Key Features at a Glance

  • True 8.5-digit resolution based on a 28-bit A/D converter
  • DC voltage to 1100 V; 1 nV resolution; >100 GΩ input impedance
  • Extended 128K reading memory configuration
  • Unique single-phase method for 4-wire ohms measurements
  • HP 3458A emulation mode
  • TRMS AC, average AC, peak AC, AC+DC, and crest factor measurement
  • 1 Hz to 15 MHz frequency counter with fully adjustable trigger level
  • Built-in 10-channel scanner option for scan-and-measure systems
  • IEEE-488.2 and SCPI compatible
View full details

In summary, the Keithley 2002/MEM2 is an 8.5-digit high-performance digital multimeter that delivers metrology-class accuracy at a fraction of the price of comparable instruments. It is based on the same measurement technology as the 7.5-digit 2001, but extends resolution and accuracy specifications for production test, design verification, and metrology applications where the highest accuracy is critical. The /MEM2 configuration ships with extended 128K reading memory.

What is the Keithley 2002/MEM2 used for?

The 2002 is used in calibration laboratories, metrology benches, and high-end production test where the resolution and accuracy of an 8.5-digit DMM are required. Common applications include DCV transfer measurements against standard cells, precision resistor characterization, low-frequency AC measurement, and any application where the measurement floor is set by the DMM's own noise and accuracy.

How does the 2002's 4-wire ohms method differ?

The 2002 uses a single-phase technique for 4-wire ohms measurement, which is twice as fast for a given power-line cycle rate as conventional DMMs. It also eliminates errors caused by changing lead resistance from fast test handlers, and includes built-in open-lead detection that eliminates many production-test problems.

Factual grounding — DCV transfer accuracy

Specification Value
200 mV range, 24-hour transfer ±(3.5 ppm rdg + 3 ppm rng)
2 V range, 24-hour transfer ±(1.2 ppm rdg + 0.3 ppm rng)
20 V range, 24-hour transfer ±(1.2 ppm rdg + 0.1 ppm rng)
200 V range, 24-hour transfer ±(5 ppm rdg + 0.4 ppm rng)
1000 V range, 24-hour transfer ±(5 ppm rdg + 0.08 ppm rng)
Input resistance >100 GΩ (200 mV to 20 V)

Entity authority

The 2002 sits in the same metrology tier as the HP/Agilent 3458A and is the standard 8.5-digit Keithley DMM in calibration laboratories. The 3458A emulation mode allows the 2002 to drop into existing 3458A-controlled metrology systems with minimal code change.

Applications

  • Calibration laboratories — ISO 17025 verification of precision sources
  • Standard-cell comparisons and DCV transfer measurements
  • Precision resistor characterization at ppm-level accuracy
  • Low-frequency AC measurement for vibration and control work
  • Peak-spike capture, frequency counting, and temperature measurement

Accessories Supplied

Accessory Description
Model 8605 High Performance Modular Test Leads
Documentation User's manual
Option slot cover Cover for the rear-panel scanner card option slot
Calibration Full calibration data

Product Core and Specifications

Like the 2001, the 2002 uses a 28-bit A/D and a patented AC measurement circuit that bypasses the prime error-contributing section of conventional RMS converters. The 2002 extends the 2001's resolution by an extra digit, sharpens 4-wire ohms speed and accuracy, and adds support for SPRTs (Standard Platinum Resistance Thermometers) to ITS-90 in addition to thermocouples and 100 Ω platinum RTDs.

AC voltage performance

Specification Value
200 mV / 2 V range, 0.1 to 2 kHz ±(0.02% rdg + 0.01% rng)
20 V / 200 V range, 2 to 10 kHz ±(0.04% rdg + 0.015% rng)
Bandwidth (typical) 1 Hz to 2 MHz
Crest factor measurement range 20 Hz to 1 MHz

Resistance, current, and frequency

Specification Value
4-wire ohms range 20 Ω to 1 GΩ (2-wire)
20 Ω 4W transfer accuracy ±(5 ppm rdg + 4.5 ppm rng)
DC current range 200 µA to 2 A
Frequency counter input 1 Hz to 15 MHz, ±0.03% rdg

General

Specification Value
Memory 128K readings (MEM2 configuration)
Power 90 to 134 V and 180 to 250 V universal self-selecting
Consumption <55 VA
Operating temperature 0 to 50 °C
Dimensions 90 mm H × 214 mm W × 369 mm D
Weight <4.2 kg (<9.2 lb)
EMC Conforms to VDE 0871B, IEC 801-2; FCC Part 15 Class B
Safety Conforms to IEC 348, CAN/CSA-C22.2 No. 231, MIL-T-28800E

Scanner Card Option

The 2002 accepts the same optional plug-in scanner cards as the 2001 (2000-SCAN, 2001-SCAN, 2001-TCSCAN). The scanner card converts the 2002 into a complete scan-and-measure system for up to 10 channels.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

2002/MEM2

Condition

New

Manufacturer

Keithley

Ac voltage

750 V

Dc voltage

1 kV

Resolution

8.5

Type

Bench