Applications:
The Chroma GUARDIAN 500VA PLUS HiPot Analyzer is designed for applications requiring a 500VA output transformer capacity with 100mA AC current output. The analyzer has both HiPot test and analysis modes making the unit flexible for both production and R&D applications. The tests of AC/DC/IR can be programmed to 5000 VAC, 6000 VDC and 5000 VDC for IR. The full floating output complies with the EN50191 requirements for operator safety.
The Guardian 500VA Plus features a large LCD screen for programming and measurement. Ground Fault Interruption and Floating Output features can also be used for operator protection. The HiPot tester is equipped with an output to monitor the arc signal with an oscilloscope.
The Guardian 500VA Plus is equipped with a new Function called High Frequency Contact Check (HFCC) besides the Open Short Check (OSC). These two features are designed to determine if a connection to the product has been made during testing or prior to testing. HFCC operates during testing and OSC is used as a step prior to HiPot or IR testing. OSC operates by measuring the capacitive load (Cx) of the DUT from tens to thousands pF and looking for a change in capacitance from the nominal capacitance of the DUT to determine connection. HFCC (High Frequency Contact Check) is a new measurement technology for contact check. HFCC is able to be performed during the HiPot test using a high frequency, around 1 MHz, for improved test time on the production line.
Model No
GUARDIAN
Condition
New
Manufacturer
Chroma