Teledyne LeCroy CP150 150 A 10 MHz Current Probe (Pre-Owned)

Teledyne LeCroy CP150 150 A 10 MHz Current Probe (Pre-Owned)

🎓 Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Teledyne LeCroy CP150 150 A 10 MHz Current Probe (Pre-Owned)

Key Features At A Glance

  • Maximum insulated wire voltage: 300 V CAT I, 600 V CAT II, 300 V CAT III across the series
  • ProBus active probe interface with automatic scaling in A/div for integrated oscilloscope operation
  • AC, DC, and impulse current measurement via Hall-effect and transformer technology — no circuit breaking or shunt insertion
  • Bandwidths up to 100 MHz, peak currents up to 700 A, and sensitivities to 1 mA/div across the model range
  • Autozero and degauss functions built into the oscilloscope's user interface
  • High-sensitivity models offering 1 mA/div for precise low-current measurements
  • Powered through the ProBus connection — no additional hardware required
  • Series spans 30 to 500 Arms continuous current, 50 to 700 Apeak, and bandwidths from 2 MHz to 100 MHz
  • AC, DC, and GND coupling with 1% low-frequency accuracy
  • Compatible with Teledyne LeCroy oscilloscopes equipped with a ProBus interface
View full details

Teledyne LeCroy current probes measure current without requiring the breaking of a circuit or the insertion of a shunt. Based on a combination of Hall effect and transformer technology, they are designed for making accurate AC, DC, and impulse current measurements, and connect to the oscilloscope through the Teledyne LeCroy ProBus interface for automatic scaling in A/div.

A current probe clamps around a conductor to measure the current flowing through it and reproduces that current as a waveform on an oscilloscope, letting an engineer observe amplitude, timing, and shape without interrupting the circuit under test. Teledyne LeCroy current probes are available in a variety of models for a wide range of applications and are often used in the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.

ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received — so you get the right instrument in the condition you expect, backed by people who know the equipment.

Brand Heritage

LeCroy Corporation was acquired by Teledyne Technologies in 2012, after which the test and measurement business has operated under the Teledyne LeCroy name. LeCroy Corporation was founded in 1964.

Compare Other Models in This Series

Teledyne LeCroy current probes are offered in a variety of models spanning a wide range of applications. The full range includes models with bandwidths up to 100 MHz, peak currents up to 700 A, and sensitivities to 1 mA/div, all sharing the ProBus active probe interface and the same Hall-effect and transformer measurement approach.

Each model in the family is matched to a different combination of current capacity and bandwidth, from lower-current high-bandwidth probes for fast signals to high-current probes for power applications. The comparison table below lists the per-model electrical and general characteristics so you can match a probe to your current range, bandwidth, and sensitivity requirements.

Each pre-owned model linked below is its own dedicated product page with condition-matched pricing. Select the specific model that fits your measurement requirements to see its availability and price.

The models differ primarily in maximum continuous input current (30 Arms, 150 Arms, and 500 Arms), bandwidth (from 2 MHz up to 100 MHz), peak current (50 Apeak, 500 Apeak, and 700 Apeak), and minimum sensitivity (10 mA/div, 100 mA/div, or 1 mA/div on the high-sensitivity models). Rise time and cable length also vary by model.

The CP030A and CP031A add 1 mA/div minimum sensitivity and a 1 V/A output range alongside the standard 0.1 V/A, with an associated offset range, where the base CP030 and CP031 do not. Refer to the comparison table that follows for each model's exact values, including the long-cable CP030-3M and CP150-6M variants noted as not EMC compliant.

Model Max Continuous Current Bandwidth Max Peak Current
CP150 150 Arms 10 MHz 500 Apeak
CP030 30 Arms 50 MHz 50 Apeak
CP030 30 Arms 10 MHz 50 Apeak
CP030A 30 Arms 50 MHz 50 Apeak

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
Electrical Characteristics (Guaranteed at 23 °C ±3 °C)
Max. Continuous Input Current 150 Arms
Bandwidth 10 MHz
Rise Time (typical) ≤ 35 ns
Max. Peak Current 300 Apeak (non-continuous); 500 Apeak ≤ 30 μs
Output Voltage 0.01 V/A
Minimum Sensitivity 100 mA/div
Low-Frequency Accuracy 1%
AC Noise at 20 MHz BWL ≤ 6.0 mA
Coupling AC, DC, GND
General Characteristics
Cable Length 2 m
Weight 500 g
Max. Conductor Size (Diameter) 20 mm
Interface ProBus, 1 MΩ only
Usage Environment Indoor
Operating Temperature 0 ˚C to 40 ˚C
Max. Relative Humidity 80%
Max. Altitude 2000 m
Maximum Insulated Wire Voltage 600 V CAT II, 300 V CAT III
Important: Note: the 3 m CP030-3M and 6 m CP150-6M long-cable versions are not EMC compliant.
Important: Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus connection and require a compatible Teledyne LeCroy oscilloscope with a ProBus interface; they are not standalone instruments.
Important: CP03x, CP150, and CP500 probes (and long-cable versions of these) are compatible with any Teledyne LeCroy oscilloscope with a ProBus interface running firmware version 4.3.1.1 or greater.
Important: Teledyne LeCroy current probes are powered through the ProBus connection and require no additional hardware, but they must be used with a Teledyne LeCroy oscilloscope that has a ProBus interface: CP03x, CP150, and CP500 probes (and their long-cable versions) require firmware version 4.3.1.1 or greater; CP03xA probes require X-Stream firmware version 7.8.x.x or later (compatible families include WaveSurfer Xs-A, MXs/MXs-A/MXs-B and 10, HDO4000/6000/8000/9000, MDA800, HRO/WaveRunner 6 Zi, WaveRunner 8000 and Xi/MXi families, WavePro/SDA/DDA 7 Zi, WaveMaster/SDA/DDA 8 Zi, and LabMaster 9 Zi-A).
Important: CP03xA probes (CP030A and CP031A) are compatible with most Teledyne LeCroy oscilloscopes with a ProBus interface running X-Stream firmware version 7.8.x.x or later; WavePro 7000/7000A and WaveSurfer Xs series have additional Windows XP Professional / firmware upgrade requirements (contact your local service center regarding upgrades).
Important: The DCS025 deskew calibration source provides time-aligned voltage and current signals for precise probe deskew; most voltage probes along with the 30, 150 and 500 A current probes are compatible with the DCS025. It is ordered separately and is not included with the probes.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Teledyne

Condition

Pre-Owned

Manufacturer

Teledyne LeCroy

Curr_prob_freq

10 MHz

AP033 Teledyne LeCroy Differential Probe Used

AP033

ZD1000 Teledyne LeCroy Differential Probe Used

ZD1000

ZS1500 Teledyne LeCroy Active Probe Used

ZS1500

AP031 Teledyne LeCroy Differential Probe Used

AP031

PP026 Teledyne LeCroy Voltage Probe Used

PP026

PP066 Teledyne LeCroy Voltage Probe Used

PP066