Skip to content
Complete Dielectric Testing Solution
The Chroma 19050 Series electrical safety testers are advanced digital hipot testers with load and line regulations that help ensure measurement integrity. The Multi-step capability allows users to perform multiple tests in sequence, such as AC hipot followed by IR.
The 19050 Series Hipot Testers have 3 models available for selection: the 19052, 19053, and 19054. The 19052 includes AC/DC hipot testing and IR (Insulation Resistance) measurement while the 19053 provides 8 scan channels for AC/DC hipot testing and IR measurement. The 19054 provides 4 scan channels for AC/DC hipot testing and IR measurement in a single compact unit.
The 19070 Series has 2 models available for selection: the 19071 and the 19073. The 19071 is for AC Hipot testing while the 19073 combines both AC/DC hipot with IR measurement into a single compact unit.
Open Short Check (OSC)
The OSC function is used to check whether the connection is an open circuit between the instrument and the DUT or if there is a breakdown inside the DUT before testing for electrical safety.
Flashover (ARC) Detection
The 19070 and 19050 series are sensitive enough to monitor for current spikes even if they do not exceed the maximum trip current level.
Ground Continuity Check (GC)
All of the 19070 and 19050 series testers have a ground continuity check feature to determine if the resistance between the ground pin of the power cord and any exposed metal on the product is less than 1Ω.
Ground Fault Interrupt (GFI)
GFI is required by the National Electrical Code in wet locations. Such devices automatically interrupt power when a ground current > 0.5mA exists for more than a few milli-seconds to protect users.
Quick Discharge
For DC hipot and IR tests, the DUT is discharged back through the HV transformer attaining a rapid and safe discharge.
Model No
19052
Condition
New
Manufacturer
Chroma