  • Maximum non-destructive input voltage of 500 V DC + peak AC
  • Selectable 10x or 100x attenuation factor, switched simultaneously on both probes via a shared compensation box
  • Passive, matched differential probe pair designed for use with DA1800 series differential amplifiers
  • Probe bandwidth DC to 250 MHz (-3 dB); system bandwidth 100 MHz with DA1855A, 10 MHz with DA1822
  • 1 MΩ ±1% input resistance with 10.5 pF ±0.5 pF input capacitance
  • Usable with any oscilloscope or plug-in offering 1 MΩ / 15-26 pF input and one-inch (25.4 mm) connector spacing
  • Compensation box enables transient-response matching and CMRR optimization
  • 1.2 meter cable length
View full details

The DXC100A is a high-performance, passive, matched, differential probe pair designed for use with the DA1800 series differential amplifiers. The probe pair consists of two highly matched individual probes that share a common compensation box, allowing the attenuation factor on both probes to be switched simultaneously between 10x and 100x. This shared-compensation design keeps the two probe channels balanced as a single differential pair rather than two independently adjusted single-ended probes.

When the DXC100A is used with the DA1822 or DA1855A differential amplifier, the probe's attenuation factor is automatically incorporated into the effective gain display and into the location of the decimal in the voltage generator display. Although primarily intended for the differential amplifiers, the probe pair can also be used with any oscilloscope or plug-in unit that provides an input impedance of 1 MΩ / 15-26 pF and one inch (25.4 mm) spacing between connectors. When used on a differential amplifier, the compensation box allows for precise adjustment and matching of the transient response and optimization of the system Common Mode Rejection Ratio (CMRR).

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit we offer is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Product Core & Specifications

Specification Value
General
Attenuation factor 10 or 100
Bandwidth (-3 dB) 250 MHz
System Bandwidth (-3 dB) (with DA1855) 100 MHz
System Bandwidth (-3 dB) (with DA1822) 10 MHz
System Risetime (with DA1855) 3.5 ns
System Risetime (with DA1822) 35 ns
Input Resistance 1 MΩ ± 1%
Input Capacitance 10.5 pF ± 0.5 pF
Compensation 15 to 26 pF
Maximum non-destructive Input Voltage 500 V DC + peak AC
Length 1.2 meter
Environmental Characteristics
Operating Range 0° to 50°C
Non-Operating -4° to 75°C
Physical Characteristics
Weight 0.21 kg (0.47 lb)
Shipping Weight 0.45 kg (1 lb)
Warranty 1 year
Important: Maximum non-destructive input voltage: 500 V DC + peak AC.
Important: The DXC100A can be used with any oscilloscope or plug-in unit having an input impedance of 1 MΩ / 15-26 pF and one inch (25.4 mm) spacing between connectors.
Recommended pairing: designed for use with the DA1800 series differential amplifiers; with the DA1822 or DA1855A, the attenuation factor is automatically incorporated into the amplifier's effective gain display.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

DXC100A

Condition

Pre-Owned

Diff_probe_freq

250 MHz

Length_meter

1.2 meter