Fluke Calibration 1524-P3 Two-Channel Reference Thermometer Bundle with 5627A PRT, Universal TC INFO-CON Connector, TPAK, and Case

Fluke Calibration 1524-P3 Two-Channel Reference Thermometer Bundle with 5627A PRT, Universal TC INFO-CON Connector, TPAK, and Case

Regular price $4,660
Sale price $4,660 Regular price $0
Shipping calculated at checkout.
Request a Quote
Estimated Delivery in
5 - 7
business days (based on availability)

Request a Quote To Get An EDU Discount

Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Fluke Calibration 1524-P3 Two-Channel Reference Thermometer Bundle with 5627A PRT, Universal TC INFO-CON Connector, TPAK, and Case

Key Features At A Glance

  • Measures three sensor types from one tool: PRTs (–200 °C to 1000 °C), thermocouples (–200 °C to 2315 °C), and precision thermistors (–50 °C to 150 °C)
  • PRT accuracy up to ±0.011 °C; thermocouple accuracy ±0.24 °C for J, K, L, M types; precision thermistor accuracy ±0.002 °C
  • Dual-channel measurement with simultaneous readings, channel-to-channel temperature difference calculation, and 15,000 time and date stamped measurement logging
  • 128x64 backlit LCD graphical display plots and scales temperature trends in real time so stability is visible without statistics or long delays
  • INFO-CON connectors carry probe calibration coefficients in an embedded memory chip — plugging in the probe uploads conversion data automatically
  • Fast mode sample intervals: 0.3 seconds per sample for thermocouples and thermistors, 0.45 seconds per sample for PRTs
  • Accuracy specifications guaranteed from –10 °C to 60 °C ambient with current-reversal measurement to eliminate thermal EMFs
  • RS-232 serial interface standard with included 9940 software; runs 20+ hours on three AA batteries or continuously on the included AC adapter
View full details

The Fluke Calibration 1524 Reference Thermometer is a handheld two-channel readout that measures, graphs, and records temperature from three different sensor families — PRTs, thermocouples, and precision thermistors — through a single tool. It is the two-channel member of the 1523/1524 family, sharing every measurement feature of the single-channel 1523 while adding a second input channel, memory for 15,000 time and date stamped measurements, and a real-time clock for date-stamped logging.

The datasheet identifies calibration, loop checking, conformance testing, troubleshooting, maintenance, repair, and logging and validation as the applications this instrument is built for. Specific use locations called out include baths, dry-block calibrators, thermowells, clean rooms, engines, heat exchangers, furnaces, and freezers. The two-channel architecture is positioned for differential measurement work — testing internal and external combustion engines, turbines, steam systems, cooling towers, heat exchangers, and refrigeration systems where inlet-to-outlet temperature differences need to be measured, calculated, and recorded simultaneously.

ValueTronics is an authorized distributor for Fluke Calibration products and stocks the 1523 and 1524 Reference Thermometers in our 20,000 sq ft secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every unit is inventoried, inspected, and shipped directly from our facility — not drop-shipped from a third-party warehouse — so the instrument that ships is the instrument our team has hands on. Operating from a single owned facility since 1992, we keep both new authorized stock and verified pre-owned reference thermometers available, with our test and calibration team able to confirm condition and configuration before any unit leaves the building.

Brand Heritage

Fluke Calibration is the precision calibration instruments division of Fluke Corporation. The 1523 and 1524 readouts trace directly to the Hart Scientific product line; Hart Scientific was acquired by Fluke and the precision temperature calibration product family — including reference thermometer readouts, dry-block calibrators, and temperature baths — was consolidated under the Fluke Calibration brand. Hart Scientific instruments and the Fluke Calibration successors share the same engineering pedigree, calibration laboratory infrastructure, and the NVLAP-accredited temperature calibration capability (NVLAP Lab Code 200348-0) referenced in the datasheet.

Compare Other Models in This Series

The Fluke Calibration 1523/1524 Reference Thermometer family is a two-model handheld lineup sharing one measurement engine. Both readouts measure PRTs, thermocouples, and precision thermistors with the same accuracy specifications, the same INFO-CON probe interface, the same 128x64 backlit graphical display, and the same 12 thermocouple types. The structural difference is channel count and data logging capacity: the 1523 is a single-channel readout with memory for 25 readings plus statistics; the 1524 adds a second input channel, a real-time clock, and memory for 15,000 time and date stamped measurements.

Choosing between the two is an application question, not a precision question. Both instruments deliver the same per-measurement accuracy. The decision is whether the work requires simultaneous two-channel measurement (differential temperature, inlet-to-outlet comparisons, two devices under test in parallel) and whether data logging beyond the 25-reading manual save buffer is needed.

Each new 1523 and 1524 below is its own dedicated product page with condition-matched pricing, full configuration details, and current availability from our Elgin facility.

The 1524 is the right choice when the measurement scenario involves two sensors at the same time — engine inlet and outlet temperatures, two-zone process monitoring, simultaneous calibration of paired workload, or any scenario where channel-to-channel temperature difference is the result of interest. The 1524 calculates and displays the difference between channels directly. Memory for 15,000 time and date stamped measurements supports independent logging without a connected PC, which the datasheet specifically positions for space-constrained installations and field validation work.

The 1523 stores 25 readings with statistics — adequate for documentation of discrete check measurements but not for continuous time-stamped logging. The 1524 stores 15,000 time and date stamped measurements with a real-time clock, supports user-selectable sample rates from seven per second down to once per hour, and accepts probes on both Channel 1 and Channel 2 (Channel 1 accepts PRT, thermocouple, or thermistor; Channel 2 accepts PRT or thermistor per the rear-panel detail).

Both readouts share identical PRT, thermocouple, and thermistor accuracies; the same –10 °C to 60 °C ambient operating range with best accuracy from 13 °C to 33 °C; the same RS-232 serial interface; and the same 3-AA-battery power architecture with 20+ hours of runtime or continuous operation from the included AC adapter. See the comparison table below for the channel-count and logging-capacity differences side by side.

Model Input Channels Logging Capacity Sample Interval (Fast)
1524-P3 2 25 readings with statistics; 15,000 time and date stamped 0.3 seconds
1523 1 25 readings with statistics 0.3 seconds
1524 2 25 readings with statistics; 15,000 time and date stamped 0.3 seconds
1523-P1 1 25 readings with statistics 0.3 seconds

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • 1524 Reference Thermometer Readout
  • 5627A PRT
  • Universal TC INFO-CON Connector
  • TPAK Meter Hanging Kit
  • Case
  • 3 AA batteries
  • AC adapter with power cord
  • RS-232 cable
  • Users guide
  • Documentation CD
  • Report of calibration and calibration label
  • Clamp-on ferrite(s)

Product Core & Specifications

Specification 1523 1524
Input Channels 1 2
Logging 25 readings with statistics 25 readings with statistics; 15,000 time and date stamped
Sample interval (normal) 1 second 1 second (simultaneous measurement)
Typical sample interval (fast mode) 0.3 seconds 0.3 seconds
Sensor types PRTs, RTDs, Thermistors, and Thermocouples
Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
Operating temperature –10 °C to 60 °C (Best accuracy 13 °C to 33 °C)
Power requirements 3 AA alkaline batteries
Safety EN 61010-1:2001, CAN/CSA C22.2 No. 61010.1-04
Size (H x W x L) 96 mm x 200 mm x 47 mm (3.75 in x 7.9 in x 1.86 in)
Weight 0.65 kg (1.4 lb)
Millivolt range and accuracy –10 mV to 75 mV ± (0.005 % + 5 µV)
Resistance range and accuracy 0 Ω to 400 Ω ± (0.004 % + 0.002 Ω); 200 Ω to 50 kΩ ± (0.01 % + 0.5 Ω); 50 kΩ to 500 kΩ ± (0.03 %)
Temperature coefficient, voltage (–10 °C to 13 °C, +33 °C to 60 °C) ± (0.001 %/°C + 1 µV/°C)
Temperature coefficient, resistance (–10 °C to 13 °C, +33 °C to 60 °C) 0.0008 %/°C + 0.0004 Ω (0 Ω to 400 Ω); 0.002 %/°C + 0.1 Ω (0 Ω to 50 kΩ); 0.06 %/°C + 0.1 Ω (50 kΩ to 500 kΩ)
Excitation current, resistance 1 mA (0 Ω to 400 Ω); 10 µA (0 Ω to 50 kΩ); 2 µA (50 kΩ to 500 kΩ)

Equivalent Temperature Accuracies with Selected Probes (± °C)

T (°C) 5616-12 5615-6 5627A-12 5610-9
–200 0.014 0.025 0.027 n/a
0 0.021 0.021 0.049 0.009
100 0.027 0.028 0.065 0.030
300 0.040 0.043 0.103 n/a
420 0.050 n/a 0.130 n/a

Includes readout accuracy, probe calibration, and probe drift.

Thermocouple Temperature Accuracies

Type Range Measure Accuracies
B 600 °C to 800 °C
800 °C to 1000 °C
1000 °C to 1800 °C
0.85 °C
0.68 °C
0.57 °C
C 100 °C to 550 °C
550 °C to 2300 °C
0.32 °C
0.71 °C
E –200 °C to 0 °C
0 °C to 950 °C
0.52 °C
0.22 °C
J –200 °C to 0 °C
0 °C to 1200 °C
0.52 °C
0.23 °C
K –200 °C to 0 °C
0 °C to 1370 °C
0.61 °C
0.24 °C
L –200 °C to 0 °C
0 °C to 900 °C
0.36 °C
0.23 °C
M –20 °C to 0 °C
0 °C to 400 °C
400 °C to 1400 °C
0.26 °C
0.25 °C
0.22 °C
N –200 °C to 0 °C
0 °C to 1300 °C
0.72 °C
0.28 °C
R –20 °C to 0 °C
0 °C to 500 °C
500 °C to 1750 °C
1.09 °C
0.97 °C
0.49 °C
S –20 °C to 0 °C
0 °C to 500 °C
500 °C to 1750 °C
1.05 °C
0.95 °C
0.56 °C
T –200 °C to 0 °C
0 °C to 400 °C
0.60 °C
0.25 °C
U –200 °C to 0 °C
0 °C to 400 °C
0.54 °C
0.24 °C

Resolution (B, C, E, J, K, L, M, N, R, S, T, U): 0.10 °C. Accuracies are based on internal reference junction compensation. Refer to technical manual for equivalent accuracies with an external reference junction.

Important: Specifications are guaranteed across an ambient operating range of –10 °C to 60 °C, with best accuracy from 13 °C to 33 °C. Use within the 13 °C to 33 °C window when the published accuracy figures matter to the measurement result.Important: The 1523 and 1524 base-model Reference Thermometer readouts require an optional probe; a probe is not included with the standalone 1523 or 1524 readout SKUs. Order a bundled package (e.g., 1523-P1 through 1524-P4) or select a probe separately from the Accessories list.Important: The 5616 PRT (used in -P1 bundles) includes a NIST traceable calibration and is not RoHS (Restriction of Hazardous Substances) compliant.Important: The 5628, 5627A, and 5615 PRTs (used in -P2, -P3, and -P4 bundles) include a 17025 accredited calibration and are RoHS compliant.Important: Specifications are guaranteed from –10 °C to 60 °C ambient temperature, with best accuracy in the 13 °C to 33 °C range.Important: The 5609-9BND-P probe requires calibration (e.g., 1924-4-7) — not included.Recommended pairing: the datasheet lists multiple bundle configurations pairing the 1524 readout with Fluke Calibration 5616, 5628, 5627A, or 5615 PRTs plus a Universal TC INFO-CON Connector, TPAK magnetic hanger, and carrying case — see the 1524-P1 through 1524-P4 bundle configurations.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Fluke

Condition

New

Manufacturer

Fluke