Key Features At A Glance

  • Handheld µOTDR platform with 2 cm sampling resolution and event dead zones as short as 0.8 m for short-fiber and intra-building analysis
  • Dynamic range up to 38 dB on top-tier modules — capable of testing fiber spans up to approximately 175 km per the datasheet
  • Tri-wavelength configurations available for combined installation (1310/1550 nm) and maintenance (filtered 1625 nm or 1650 nm) testing
  • Integrated 10 m launch fiber built into the MU909014/15 series — verifies initial connections without external patchcords
  • Fiber Visualizer mode automatically selects test parameters and presents a graphical event summary for simplified operation
  • Built-in PON Power Meter, Loss Test Set, and Light Source functions available on C6/A6 modules for complete FTTx workflows
  • Bluetooth, WLAN, and Ethernet connectivity via USB dongle for file sharing and remote GUI control from a browser
  • 4.3-inch TFT color display with NiMH battery operation providing approximately 8 hours of typical runtime per the datasheet
Share on
View full details

The Anritsu MT9090A Network Master is a handheld µOTDR platform designed for installation and maintenance of optical fiber networks. The system consists of the MT9090A mainframe paired with an MU909014 or MU909015 µOTDR Module, with module options spanning single-wavelength maintenance configurations, dual-wavelength installation configurations, and tri-wavelength configurations covering both installation and maintenance workflows. The complete unit measures 190 × 96 × 48 mm and weighs under 700 g including the mainframe, module, and standard battery.

According to the datasheet, the MT9090A is positioned for fiber network applications spanning premise and access through metro and core, including PON-based FTTx networks with splitter ratios up to 1 × 64. The platform supports central office, FTTx, and intra-building cable evaluation through its 0.8 m event dead zones, and long-haul fiber characterization through dynamic range options up to 38 dB. The Fiber Visualizer mode is designed to simplify the testing workflow so that operators without deep OTDR expertise can obtain a graphical summary of the fiber under test within seconds.

ValueTronics International stocks and supports the Network Master MT9090A platform and its MU909014/15 module configurations from our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every {{CONDITION}} unit is inspected and functionally evaluated by our technical team before it ships, so the optical performance behind a fiber commissioning or maintenance program is verified rather than inferred. As a multi-brand distributor with over three decades in optical and RF test, ValueTronics handles configuration confirmation, accessory verification, and connector-adapter matching directly — rather than passing those steps through a drop-ship channel.

Brand Heritage

Anritsu Corporation is a Japanese precision measurement company with roots extending to 1895. The optical test capabilities now branded under Anritsu were significantly expanded through the acquisition of NetTest's optical test product line, which the brochure references in describing over 50 years of combined OTDR design heritage. Anritsu remains an independent, publicly traded T&M manufacturer headquartered in Atsugi, Japan.

Compare Other Models in This Series

The MU909014/15 µOTDR Module family spans three commercial tiers built around the common MT9090A mainframe. Maintenance-only modules (MU909014A1, MU909015A6) provide single-wavelength testing at 1625 nm or 1650 nm for in-service fiber work. General-purpose installation modules (MU909014B/B1, MU909015B/B1) provide dual 1310/1550 nm OTDR testing. Combined installation-and-maintenance modules (MU909014C/C6, MU909015C/C6) provide tri-wavelength coverage in a single instrument.

Within each tier, the '14' versus '15' designation distinguishes dynamic range class: the MU909014 modules are 30 dB-class instruments (typically 32.5 dB at 20 µs), while the MU909015 modules are 35 dB-class instruments (35–38 dB at 20 µs depending on wavelength). The 'C6' and 'A6' suffixes indicate inclusion of the integrated PON Power Meter, Power Meter, Light Source, and Loss Test Set FTTx workflow functions.

Each pre-owned MT9090A configuration linked below is its own listing with condition-matched pricing. Module variants differ in wavelength coverage, dynamic range class, included FTTx workflow functions, and UPC versus APC connector interface — confirm the option suffix on the specific listing matches your fiber plant before ordering.

The principal differences across the family are wavelength coverage, dynamic range, and integrated workflow functions. Wavelength configurations include single-wavelength maintenance (1625 nm or 1650 nm), dual-wavelength installation (1310/1550 nm), tri-wavelength installation-and-maintenance (1310/1550 nm plus filtered 1625 nm or 1650 nm), and the 1310/1490/1550 nm installation configuration available on the -059 and -069 option codes. Dynamic range at 20 µs pulse width varies from 32.5 dB (14-series, 30 dB class) up to 38 dB (15-series C/C6 modules at 1310 nm).

Dead zone and sampling resolution also differ by tier: the C/C6 and A6 modules provide ≤0.8 m Fresnel dead zone (typical) and 2 cm sampling resolution with up to 250,001 sampling points, while the A1/B/B1 modules provide ≤1 m Fresnel dead zone and 5 cm sampling resolution with up to 125,001 sampling points. Integrated FTTx workflow functions — PON Power Meter, Loss Test Set, Light Source, DCFL mode — are available on the C6 and A6 module variants and absent on the base C, B/B1, and A1 variants. The comparison table that follows summarizes these distinctions across the available models.

Model Wavelengths Dynamic Range (20 µs) Dead Zone (Fresnel)
MT9090A
MU909014A1-053 1625 nm 32.5 dB ≤1 m
MU909014A1-063 1625 nm 32.5 dB ≤1 m
MU909014A1-054 1650 nm 32.5 dB ≤1 m

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • G0202A Replacement NiMH Battery Pack (two supplied with MT9090A + MT9090A-001 order)
  • G0203A Replacement AC Charger/Adapter
  • B0601B Standard Soft Case
  • Z1023A Replacement Strap
  • B0663A Protector

Product Core & Specifications

Specification Value
Dimensions and Mass 190 (W) × 96 (H) × 48 (D) mm (7.5" × 3.8" × 1.9") (including Mainframe and Module); <700 g (1.54 lbs.) (including Mainframe, Module and Standard battery)
Display 4.3-inch TFT Color LCD (480 × 272 pixels, Transmissive)
Interface USB 1.1, Type A × 1 (memory), Type B × 1 (USB mass storage)
Important: Maximum safe optical input levels and laser safety classification differ by module — the C/C6 modules are rated IEC 60825-1:2007 Class 1M, while certain A1/B1 configurations with the visible laser diode option are rated Class 3R. Confirm the specific module variant against your safety program before deployment.Important: Bluetooth, WLAN and Ethernet connectivity features require a USB Ethernet converter, USB WLAN dongle, or USB Bluetooth dongle (not part of the standard mainframe accessory set per the datasheet).Important: Connector adapters (FC, SC, DIN, FC-APC, SC-APC) are included at no charge but must be added as a separate line item when ordering, per the Ordering Information.Important: For the 1650 nm models, a 1490/1550 nm cut filter is included on the 1650 nm port; dynamic range specifications assume the in-service signal at 1310/1550 nm is ≤ –20 dBm CW.Important: Visible Fault Locator (VLD) is a factory-installed option available only on MU909014A1, MU909014B1 and MU909015B1 models; not available on all modules. See Ordering Information for installation restrictions per model.Recommended pairing: when ordering an APC-connectorized module (option suffixes -063, -064, -066, -067, -068, -069), specify the matching FC-APC, SC-APC, or compatible adapter listed in the datasheet's connector adapter selection table. UPC-connector modules (-053, -054, -056, -057, -058, -059) pair with FC, SC, or DIN 47256 adapters.

About this used unit

  • Warranty included on every pre-owned MT9090A unit shipped from our Elgin facility.
  • Functional verification performed by ValueTronics technicians prior to shipment.
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.