Key Features At A Glance

  • 8 input channels for single- and three-phase power monitoring (4 voltage, 4 current)
  • Continuous recording up to 88 hours at 6,250 samples/sec per channel
  • Transients, glitches and disturbances captured at 200 kHz per channel
  • AstroPower software measures RMS voltage/current, real and reactive power, power factor and THD
  • 15-inch color resistive touch-screen at 1024 x 768 for on-site setup and analysis
  • Modular isolated inputs: IHV2 module rated 600 Vrms CAT II / 300 Vrms CAT III
  • 73 GB internal drive; auto-configures for single-phase, split-phase, Delta or Wye recording
  • Channels 7 & 8 usable as auxiliary inputs for tachometer, thermocouple, and AC/DC signals
View full details

The Astro-Med Dash 8XPM combines power monitoring and data acquisition in one system. It pairs the data acquisition recording of the Dash 8Xe with AstroPower monitoring software, delivering the capabilities of a high-end data acquisition recorder and a dedicated power monitoring system in a single portable tool. Using the standard Dash 8Xe software the system operates as a data acquisition recorder; switching to AstroPower software turns it into a power quality and disturbance monitor that can record power trends, events and transients for days, weeks or months at a time.

A power monitoring recorder logs electrical signals over time so that intermittent disturbances can be identified and analyzed after the fact. The Dash 8XPM is used to monitor power quality and the disturbances that can disrupt the operation of electrical equipment, logging power interrupts, sags, swells, frequency deviations, harmonics, interharmonics and unbalances. Running the standard Dash 8Xe software, it also serves as a data acquisition recorder for long-term trend recording, traditional data capture, and oscilloscope recording for maintenance troubleshooting applications. Because review and analysis require no PC, the system works as an on-site troubleshooting tool.

ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us ship from instruments we physically hold rather than source on demand. Every pre-owned unit is handled to a consistent standard: pre-owned units are inspected and functionally verified in-house before shipment, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

This instrument is built by Astro-Med, Inc., a Rhode Island-based manufacturer that is system certified to ISO 9001. Astro-Med, Inc. adopted the corporate name AstroNova, Inc. in 2016.

Compare Other Models in This Series

The Dash 8XPM belongs to Astro-Med's Dash line of portable, hard-drive-based recorders that capture data directly to an internal disk for later review and analysis. Within that line, the Dash 8XPM is distinguished by combining the data acquisition functionality of the Dash 8Xe with AstroPower monitoring software, so a single unit performs both general data acquisition recording and dedicated power-quality monitoring.

Other recorders in the Dash line share the same direct-to-disk recording approach but differ in channel count, input type, and sample rate. The selection across the line spans modular-input and universal-input designs and a range of per-channel sample rates, allowing the recorder to be matched to the signal type and speed of the application.

Each model listed below is its own dedicated product page with condition-matched pricing, so the pre-owned unit you select is priced and described for that specific configuration. Choose the model that matches your channel count, input type, and recording-speed requirements, then select the listing for the condition you need.

What sets the Dash 8XPM apart within the Dash line is its dual role: it provides the Dash 8Xe's data acquisition recording while adding AstroPower software for power monitoring. That combination lets one instrument capture continuous power trends at 6,250 samples per second per channel, log power events, and capture transients at 200 kHz per channel, alongside traditional trend recording and oscilloscope recording for maintenance troubleshooting.

The Dash recorders differ primarily in channels, input type, and sample rate. The Dash 8Xe offers 8 channels of modular inputs with data acquisition to its internal hard drive at a 200 kHz sample rate per channel. The Dash 18X offers 18 channels of universal inputs at a 100 kHz sample rate per channel. The Dash 8HF offers 8 channels of analog inputs at a 2 MHz sample rate with 200 kHz bandwidth.

The Dash 8XPM itself provides 8 channels (4 voltage and 4 current when no auxiliary channels are used), continuous recording at 6,250 samples per second per channel for up to 88 hours, and transient capture at 200,000 samples per second per channel, with AstroPower power-monitoring software included. Refer to the comparison table for the channel, input-type, and sample-rate values that distinguish each model.

Model Max Voltage Bandwidth Channels
Dash 8XPM 8 (4 voltage, 4 current)
IHV1 250Vrms CAT II 39 kHz
IHV2 600Vrms CAT II, 300Vrms CAT III 34 kHz

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • AstroPower Review offline analysis package (included)
  • AstroPower power monitoring software
  • Dash 8Xe data acquisition software (standard)

Product Core & Specifications

Specification Value
Color Display
Display Full screen waveform or split screen w/analysis
Waveform display Voltage/current or phase groups
Viewing area 15-inch diagonal with 1024 x 768 resolution
Touch screen Full-screen, resistive
Signal Modules
Maximum modules 8 per unit
Supported modules IHV1 – voltage/current phase; IHV2 – voltage phase
Channels 4 voltage, 4 current (when no auxiliary channels are used)
Auxiliary channels Modules 7 and 8
IHV1 Module
Maximum voltage 250Vrms CAT II
Bandwidth 39 kHz
IHV2 Module
Maximum voltage 600Vrms CAT II, 300Vrms CAT III
Bandwidth 34 kHz
Continuous Recording
Recording method Internal disk drive
Sample rate 6,250 samples per second per channel
Drive capacity 73 GByte
Continuous Recording time up to 88 hours (dependent on free disk space)
Recorder Mode
Analysis Real-time calculations
Continuous recording All waveforms with one-button start/stop
Event logging Simultaneous with continuous waveform recording
Review Mode
Analysis Post-capture calculations
Derived channels Graphic plots of trend data. Includes Vrms, Irms, apparent power, real power, reactive power, power factor, frequency, THD, voltage unbalance and current unbalance
Transient Mode
Sample rate 200,000 samples per second per channel
Event Logging Yes
Logged Event Types – Voltage Interrupt, sag, swell, transient, frequency, total harmonic distortion, individual harmonic, individual interharmonic, unbalance
Logged Event Types – Current Transient, RMS thresholds, total harmonic distortion, individual harmonic, individual interharmonic, unbalance
Logged Event Types – Power Power factor, absolute power, active power, reactive power, leading/lagging
Analysis Functions
Harmonics/Interharmonics Graphical display for any phase (voltage or current); total harmonic distortion percentage
Phase diagrams Vector diagrams for voltage and current
RMS values Calculated for all phases, voltage and current
Power values Absolute power (kVA), active power (kW), reactive power (kVAR) and power factor
Sequential components Positive, negative, and zero sequence; voltage or current; percentage unbalanced
Power
Input Voltage Range 102 to 264 VAC
Frequency Range 47 Hz to 63 Hz
Power Factor 0.99
Power Consumption 150 W maximum (<100 W typical)
Physical
Enclosure Aluminum
Dimensions 12.6" H x 16.7" W x 4.5" D
Weight 22 lbs (with 8 modules)
Environmental
Operating Temp 5 to 40°C (40 to 105°F)
Operating Humidity 10% to 90% non condensing
Important: Module voltage ratings: IHV1 module maximum 250 Vrms CAT II; IHV2 module maximum 600 Vrms CAT II, 300 Vrms CAT III.
Important: Current clamps and voltage probes in various sizes and ranges are available for a wide variety of power applications (selected to match the application).

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Backed by a ValueTronics warranty.
  • Functional verification included before shipment.
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.