Skip to product information
1 of 1
Select Options

Agilent E4418B EPM Series Single-Channel Power Meter (with Power Sensor Cable) (Pre-Owned)

Agilent E4418B EPM Series Single-Channel Power Meter (with Power Sensor Cable) (Pre-Owned)

Regular price $895
Sale price $895 Regular price $0
In Stock
Shipping calculated at checkout.
Calibrations
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent E4418B EPM Series Single-Channel Power Meter (with Power Sensor Cable) (Pre-Owned)

Key Features At A Glance

  • Available as single-channel (E4418B) or dual-channel (E4419B) EPM Series average power meter
  • Frequency coverage from 9 kHz to 110 GHz, sensor dependent across the compatible sensor set
  • Power measurement from -70 dBm to +44 dBm (100 pW to 25 W), sensor dependent
  • Up to 90 dB single-sensor dynamic range with E-Series power sensors
  • GPIB (IEEE 488.2) and RS-232/422 serial interfaces standard for automated measurement systems
  • Compatible with Agilent E4410/E9300 E-Series, 8480 Series and N8480 Series average power sensors
  • Internal 50 MHz power reference, 1.00 mW factory-set to ±0.4% traceable to NPL (UK)
  • Averaging selectable from 1 to 1024 readings for noise reduction
Select Options
View full details

The Agilent E4418B and E4419B are EPM Series power meters for measuring average RF and microwave power. The E4418B is a single-channel instrument and the E4419B is a dual-channel instrument, and both operate with Agilent E-Series and 8480 Series average power sensors over power and frequency ranges that depend on the sensor selected. Together a meter and a compatible sensor form a calibrated average-power measurement system, with the meter automatically reading the calibration-factor data stored in the sensor and applying it to the measurement.

Application coverage spans continuous-wave (CW) and modulated signals, including wireless-standard formats such as GSM, EDGE, NADC, IDEN, cdmaOne, cdma2000, W-CDMA, Bluetooth, 802.11a/b/g, HiperLan2 and WiMAX, as well as pulse and averaged radar and navigation signals, AM/FM-profiled and mobile-radio measurements, and metrology-lab work. The sensor technology is matched to the signal type, with thermocouple sensors, diode sensors, extended-range compensated diode sensors and two-path diode-stack sensors each addressing specific measurement scenarios.

ValueTronics stocks and holds its own inventory in a 20,000 square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, which lets us ship EPM Series meters and matched sensors quickly from our own shelves. Every used unit we sell is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

This product line carries the Agilent Technologies name. Agilent was established in 1999 when Hewlett-Packard spun out its test-and-measurement business as a separate company, and in 2014 that electronic-measurement business was renamed Keysight Technologies.

Compare Other Models in This Series

The EPM Series is built around two power meters that share a common measurement architecture and sensor compatibility: the single-channel E4418B and the dual-channel E4419B. Both read calibration-factor data directly from Agilent E-Series and 8480 Series average power sensors and cover the same sensor-dependent frequency and power ranges, so the choice between them is driven primarily by how many measurement channels the application requires.

Because the two meters use the same internal power reference, the same averaging and resolution settings and the same SCPI-based remote interfaces, a measurement workflow developed on one transfers directly to the other, with the dual-channel model adding simultaneous two-channel display and ratio/difference measurements.

Each pre-owned model below is listed as its own dedicated product page with condition-matched pricing. Select the channel configuration that fits your bench, then choose the pre-owned unit that matches your budget and availability requirements.

The principal difference between the two models is channel count: the E4418B measures a single channel, while the E4419B measures two channels and can simultaneously display combinations such as A, B, A/B, B/A, A-B and B-A. The E4419B also provides dedicated channel-A and channel-B recorder outputs on the rear panel.

Remote-programming compatibility differs as well: the E4418B is 436A and 437B code compatible, while the E4419B is 438A code compatible, with both using SCPI as the standard command set. Measurement speed also reflects the channel count, with the single-channel E4418B reaching a typical maximum of 200 readings/second in Fast mode and the dual-channel E4419B reaching approximately 100 readings/second with both channels in Fast mode. The comparison table below summarizes these per-model differences.

Model Channels Max Measurement Speed GPIB Code Compatibility
E4418B 1 200 readings/second (Fast mode) 436A/437B
E4419B 2 100 readings/second (both channels Fast mode) 438A
E4419B 2 100 readings/second (both channels Fast mode) 438A

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • One 1.5-meter (5-ft) power sensor cable
  • One 2.4-meter (7.5-ft) power cord (power plug matches destination requirements)
  • Hard copy English language User's Guide
  • CD version of the English and localized User's Guide and Programming Guide

Product Core & Specifications

Specification Value
Frequency and Power
Frequency range 9 kHz to 110 GHz, sensor dependent
Power range –70 dBm to +44 dBm (100 pW to 25 W), sensor dependent
Single sensor dynamic range 90 dB maximum (E-Series sensors); 50 dB maximum (8480 Series sensors); 55 dB maximum (N8480 Series sensors)
Display units, absolute Watts or dBm
Display units, relative Percent or dB
Accuracy
Absolute ±0.02 dB (log) or ±0.5% (linear)
Relative accuracy ±0.04 dB (log) or ±1.0% (linear)
Measurement noise calculation (<45 pW x 2.75) = <121 pW
Resolution
Display resolution Selectable resolution of 1.0, 0.1, 0.01, and 0.001 dB in Log mode, or 1 to 4 digits in linear mode
Default resolution 0.01 dB in log mode, 3 digits in linear mode
Power Reference
Power output 1.00 mW (0.0 dBm)
Factory set ±0.4% traceable to the National Physical Laboratory (NPL), UK
Accuracy (for two years) ±0.5% (23 ± 3 °C); ±0.6% (25 ± 10 °C); ±0.9% (0 to 55 °C)
Frequency 50 MHz nominal
SWR 1.06 maximum (1.08 maximum for Option 003)
Connector type Type-N (f), 50 Ω
Measurement Speed (over GPIB, typical maximum)
E4418B – Normal 20 readings/second
E4418B – x2 40 readings/second
E4418B – Fast 200 readings/second
E4419B – both channels in Fast mode 100 readings/second (typical maximum)
Fast mode For E-Series sensors only; maximum measurement speed obtained using binary output and free run trigger mode
Power Meter Functions
Cal / reference cal factor Settable from 1% to 150%, in 0.1% increments
Frequency entry range 1 kHz to 999.9 GHz, settable in 1-kHz steps
Cal factor 1% to 150%, in increments of 0.1%
Offset –100 dB to +100 dB, settable in 0.001-dB increments
Save/recall Store up to 10 instrument states
Filter (averaging) Selectable from 1 to 1024; auto-averaging provides automatic noise compensation
Effects of averaging on noise Averaging over 1 to 1024 readings is available for reducing noise
Duty cycle 0.001% to 99.999%, in increments of 0.001%
Limits High and low limits settable in the range –150 dBm to +230 dBm, in 0.001-dBm increments
Rear Panel Connectors
Recorder outputs Analog 0 to 1-Volt, 1-kΩ output impedance, BNC connector (E4419B recorder outputs are dedicated to channel A and channel B)
Remote input/output RJ-45 series shielded modular jack assembly connector; TTL Output: high = 4.8 V max, low = 0.2 V max; TTL Input: high = 3.5 V min, 5 V max, low = 1 V max, –0.3 V min
GPIB Allows communication with an external controller
RS-232/422 Male/plug 9 position D-subminiature connector
Ground Binding post, accepts 4-mm plug or bare-wire connection
Line Power
Input voltage range 85 to 264 VAC, automatic selection
Input frequency range 50 to 440 Hz
Power requirement Approximately 50 VA (14 W)
Remote Programming
Interface GPIB interface operates to IEEE 488.2; RS-232 and RS-422 serial interface supplied as standard
Command language SCPI standard interface commands; 436A and 437B code compatible (E4418B only); 438A code compatible (E4419B only)
GPIB compatibility SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP1, DC1, DT1, C0
Battery
Battery type Lithium polycarbon monoflouride, approximate lifetime 5 years at 25 °C
Environmental (Operating)
Temperature 0 °C to 55 °C
Maximum humidity 95% at 40 °C (non-condensing)
Minimum humidity 15% at 40 °C (non-condensing)
Maximum altitude 3000 meters (9840 feet)
Storage Conditions
Storage temperature –20 °C to +70 °C
Non-operating maximum humidity 90% at 65 °C (non-condensing)
Non-operating maximum altitude 15240 meters (50,000 feet)
Safety and EMC
Safety EN61010-1: 1993/IEC 1010-1: 1990 +A1/CSA C22.2 No. 1010-1: 1993; EN60825-1: 1994/IEC 825-1: 1993 Class 1; Low Voltage Directive 72/23/EEC
EMC Complies with the EMC Directive 89/336/EEC; Generic Immunity Standard EN 50082-1: 1992; Radiated Interference Standard EN 55011: 1991/CISPR11:1990, Group 1 - Class A
Dimensions and Weight
Dimensions (exclude front and rear protrusions) 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in)
Net weight, E4418B 4.0 kg (8.8 lb)
Shipping weight, E4418B 7.9 kg (17.4 lb)
Net weight, E4419B 4.1 kg (9.0 lb)
Shipping weight, E4419B 8.0 kg (17.6 lb)
Important: Fast measurement-speed mode is available only with E-Series power sensors.
Important: Specifications describe the instrument's warranted performance and apply after a 30-minute warm-up, are valid over the operating/environmental range unless otherwise stated, and apply after performing a zero and calibration procedure.
Important: Power sensors are not included with the power meter and must be ordered separately. The EPM Series meters operate with Agilent E4410 and E9300 E-Series, 8480 Series, and N8480 Series average power sensors selected for the required frequency and power range.
Important: For Option E441XB-001, the 36-month warranty does not apply to the E9287A battery pack.
Recommended pairing: operate this meter with Agilent E4410/E9300 E-Series or 8480 Series average power sensors, connected using the 11730-series power sensor cables listed in the ordering information.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.