Features:

LeCroy, Probe, High Voltage Fiber Optic, 150 MHz Bandwidth.  Includes soft-carrying case.

  • 150 MHz bandwidth
  • 35 kV common-mode voltage rating
  • Silicon Carbide Suitable
  • Reduced DUT loading, better pulse response compared to conventional HV differential probes
  • Selectable tips for from +/-1V to +/-40V
View full details

The HVFO108, with 150 MHz of bandwidth, is suitable for both Silicon and Silicon Carbide designs. It is designed to measure small signals floating on an HV bus and delivers excellent performance, has high CMRR, and provides optical isolation to reduce DUT loading.

The HVFO108 faithfully reproduces upper-side gate drive signals without loading and distortion, allowing a clear view of the Miller effect. Any conventional HV differential probe with high tip capacitance in parallel with CGE or CGS, and/or high impedance and large loop inductance in series with the gate drive impedance will at best load the gate drive signal or pick up interference and at worst cause circuit malfunction. The HVFO108 performs much better for these measurements.

The HVFO108 measures only the low voltage sensor voltage across its high impedance input leads. Total load on the device under test (DUT) is very small. Furthermore, the low lead loop inductance, >100dB CMRR, and low attenuation provide superior signal fidelity, noise and rejection.

AC and DC sensor signals floating at a high voltage or in the presence of EMC disturbance signals can be acquired with high signal fidelity and correctly correlated to in-circuit and control activities.

Optical isolation between the probe tip and the oscilloscope input reduces adverse loading of the DUT, provides faithful pulse response, and increases confidence in the measurement. Safety against dangerous high voltage levels can be ensured and unsafe "floating" of the oscilloscope can be avoided.

High CMRR (140 dB) provides more accurate representation of the measured signal despite the presence of high dV/dt or dA/dt events elsewhere in the circuit. The test lead is optimized to limit loop inductance and radiated pickup. Tip attenuations are optimized for a wide range of signal amplitudes.

Accessories:

  • High Voltage Fiber Optic Probe
  • 150 MHz Bandwidth
  • Includes soft-carrying case
  • Qty. 1 Amplifier/Modulating Transmitter
  • Qty. 1 Demodulating Receiver
  • Qty. 1 1m Fiber Optic Cable
  • Qty. 1 USB Charging Cable
  • Qty. 1 Micro-gripper set

Model No

HVFO108

Condition

New

Manufacturer

Teledyne LeCroy

Frequency

150 MHz

Voltage

35 kV