Agilent 4263B LCR Meter 100 Hz to 100 kHz (Pre-Owned)

Agilent 4263B LCR Meter 100 Hz to 100 kHz (Pre-Owned)

Regular price $2,495
Sale price $2,495 Regular price $0
In Stock
Shipping calculated at checkout.
Calibrations
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Agilent 4263B LCR Meter 100 Hz to 100 kHz (Pre-Owned)

Key Features At A Glance

  • Five test frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz (Option 002 adds 20 kHz)
  • 0.1% basic measurement accuracy with five-digit display resolution
  • 25 ms typical measurement time at SHORT setting for high system throughput
  • 11 impedance parameters: |Z|, R, X, |Y|, G, B, C, L, D, Q, θ
  • Built-in GPIB and isolated handler interfaces for automated test integration
  • Contact check function verifies reliability of test connections (5 ms typical)
  • Open, short, and load error correction with cable length compensation (0, 1, 2, 4 meters)
  • AC test signal level adjustable from 20 mV to 1 Vrms in 5 mVrms steps
Share on
View full details

The Agilent 4263B is an LCR meter covering a test frequency range of 100 Hz to 100 kHz, designed for fast measurements on components in applications that require both precision and versatility. The datasheet describes the instrument's performance as ranging from general bench-top impedance measurements to complex transformer, coil, and electrolytic capacitor measurements, with the design objectives of fast, reliable, and versatile testing at a low cost.

An LCR meter applies an AC test signal to a passive component and measures the resulting impedance to determine inductance (L), capacitance (C), and resistance (R) characteristics. The 4263B's listed applications include general bench-top impedance measurements, transformer testing, coil characterization, and electrolytic capacitor evaluation. With Option 001, the instrument adds turns-ratio, mutual inductance, and DC resistance measurement functions for transformer evaluation. The datasheet's electrolytic capacitor section highlights the built-in DC bias source, high-energy protection on the terminals, and fast system measurements for production throughput.

ValueTronics International has supplied new and pre-owned electronic test and measurement equipment to engineering, calibration, and production teams since 1992. The 4263B LCR meters in our catalog are stored, inspected, and tested at our 20,000 sq ft secure facility at 1675 Cambridge Drive, Elgin, Illinois, where our in-house technical staff verifies functionality against published specifications before any unit ships. Working directly with a stocking source — rather than a drop-ship broker or unverified marketplace listing — gives buyers a single accountable point of contact for condition questions, accessory completeness, calibration status, and post-sale support.

Brand Heritage

The 4263B was originally a Hewlett-Packard product. In 1999, HP spun off its test and measurement business as Agilent Technologies, and in 2014 Agilent's electronic measurement division was transferred to Keysight Technologies, which today supports the legacy Agilent T&M catalog. Buyers may encounter this instrument labeled as either HP or Agilent depending on production date; both branding generations are functionally the same product line.

Accessories Supplied

  • Power cable

Product Core & Specifications

Specification Value
Measurement Parameters / Ranges
|Z|, R, X 1 mΩ to 100 MΩ
|Y|, G, B 10 nS to 1000 S
C 1 pF to 1 F
L 10 nH to 100 kH
D 0.0001 to 9.9999
Q 0.1 to 9999.9
θ (phase angle) -180° to +180°
Δ -999.99% to 999.99%
DC Resistance (Option 4263B-001) 1 mΩ to 100 MΩ
Mutual Inductance (Option 4263B-001) 1 µH to 100 H (typical)
Turns-Ratio (Option 4263B-001) 0.9 to 200 (typical)
Measurement Conditions and Functions
Test Frequency 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz (Option 4263B-002 adds 20 kHz)
AC Test Signal Level 20 mVrms to 1 Vrms, 5 mVrms steps
Internal DC Bias +1.5 and +2.0 Vdc
External DC Bias 0 to +3.0 Vdc
Ranging Auto and Hold
Trigger Internal, Manual, and External
Trigger Delay Time 0 to 9999 ms in 1 ms steps
Test Cable Lengths 0, 1 meter @ f ≤ 100 kHz; 2 meter @ f ≤ 10 kHz (20 kHz); 4 meter @ f ≤ 1 kHz
Measurement Time (Short) 25 ms
Measurement Time (Medium) 65 ms
Measurement Time (Long) 500 ms
Basic Accuracy 0.1%
Contact Check Time (typical) 5 ms per measurement
Other Instrument Functions
Test Signal Level Monitor Voltage, current
Error Correction Open, Short, Load
Comparator HIGH, IN, and LOW for each displayed parameter
Save/Recall 10 instrument states from non-volatile memory
Front-end Protection Vmax = √(8/C) @ Vmax ≤ 250 V; Vmax = √(2/C) @ Vmax ≤ 1000 V (C in Farads)
Handler Interface Negative logic and isolated. Signals: HIGH/IN/LOW, No-Contact, EOM, Index, Alarm, Keylock, Ext. Trigger
GPIB Interface Instrument control, TALK-only mode for LISTEN-only printers using GPIB or Centronics/GPIB converter
Physical Characteristics
Power 90-132 Vac or 198-264 Vac, 47-66 Hz, 45 VA typical
Operating Temperature 0 to 45 °C
Dimensions (W × H × D) 320 mm × 100 mm × 300 mm
Weight 4.5 kg (typical)
Important: Test cable length settings are frequency-dependent: 4-meter cable operation is supported only at frequencies of 1 kHz or lower, and 2-meter cable operation is supported only at frequencies of 10 kHz or lower (20 kHz with Option 002). The full 100 kHz frequency range is available only with 0 or 1 meter cables.Important: Test fixtures are not furnished as standard with the 4263B. Select the appropriate fixture or test leads (e.g., 16034E/G/H, 16043A/B, 16044A, 16047A/E, 16048 series, 16060A, 16089 series) separately based on your DUT geometry.Important: Operation manual is not furnished as standard. One of the language options (e.g., 4263B-ABA for U.S. English) must be specified for the manual.Important: For the 16044A test fixture, one of the language options (ABA or ABJ) must be specified for the operation manual for shipment with product.Important: For the 16047E axial and radial test fixture, one of the language options (ABA or ABJ) must be specified for the operation manual for shipment with product.Important: Rack flange (4263B-1CM) and handle kit (4263B-1CN) are not compatible and cannot be ordered together.Recommended pairing: when measuring transformers, the Agilent 16060A Transformer Test Fixture provides fast connections for use with the 4263B's Option 001 N/M/DCR measurement functions. For surface-mount components, the 16034E/G/H series test fixtures are listed in the datasheet's accessory line.

About this used unit

  • Warranty included on all pre-owned 4263B units.
  • Functional verification performed in-house before shipment; performance checked against the parameters published in the Agilent 4263B datasheet.
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Frequency

100 kHz

1

Add N/M/DCR Measurement Function