Skip to content

The A6312 is a DC-coupled current probe rated for DC to 100 MHz bandwidth, designed for use with the AM 503, AM 503A, AM 503B, and AM 5030 current probe amplifiers. Its split-core construction permits easy connection to the circuit under test, and it may be ordered either separately as the A6312 or as Option 05 to the AM 503S current measurement system.
A current probe clamps around a conductor to measure the current flowing through it without breaking the circuit, presenting the result as a voltage waveform for display on an oscilloscope. The combination of an A6312, an AM 503B, and a TM502A forms a current-measurement tool that can display currents up to 20 amps DC + peak AC and 50 amps peak pulse on any oscilloscope. Because the probe is DC-coupled, it measures both the DC and AC components of a current simultaneously.
ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Pre-owned instruments are inspected and functionally verified in-house before they ship, while new units arrive and leave factory-sealed exactly as received.
Tektronix was founded in 1946 and has operated under the Tektronix name ever since. The company was acquired by Danaher Corporation in 2007 and became part of Fortive Corporation when Fortive was spun off from Danaher in 2016.
| Specification | Value |
|---|---|
| Standard Specifications (A6312/AM 503B/TM502A) | |
| Bandwidth | DC to 100 MHz |
| Maximum DC + Peak AC Current | 20 Amps |
| Maximum Peak Pulse Current | 50 Amps |
| Minimum Sensitivity | 1 mA/div |
| DC Accuracy | ±3% (±1.5% typical) |
| Maximum Barewire Voltage | 300 Volts (Category I) |
| Typical Characteristics | |
| Insertion Impedance | 0.1 Ohms at 1 MHz; 0.2 Ohms at 50 MHz; 1.0 Ohm at 100 MHz |
| Propagation Delay | 17 ns |
| Maximum Conductor Diameter | 3.8 mm (0.15 in.) |
| Electrostatic Immunity (per IEC 801-2) | >8 kV |
| Amp * Sec Product | 100 x 10–6 Amp * sec |
| Risetime | ≤3.5 ns |
| Physical Characteristics | |
| Probe Weight | 0.25 kg (0.56 lbs.) |
| Cable Length | 2 m (6.6 ft.) |
| Power Requirements | |
| Power Source | Powered by the AM 503B/TM502A |
| Safety Certifications | |
| UL | UL 3111-1 |
| CSA | CSA 1010.1 |
| IEC | IEC 1010-1, 1010-2-032 |
| System Specifications | |
| Bandwidth (A6312/AM 503B) | DC to 100 MHz |
| Bandwidth (A6312/AM 5030) | DC to 100 MHz |
| Bandwidth (A6312/AM 503A) | DC to 80 MHz |
| Bandwidth (A6312/AM 503) | DC to 100 MHz |
| Risetime, 10% to 90% (A6312/AM 503B) | ≤3.5 ns |
| Risetime, 10% to 90% (A6312/AM 5030) | ≤3.5 ns |
| Risetime, 10% to 90% (A6312/AM 503A) | ≤4.4 ns |
| Risetime, 10% to 90% (A6312/AM 503) | ≤3.5 ns (requires adjustment of R364 HFComp in amplifier) |
| Aberrations, typical (all combinations) | 7% p-p |
| DC Gain Accuracy (A6312/AM 503B) | ≤3% (<1.5% typical) |
| DC Gain Accuracy (A6312/AM 5030) | ≤3% |
| DC Gain Accuracy (A6312/AM 503A) | ≤3% |
| DC Gain Accuracy (A6312/AM 503) | ≤3% |
| Noise, RMS, typical (all combinations) | ≤250 µA |
Important: Maximum barewire voltage: 300 V (Category I).
Important: The A6312 is powered by the AM 503B/TM502A; the listed performance specifications apply to this combination of products. A current probe amplifier (AM 503, AM 503A, AM 503B, or AM 5030) and a TM502A mainframe are required to operate the probe and are not included with the A6312.
Important: For the A6312/AM 503 combination, the specified risetime and aberrations require adjustment of R364 (HFComp) in the amplifier.
This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Pre-Owned
Manufacturer
Tektronix
Curr_prob_freq
100 MHz
Request A Quote