HP 3437A System Voltmeter (Pre-Owned)

Key Features At A Glance

  • 3½-digit successive approximation system voltmeter with sampling rates up to 5,700 samples per second
  • Three input voltage ranges (0.1V, 1V, 10V) with 100% overrange capability and 1.0 MHz bandwidth on the 10V range
  • Chassis-isolated input terminals with floating measurement capability (±20V) for common-mode rejection ≥75 dB
  • HP-IB (IEEE-488) interface standard with all front panel functions programmable for system integration
  • Programmable digital delay logic delays external triggers from 0 to 1 second in 100 ns steps
  • Burst sampling capability — up to 9,999 readings per trigger at the maximum sample rate
  • Selectable output data format: ASCII (8-byte) or Packed binary (2-byte) for higher throughput data transfers
  • Binary Program mode provides abbreviated 7-byte program code for fast instrument reconfiguration
Share on
View full details

The HP 3437A System Voltmeter is a microprocessor-controlled, 3½-digit successive approximation voltmeter designed for system-level data acquisition applications requiring high sampling rates. The instrument samples voltages at rates up to 5,700 samples per second and provides chassis-isolated input terminals, a wideband input amplifier, auto-zero, auto-polarity, sample and hold, and 100% overrange on each of three voltage ranges (0.1 volt, 1 volt, and 10 volt). Floating measurement capability (±20 V) is supported over the frequency range of DC through 1.0 MHz on the 10V range.

Applications listed for the 3437A include fast multipoint data acquisition, repetitive-waveform analysis, low-frequency transient characterization, and low-frequency true RMS measurements. Additional system measurement applications cover waveform analysis (harmonic content, amplitude characteristics) and transient characterization. The instrument is positioned for bench measurements such as variable sample-rate DVM operation, oscilloscope accuracy enhancement (time-selective DVM), delay generation, and burst trigger generation.

ValueTronics International tests, stocks, and ships every unit out of our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Operating since 1992 and serving over 35,000 customers with more than 8,000 units in stock across 28 authorized new equipment partners and over 90 legacy brands, we provide a level of inventory depth and verification rigor that drop-shippers and pass-through brokers cannot match. Each instrument is professionally evaluated before listing — not merely forwarded from a third-party warehouse.

Brand Heritage

The 3437A was originally manufactured by Hewlett-Packard. HP's test and measurement business was spun out as Agilent Technologies in 1999, and Agilent's electronic measurement business subsequently became Keysight Technologies in 2014. Calibration support and service documentation for legacy HP test instruments routes through the Keysight service network where it remains available.

Product Core & Specifications

Voltage Measurement Characteristics
Range 0.1 V, 1 V, 10 V
Bandwidth (3 dB) - 10 V Range 1.0 MHz
Bandwidth (3 dB) - 1 V Range 1.1 MHz
Bandwidth (3 dB) - 0.1 V Range 40 kHz
Display - 10 V Range ±19.98 (max), ±99.99 (ovrld)
Display - 1 V Range ±1.998, ±9.999
Display - 0.1 V Range ±.1998, ±.9999
Static Accuracy (90 days, 23°C ±5°C) - 10 V Range ±0.05% of Reading ±1.6 Digits
Static Accuracy (90 days) - 1 V Range ±0.03% of Reading ±1.6 Digits
Static Accuracy (90 days) - 0.1 V Range ±0.06% of Reading ±1.8 Digits
Static Accuracy (1 year, 23°C ±5°C) - 10 V Range ±0.05% of Reading ±2.0 Digits
Static Accuracy (1 year) - 1 V Range ±0.03% of Reading ±2.0 Digits
Static Accuracy (1 year) - 0.1 V Range ±0.06% of Reading ±2.2 Digits
Static Accuracy Temperature Coefficient (0°C to 50°C) ±0.002% reading/°C ±0.05 digits/°C
Dynamic Accuracy - 10V Range, 10V Step ±200 mV within 700 ns; ±30 mV within 7.5 µs
Dynamic Accuracy - 1V Range, 1V Step ±20 mV within 700 ns; ±3 mV within 1.5 µs
Dynamic Accuracy - 0.1V Range, 0.1V Step ±200 µV within 25 µs
Delay Characteristics
Delay (NRDGS = 0 or 1) 0 to 0.9999999 sec in 100 ns steps
Delay (NRDGS > 1, ASCII) 277.8 µs to 0.9999999 sec
Delay (NRDGS > 1, Packed) 175.4 µs to 0.9999999 sec
Offset (actual delay with 0 delay programmed) 100 ns ±25 ns
Delay Accuracy ±0.008% Delay + Delay offset
Repeatability (Jitter) - Delay 0 or 100 ns 2 ns
Repeatability (Jitter) - Delay 200 ns to 50 ms 10 ns + 0.002% of Delay
Repeatability (Jitter) - Delay > 50 ms 110 ns
Number of Readings (per trigger) 0 to 9999
Input Characteristics
Input Impedance - 10 V Range 1 MΩ (±20%), <75 pF
Input Impedance - 1 V Range >108 Ω, <75 pF
Input Impedance - 0.1 V Range >108 Ω, <75 pF
Maximum Input Voltage HI to LO <±30 V Peak
Maximum Input Voltage LO to CHASSIS <±42 V Peak
Common Mode Rejection Ratio ≥75 dB (1 kΩ unbalance in low input lead at 60 Hz)
Programmability
Interface HP-IB (IEEE 488-1975)
HP-IB Capability AH1, C0, DC1, DT1, L4, PP0, RL1, SR1, SH1, T5
Maximum Reading Rate
ASCII Format 3600 Readings per second
Packed Format 5700 Readings per second
General
Power Requirements 100 V, 120 V, 220 V, 240 V (+5% -10%, 48-440 Hz), ≤42 VA
Operating Temperature 0°C to 50°C
Storage Temperature -40°C to +75°C
Humidity Range <95% RH (0°C to 40°C)
Dimensions 212.7 mm wide × 88.9 mm high × 527.1 mm deep
Net Weight 5.6 kg
Shipping Weight 7.6 kg
Important: Maximum input voltage: ±30 V peak (HI to LO, all ranges); ±42 V peak (LO to chassis).
Important: External trigger inputs exceeding TTL levels (0 to 5 V) may cause damage to the 3437A's external trigger input circuitry. The Performance Test trigger interface (-hp- 34113A) is useful for clamping bipolar triggers to within TTL levels.
Important: Verify that the 110 V/220 V Line Voltage Selection switch on the rear panel is set to the AC source voltage to be used before inserting the power cord and turning the instrument on. Also insure that the proper fuse is installed.
Important: Maximum Input Voltage: HI to LO < ±30 V Peak; LO to CHASSIS < ±42 V Peak (all ranges).
Important: Display will indicate overload if input is unterminated (0.1 volt range).

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.