Skip to content
The unit uses dual voltage ranges and programmable current limits to protect the unit under test. Standard voltage ranges of 135 and 270 Volt RMS are typical but optional output range options offer voltage ranges up to 400 V RMS. The complete solid state, high switching speed PWM architecture of the L Series ensures low noise and low distortion output over a wide range of power levels. Line input is 115 V or 230 V L-N, 1 phase 47 - 400 Hz.
Model No
2001L
Condition
Used
Manufacturer
California Instruments
Frequency
5 kHz
Phase
1
Power (va)
2 kVA
Volts
135 V
1
Single phase input
EHV
Extra high voltage. Changes output transformer to 200 V/ 400 V , L-N (45 Hz to 1000 Hz frequencies only).
PT
Controller is recommended for applications