HIOKI CT6875 500 A AC/DC Current Sensor

HIOKI CT6875 500 A AC/DC Current Sensor

Regular price $1,914
Sale price $1,914 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

🎓 Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

HIOKI CT6875 500 A AC/DC Current Sensor

Key Features At A Glance

  • AC/DC current sensing across the series, with rated currents from 500 A to 2000 A (model-dependent)
  • Frequency band spanning DC to 2 MHz across the series (±3 dB typical, varies by model)
  • Zero Flux (fluxgate detection) method with newly developed opposed split coil for a broad measurement band
  • High CMRR: 140 dB or greater (50/60 Hz) and 120 dB or greater (100 kHz) for strong noise immunity
  • Basic amplitude accuracy of ±0.04% rdg. ±0.008% f.s. (DC and 45 Hz to 66 Hz)
  • Dedicated ME15W interface; powered from a PW6001/PW3390 analyzer or CT9555/CT9556/CT9557 sensor unit
  • Wide operating temperature range of -40°C to 85°C, 80% RH or less (no condensation)
  • Built for high-current, high-speed EV/HEV inverter and power conversion efficiency measurement
View full details

The CT6875, CT6876, and CT6877 are AC/DC current sensors that pass a measured conductor through their aperture to deliver a proportional voltage output to a host power analyzer. Sensor performance is built on the Zero Flux (fluxgate detection) measurement method: high-frequency current is detected with windings using the CT method, while direct and low-frequency current is detected with fluxgates. A newly developed opposed split coil broadens the measurement band, and strengthened shielding boosts anti-noise performance for high-accuracy current measurement.

These sensors are intended for evaluating the power conversion efficiency of inverters, motors, and batteries, with particular emphasis on measuring the efficiency of increasingly high-current, high-speed EV/HEV inverters. The 5 MS/s, 18-bit sampling of the host PW6001 supports true power analysis of PWM waveforms free of aliasing error, and the improved noise resistance allows accurate measurement of switching current that would otherwise be obscured by noise. The 2000 A CT6877 is also applied to PV and wind-turbine power conditioner (PCS) efficiency measurement, sensing AC current on the power-system side of the conversion stage.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us match the right instrument to your application and ship quickly.

Compare Other Models in This Series

The CT6875, CT6876, and CT6877 form a family of AC/DC current sensors built on Hioki's Zero Flux (fluxgate detection) measurement method. Across the series, rated current spans 500 A, 1000 A, and 2000 A AC/DC, with each model paired to a frequency band suited to its current class. All three use the newly developed opposed split coil winding to broaden the measurement band, while strengthened shielding boosts anti-noise performance.

Every model in the series outputs a voltage proportional to the measured current through the dedicated ME15W connector and draws its power from a PW6001 or PW3390 analyzer, a CT9555/CT9556/CT9557 sensor unit, or an external DC supply. They share a -40°C to 85°C operating range and the same 1-year accuracy guarantee, differing chiefly in current rating, frequency band, output sensitivity, and measurable-conductor diameter.

Each new model below is its own dedicated product page with condition-matched pricing. Select the model whose rated current, frequency band, and measurable-conductor diameter match your measurement, then choose the new listing that fits your sourcing requirements.

The CT6875 is the 500 A AC/DC member of the series and carries the widest frequency band at DC to 2 MHz (±3 dB typical). It outputs 4 mV/A, accepts conductors up to φ36 mm (1.42 in), and allows a maximum input of up to ±1500 Apeak (design value) at 40°C or less for 20 ms or less within the derating range.

The three models differ primarily in rated current and frequency band. The CT6875 measures up to 500 A AC/DC with a DC-to-2 MHz band; the CT6876 measures up to 1000 A AC/DC with a DC-to-1.5 MHz band; and the CT6877 measures up to 2000 A AC/DC with a DC-to-300 kHz band. As rated current rises across the series, the upper frequency limit steps down accordingly.

Physical and output characteristics follow the same pattern. The CT6875 and CT6876 accept conductors up to φ36 mm (1.42 in), while the CT6877 accommodates conductors up to φ80 mm (3.15 in). Output sensitivity is 4 mV/A on the CT6875, 2 mV/A on the CT6876, and 1 mV/A on the CT6877. Each model is also offered in a -01 variant with a 10 m output cable in place of the standard 3 m.

Model Rated Current Frequency Band Conductor Diameter
CT6875 500 A DC to 2 MHz φ36 mm
CT6876 1000 A DC to 1.5 MHz φ36 mm
CT6876 1000 A DC to 1.2 MHz φ36 mm
CT6877 2000 A DC to 300 kHz φ80 mm

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • User Guide
  • Marker bands
  • Operating precautions (0990A907)

Product Core & Specifications

Specification Value
Amplitude & Phase Accuracy (Accuracy guaranteed for 1 year)
DC Amplitude: ±0.04% rdg. ±0.008% f.s.; Phase: —
DC < f < 16 Hz Amplitude: ±0.1% rdg. ±0.02% f.s.; Phase: ±0.1°
16 Hz ≤ f ≤ 45 Hz Amplitude: ±0.05% rdg. ±0.01% f.s.; Phase: ±0.1°
45 Hz < f ≤ 66 Hz Amplitude: ±0.04% rdg. ±0.008% f.s.; Phase: ±0.1°
66 Hz < f ≤ 100 Hz Amplitude: ±0.05% rdg. ±0.01% f.s.; Phase: ±0.1°
100 Hz < f ≤ 500 Hz Amplitude: ±0.1% rdg. ±0.02% f.s.; Phase: ±0.2°
500 Hz < f ≤ 1 kHz Amplitude: ±0.2% rdg. ±0.02% f.s.; Phase: ±0.4°
1 kHz < f ≤ 5 kHz Amplitude: ±0.4% rdg. ±0.02% f.s.; Phase: ±0.5°
5 kHz < f ≤ 10 kHz Amplitude: ±0.4% rdg. ±0.02% f.s.; Phase: ±(0.1 × f kHz)°
10 kHz < f ≤ 50 kHz Amplitude: ±1.5% rdg. ±0.05% f.s.; Phase: ±(0.1 × f kHz)°
50 kHz < f ≤ 100 kHz Amplitude: ±2.5% rdg. ±0.05% f.s.; Phase: ±(0.1 × f kHz)°
100 kHz < f ≤ 1 MHz Amplitude: ±(0.025 × f kHz)% rdg. ±0.05% f.s.; Phase: ±(0.1 × f kHz)°
Frequency band 2 MHz (±3 dB Typical)
General
Rated current 500 A AC/DC
Output voltage (sensitivity) 4 mV/A
Maximum input current Within the derating range. Maximum input of up to ±1500 Apeak (design value) allowed at 40°C or less for 20 ms or less
Output impedance 50 Ω ±10 Ω
Offset voltage ±15 ppm Typical (23°C)
Linearity ±5 ppm Typical (23°C, no input)
Diameter of measurable conductors φ36 mm (1.42 in) or less
Output connector ME15W
Cable length 3 m (9.84 ft)
Temperature and humidity range for guaranteed accuracy 0°C to 40°C (32°F to 104°F), 80% RH or less
Effect of temperature In ranges from -40°C to 0°C (-40°F to 32°F) and 40°C to 85°C (104°F to 185°F): Amplitude sensitivity: ±20 ppm of rdg./°C; Offset voltage: ±5 ppm of f.s./°C
Magnetic susceptibility 10 mA or less (Scaled value, after input of 500 A DC)
Common-mode voltage rejection ratio (CMRR) 140 dB or greater (50 Hz/60 Hz), 120 dB or greater (100 kHz)
Effect of conductor position DC, 50 Hz/60 Hz: ±0.01% rdg. or less (100 A input); 10 kHz: ±0.4% rdg. or less (10 A input); 100 kHz: ±2.5% rdg. or less (10 A input); with a wire diameter of 10 mm
Effect of external magnetic field 20 mA or less (Scaled value, in a DC and 60 Hz magnetic field of 400 A/m)
Operating temperature and humidity range -40°C to 85°C, 80% RH or less (no condensation)
Storage temperature and humidity range -40°C to 85°C, 80% RH or less (no condensation)
Power supply Power supplied from PW6001, PW3390, CT9555, CT9556, CT9557, or external DC power supply
Dimensions Approx. 160 mm (6.30 in) W × 112 mm (4.41 in) H × 50 mm (1.97 in) D
Mass Approx. 0.8 kg (28.2 oz)
Accessories User Guide, marker bands, and operating precautions (0990A907)
Important: Amplitude and phase accuracy are guaranteed over a temperature and humidity range of 0°C to 40°C (32°F to 104°F), 80% RH or less, for input of 110% f.s. or less within the derating range.
Important: This AC/DC current sensor has no internal power source. Power is supplied from a Power Analyzer PW6001 or PW3390, a Sensor Unit CT9555/CT9556/CT9557, or an external DC power supply (CT6877 lists PW6001/PW3390 or CT9555/CT9556/CT9557) — the host instrument is required for operation and is not included.
Important: The sensor output uses an ME15W connector. To interface with a PL23 input, the CT9901 Conversion Cable is required (sold separately); the CT9902 Extension Cable (5 m) extends the output cable, combinable for a maximum additional length of 10 m (32.81 ft).
Important: Maximum input current applies within the derating range only; refer to the frequency-derating curves. For the φ36 mm models, maximum input of up to ±1500 Apeak (CT6875) / ±1800 Apeak (CT6876) is a design value allowed at 40°C or less for 20 ms or less.
Recommended pairing: use with the Hioki Power Analyzer PW6001 or PW3390, the host instruments for which the combined current, power, and phase accuracy figures are specified.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

HIOKI

Condition

Factory New

Manufacturer

HIOKI

Curr_prob_freq

DC to 2 MHz