard, whose test and measurement business was spun off as Agilent Technologies in 1999. Agilent's electronic measurement group then became the independent Keysight Technologies in 2014, the brand under which this product line is sold today.
The E36300 Series comprises three triple-output bench power supplies that share a common architecture but scale in capability. Keysight describes the line as delivering the performance of system power supplies at an affordable bench price, packaging three outputs — a 6 V rail and two 25 V rails — into a single instrument across all three models.
The series comparison distinguishes the E36311A as the 80 W economy model, the E36312A as the 80 W full-featured model, and the E36313A as the 160 W high-current model. The sections below summarize how the models differ; the comparison table that follows lists the per-model specifications in full.
Each new model below is listed as its own dedicated product page with condition-matched pricing. Select the model that fits your output and feature requirements, then choose the available condition and configuration on that model's page.
The E36311A is the 80 W economy model: its channels 2 and 3 operate in tracking mode only, it provides 2-wire sensing and a USB interface, and it does not offer data logging, output sequencing, LIST mode, or auto series/parallel voltage and current boost. The E36312A is the 80 W full-featured model, adding electrically isolated independent channels 2 and 3, 2- or 4-wire sensing, USB and LAN with optional GPIB, data logging, output sequencing, LIST mode, and auto series/parallel operation.
The E36313A is the 160 W high-current model, offering twice the current of the other two — 10 A on the 6 V rail and 2 A on each 25 V rail — while carrying the same extended feature set as the E36312A. On the E36312A and E36313A, auto series/parallel lets channels 2 and 3 combine to reach up to 50 V or up to 4 A. The comparison table details each model's outputs, regulation, accuracy, and interface options.
| Model | Total Power | Output 1 | Outputs 2 & 3 |
|---|---|---|---|
| E36312A | 80 W | 6 V, 5 A | 2 x 25 V, 1 A |
| E36311A | 80 W | 6 V, 5 A | ±25 V, 1 A |
| E36313A | 160 W | 6 V, 10 A | 2 x 25 V, 2 A |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Output (0 to 40 °C) | |
| Power output | 80 W |
| Channel 1 | 0 to 6 V, 0 to 5 A |
| Channel 2 | 0 to 25 V, 0 to 1 A |
| Channel 3 | 0 to 25 V, 0 to 1 A |
| Series mode voltage | 50 V |
| Parallel mode current | 2 A |
| Load Regulation ± (% of output + offset) | |
| Voltage | < 0.01% + 2 mV |
| Current | < 0.01% + 250 µA |
| Line Regulation ± (% of output + offset) | |
| Voltage | < 0.01% + 1 mV |
| Current | < 0.01% + 250 µA |
| Output Ripple and Noise (20 Hz to 20 MHz) | |
| Normal mode voltage | < 350 µVrms / 2 mVpp |
| Normal mode current (per channel, CH1 / CH2 / CH3) | < 2 mArms / 1 mArms / 500 µArms |
| Programming Accuracy, 12 Months (23 °C ± 5 °C) ± (% of output + offset) | |
| Voltage (6 V output) | 0.03% + 2 mV |
| Voltage (25 V outputs) | 0.03% + 5 mV |
| Current (6 V output) | 0.04% + 3 mA |
| Current (25 V outputs) | 0.04% + 2 mA |
| Readback Accuracy, 12 Months (23 °C ± 5 °C) ± (% of output + offset) | |
| Voltage (6 V output) | 0.04% + 2 mV |
| Voltage (25 V outputs) | 0.04% + 5 mV |
| Current (6 V output) | 0.04% + 3 mA |
| Current (25 V outputs) | 0.04% + 3 mA |
| Low range current | 0.25% + 80 µA |
| Resolution (Typical, Front Panel) | |
| Programming voltage | 1 mV |
| Programming current | 1 mA |
| Readback voltage | 10 mV / 1 mV |
| Readback current | 1 mA |
| Overvoltage Protection (OVP) ± (% of output + offset) | |
| Programming accuracy (6 V output) | 0.20% + 0.1 V |
| Programming accuracy (25 V outputs) | 0.20% + 0.4 V |
| Activation Time | |
| Overvoltage (OVP) | < 5 ms |
| Overcurrent (OCP) | < 5 ms |
| Command processing time | < 10 ms |
| Programming Temperature Coefficient per °C (% of output + offset) | |
| Voltage (6 V output) | 0.01% + 0.18 mV |
| Voltage (25 V outputs) | 0.01% + 0.6 mV |
| Current (per channel, CH1 / CH2 / CH3) | 0.01% + 0.25 mA / 0.01% + 0.2 mA / 0.01% + 0.1 mA |
| Readback Temperature Coefficient per °C (% of output + offset) | |
| Voltage | 0.01% + 20 µV / 0.01% + 40 µV |
| Current (per channel, CH1 / CH2 / CH3) | 0.01% + 0.25 mA / 0.01% + 0.2 mA / 0.01% + 0.1 mA |
| Up/Down Programming Settling Time (to within 1% of total excursion) | |
| Up, full load (6 V / 25 V) | 11 msec / 50 msec |
| Up, no load (6 V / 25 V) | 10 msec / 20 msec |
| Down, full load (6 V / 25 V) | 13 msec / 45 msec |
| Down, no load (6 V / 25 V) | 100 msec / 150 msec |
| Remote sense (max. voltage in load lead) | 1 V |
| Load Transient Recovery Time | |
| Voltage settling band | 15 mV |
| Voltage settling band (parallel mode) | 30 mV |
| Time | < 50 µS |
| Interface Capabilities | |
| GPIB | SCPI – 1999, IEEE 488.2 compliant interface |
| LXI compliance | Class C |
| USB 2.0 | Requires Keysight IO Library version 17.2.208 and up |
| 10/100 LAN | Requires Keysight IO Library version 17.2.208 and up |
| Digital Control Characteristics | |
| Maximum voltage ratings | +16.5 VDC / -5 VDC between pins (pin 4 is internally connected to chassis ground) |
| Pins 1 and 2 as Fault output | Maximum low-level output voltage = 0.5 V @ 4 mA; Maximum low-level sink current = 4 mA; Typical high-level leakage current = 1 mA @ 16.5 VDC |
| Pins 1 - 3 as digital/trigger outputs (pin 4 = common) | Maximum low-level output voltage = 0.5 V @ 4 mA; 1 V @ 50 mA; 1.75 V @ 100 mA; Maximum low-level sink current = 100 mA; Typical high-level leakage current = 0.8 mA @ 16.5 VDC |
| Pins 1 - 3 as digital/trigger inputs and pin 3 as inhibit input (pin 4 = common) | Maximum low-level input voltage = 0.8 V; Minimum high-level input voltage = 2 V; Typical low-level current = 2 mA @ 0 V (internal 2.2 k pull-up); Typical high-level leakage current = 0.12 mA @ 16.5 VDC |
| Environmental Conditions | |
| Operating environment | Indoor use, installation category II (for AC input), pollution degree 2 |
| Operating temperature range | 0 to 40 °C |
| Storage temperature | -20 to 70 °C |
| Relative humidity | Up to 95% |
| Altitude | Up to 2000 meters |
| Electromagnetic compatibility | Compliant with EMC Directive (2004/108/EC); IEC 61326-1:2012/EN 61326-1:2013 Group 1 Class A; Canada: ICES-001:2004; Australia/New Zealand: AS/NZS; South Korea KC mark |
| Safety | UL 61010-1 3rd edition; CAN/CSA-C22.2 No. 61010-1-12; IEC 61010-1:2010 3rd edition |
| AC Input | |
| Input | 100, 115, or 230 V input (±10%), 50/60 Hz, 250 VA |
| General | |
| Net weight | 8.3 kg |
| Overall dimension (H x W x D) | 145 x 216 x 367 mm |
| Net dimension without feet, strap handle, and GPIB module (H x W x D) | 133 x 213 x 364 mm |
Important: Data logging on the E36312A and E36313A requires an external USB memory device to start.
Important: The recessed binding post option (Opt. RBP) provides complete insulation of front panel connections for extra safety and is not upgradable; it must be ordered with the instrument.
Important: Data logging, output sequencing, and LIST mode are available on the E36312A and E36313A models only; the E36311A does not offer these features.
Important: All specifications are not applicable during auto series/parallel mode.
Usage tip: pair the E36312A or E36313A with Keysight BenchVue (BV0003B Power Supply Control & Automation) to connect, control, log data, and capture screenshots from multiple supplies without programming.
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Keysight
Condition
Factory New
Manufacturer
Keysight Technologies
Dcsup_amps
5 A, 1 A
Dcsup_volts
6 V, 25 V
Dcsup_watts
80 W
GPB
GPIB interface module
Request A Quote