An LCR meter measures the inductance (L), capacitance (C), and resistance (R) of passive components by applying a known AC test signal and analyzing the resulting impedance. The ZM2371, ZM2372, and ZM2376 are bench LCR meters that report both primary parameters — |Z|, |Y|, L, C, R, and G — and secondary parameters including Q, D, θ, X, B, Rs, Rp, Lp, and Rdc, with parallel, series, or automatic equivalent-circuit selection.
Across the series, primary and secondary parameters can be selected automatically, and each instrument displays the voltage applied to the device under test alongside the current flowing through it. A built-in comparator evaluates measurements against multiple limit conditions — up to 32 steps for total comparison — and drives an optically isolated handler interface whose BIN outputs support sorting of components in automated handling systems.
ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments we list are on hand and ready to ship.
The ZM2371, ZM2372, and ZM2376 form a family of LCR meters that share a common measurement architecture — eight measurement ranges from 100 mΩ to 1 MΩ, 0.08% basic accuracy, constant-voltage/constant-current drive, and a full set of correction functions — while differing primarily in maximum measurement frequency and comparator bin capacity.
All three models present the same primary and secondary parameters and the same standard remote-control interfaces, so the choice among them centers on the measurement frequency range and the sorting capacity an application requires.
Each model below links to its own dedicated product page with new-condition pricing. Select the specific model that matches your measurement frequency and sorting requirements to see its current availability and price.
The ZM2376 extends the measurement frequency to 5.5 MHz — the widest in this family — offers a wider internal DC bias setting range, and is supplied with IVI drivers for instrument-control environments.
The most significant difference across the family is maximum measurement frequency: the ZM2371 and ZM2372 cover settings up to 100 kHz, while the ZM2376 extends to 5.5 MHz. The ZM2376 also offers a wider internal DC bias setting range and is supplied with IVI drivers, whereas the ZM2371 and ZM2372 include a LabVIEW driver.
The models also differ in comparator bin capacity and in physical depth and weight. Refer to the comparison table below for the exact figures per model.
| Model | Max. Measurement Frequency | Frequency Resolution | Max. Internal DC Bias |
|---|---|---|---|
| ZM2371 | 100 kHz | 5 digits | +2.50 V |
| ZM2372 | 100 kHz | 5 digits | +2.50 V |
| ZM2376 | 5.5 MHz | 6 digits | +5 V |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Measurement Parameters | |
| Primary parameters | |Z|, |Y|, L, C, R, G (for equivalent circuit of L, C, R: Parallel / Series / Auto Selection selectable) |
| Secondary parameters | Q, D, θ, X, B, Rs, Rp, G, Lp, Rdc |
| Auto parameter selection | Primary parameters (including equivalent circuit) and secondary parameters can be selected automatically |
| Measured Value Display Range | |
| |Z|, R (Rs, Rp, Rdc), X | 0Ω, ±(0.001 mΩ to 999.999 MΩ) |
| |Y|, G, B | 0S, ±(0.01 nS to 9.99999 kS) |
| C (Cp, Cs) | 0F, ±(0.00001 pF to 999.999 kF) |
| L (Ls, Lp) | 0H, ±(0.001 nH to 99.9999 GH) |
| Q, D | 0, ±(0.00001 to 99999.9) |
| θ | ±180.000 deg |
| Measurement Conditions | |
| Measurement frequency | Setting range: 1 mHz to 100 kHz, Resolution 5 digits (1 mHz when < 10 Hz); Accuracy: ±0.01% |
| Measurement signal level | 10 mVrms to 5.00 Vrms, Resolution 3 digits (1 mVrms when < 100 mVrms), RMS values at open output; Accuracy: ±(10% + 5 mVrms) |
| Constant voltage / Constant current mode (ALC) | Constant voltage / Constant current / Disabled. Voltage setting range: 10 mVrms to 5.00 Vrms, Resolution 3 digits (<100 mVrms: 1 mVrms); Current setting range: 1 µArms to 200 mArms, Resolution 3 digits (<10 µArms: 0.1 µArms) |
| Output impedance | 5Ω / 25Ω / 100Ω, automatically selected according to the measurement range |
| Internal DC bias | Setting range: 0 V to +2.50 V, Resolution: 0.01 V, Accuracy: ±(5% + 3 mV). Can be turned on/off at open output |
| Trigger source | INT (internal automatic continuous), MAN (manual), EXT (handler interface), BUS (remote control) |
| Trigger delay time | Setting range: 0.000 s to 999.999 s, Resolution: 0.001 s (time after trigger input until start of signal acquisition) |
| Triggered drive | Selectable: Drive only at measurement / Continuous drive |
| Measurement speed | RAPid / FAST / MEDium / SLOW / VerySLOw |
| Measurement Range | |
| Ranges | 8 ranges (1 MΩ, 100 kΩ, 10 kΩ, 1 kΩ, 100 Ω, 10 Ω, 1 Ω, 100 mΩ) |
| Range selection | Auto / Manual |
| Measurement Accuracy | |
| Basic accuracy | 0.08% (refer to appendix) |
| Other Measurement Functions | |
| Correction function | Open, Short, Load and Cable Length |
| Contact check | Detects a contact failure at four contact points; additional time 4 ms (reference) |
| Averaging | 1 to 256 times |
| Deviation measurement | Primary/secondary parameters: deviation and deviation % from reference value can be displayed |
| Comparator | Primary parameters: Max. 9 bins; Secondary parameters: upper limit and lower limit comparison; original measured value / deviation / deviation % can be sorted |
| Handler interface | All I/O signals are optically isolated (withstand voltage ±42 V). Input: Trigger, Key lock, Settings/correction value memory designation. Output: BIN1 to BIN11, NC/BIN12, PHI/BIN13, PLO/BIN14, OUT OF BINS, S-NG, ERR, INDEX, EOM |
| Multi-measurement | Execute measurement and limit comparison under multiple conditions for the total comparison; maximum number of steps: 32 |
| Monitor display | Voltage value applied to the DUT and current value flowing in the DUT |
| Remote Control Interfaces | |
| USB | USBTMC, USB1.1 Full-speed |
| RS-232 | Data rate: 4800 bps to 230400 bps |
| GPIB | Conforms to IEEE 488.1 and IEEE 488.2 Standards |
| LAN (optional) | 10BASE-T, 100BASE-TX |
| General Specifications | |
| Power supply | AC 100 V to 230 V ±10% (but 250 V or less); Frequency 50/60 Hz ±2 Hz; Overvoltage category II; Power consumption: 70 VA or less |
| Operating environment | Temperature 0 to +40 °C; Humidity 5 to 85% RH (absolute humidity 1 to 25 g/m³, non-condensing) |
| Storage environment | Temperature -10 to +50 °C; Humidity 5 to 95% RH (absolute humidity 1 to 29 g/m³, non-condensing) |
| Pollution degree | Pollution degree 2 (indoor use) |
| Settings/correction value memory | 32 sets; settings and correction values can be saved and restored individually or together |
| Resume | Last setting and correction value are restored at power-on |
| External dimensions | 260 (W) × 88 (H) × 220 (D) mm (not including protuberances) |
| Weight (without accessories) | Approx. 2.0 kg |
Important: Specified measurement accuracy assumes a warm-up of 30 minutes or more, open and short zero correction, cable-length correction per the connection cable length, and a one-year calibration cycle.
Important: The standard supplied accessories (power cord set, instruction manual, CD-ROM/drivers) do not include a measurement fixture or test leads. A connection cable/fixture appropriate to the DUT is required to perform measurements; the datasheet's cable-length correction supports cable lengths of 0 m, 1 m, 2 m and 4 m.
Important: The LAN interface (10BASE-T / 100BASE-TX) is an option and is not fitted on the standard model.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.