Skip to content

The Keysight U2300A Series is a family of USB-connected modular multifunction data acquisition (DAQ) devices delivering PC-based measurement across two product groups. The basic multifunction family includes the U2351A, U2352A, U2353A, and U2354A with 16 single-ended (8 differential) channels at 250 kSa/s or 500 kSa/s. The high-density multifunction family includes the U2355A, U2356A, and U2331A with 64 single-ended (32 differential) channels, scaling up to 3 MSa/s single-channel sampling on the U2331A. Each device combines analog input, digital I/O, counter/timer, and on select models analog output and waveform generation in a single compact USB module.
The U2300A Series is positioned for research and development, manufacturing test, and design validation environments where multi-parameter electrical measurements must be acquired, logged, and analyzed on a host PC. Specific use cases called out for the family include applications spanning industrial and education settings where fast sampling, channel density, and flexible trigger configuration are required. The optional U2802A 31-channel thermocouple input signal conditioner extends the U2355A and U2356A into temperature measurement for product thermal analysis and characterization, environmental chamber profiling, process monitoring in consumer electronics, material properties testing, study of electronic temperature properties, and appliance testing using J, K, R, S, T, N, E, and B thermocouple types per the NIST ITS-90 database.
Keysight Technologies was spun off from Agilent Technologies in 2014, and Agilent had earlier been separated from Hewlett-Packard in 1999 as the test and measurement business. Instruments in the U2300A Series carry the engineering and calibration lineage of the HP and Agilent T&M heritage and are supported through Keysight's current service network.
The U2300A Series is divided by the datasheet into two product groups. The basic multifunction USB DAQ family — U2351A, U2352A, U2353A, U2354A — provides 16 single-ended (8 differential) channels with 16-bit resolution and sample rates of either 250 kSa/s (U2351A, U2352A) or 500 kSa/s (U2353A, U2354A). The high-density multifunction USB DAQ family — U2355A, U2356A, U2331A — provides 64 single-ended (32 differential) channels, with the U2355A at 16-bit/250 kSa/s, the U2356A at 16-bit/500 kSa/s, and the U2331A at 12-bit/3 MSa/s (single channel) or 1 MSa/s (multiple channels).
All seven models share a common architectural foundation: 24-bit programmable digital I/O, two general-purpose up/down counters, internal and external trigger options including SSI/Star trigger for chassis-based multi-module synchronization, Hi-Speed USB 2.0 with USBTMC-USB488, SCPI/IVI-COM programming, and self-calibration against a 5 V on-board reference. The model differences come down to channel density, ADC resolution and sample rate, and whether analog output is included.
Each pre-owned model below is its own dedicated product page with its own pricing, availability, and accessories list. Confirm the configuration that matches your channel count, sample rate, resolution, and analog output requirement before ordering.
The most consequential differences across the family are channel count, sample rate, and ADC resolution. Channel count splits cleanly: 16 SE / 8 DI on the basic family, 64 SE / 32 DI on the high-density family. Sample rate steps through 250 kSa/s (U2351A, U2352A, U2355A), 500 kSa/s (U2353A, U2354A, U2356A), and 3 MSa/s single-channel / 1 MSa/s multi-channel (U2331A). ADC resolution is 16-bit on every model except the U2331A, which trades resolution for speed at 12-bit.
Analog output presence is the other axis. The U2351A, U2353A, U2355A, U2356A, and U2331A include two analog output channels with 1 MSa/s update rate and predefined sine/square/triangle/sawtooth/noise waveform generation. The U2352A and U2354A omit analog output entirely — choose these when the application is input-only and the AO channels would go unused. Output resolution is 16-bit on the U2351A, U2353A, U2355A, and U2356A, and 12-bit on the U2331A.
| Model | Analog Input Channels | Max Sampling Rate | AI Resolution |
|---|---|---|---|
| U2331A | 64 SE/32 DI | 3 MSa/s (single ch); 1 MSa/s (multi-ch) | 12 bits |
| U2351A | 16 SE/8 DI | 250 kSa/s | 16 bits |
| U2352A | 16 SE/8 DI | 250 kSa/s | 16 bits |
| U2353A | 16 SE/8 DI | 500 kSa/s | 16 bits |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| General Characteristics | |
| Remote interface | Hi-Speed USB 2.0, USBTMC-USB488 |
| Power requirement | +12 VDC (typical), 2 A (max) input rated current |
| Power consumption | +12 VDC, 550 mA maximum |
| Operating temperature | 0 °C to +55 °C |
| Relative humidity | 15% to 85% RH (non-condensing) |
| Altitude | Up to 2000 meters |
| Pollution Degree | 2 (indoor use only) |
| Storage temperature | −20 °C to 70 °C |
| Safety compliance | IEC 61010-1:2001/EN 61010-1:2001 (2nd Edition); USA: UL61010-1: 2004; Canada: CSA C22.2 No.61010-1:2004 |
| EMC compliance | IEC/EN 61326-1 1998; CISPR 11: 1990/EN55011:1991, Class A, Group 1; Canada: ICES-001: 1998; Australia/New Zealand: AS/NZS 2064.1 |
| Shock and vibration | Tested to IEC/EN 60068-2 |
| I/O connector | 68-pin female VHDCI Type |
| Module dimensions (W × D × H) | 120.00 mm × 182.40 mm × 44.00 mm (with plastic casing); 105.00 mm × 174.54 mm × 25.00 mm (without plastic casing) |
| Terminal block dimensions | 103.00 mm × 85.20 mm × 42.96 mm |
| Weight | 565 g (with plastic casing); 400 g (without plastic casing) |
| Analog Input (Common) | |
| Scan list memory | Up to 100 selectable channel entries |
| Input coupling | DC |
| Input impedance | 1 GΩ / 100 pF |
| Operational common mode voltage range | ±7.5 V maximum |
| Overvoltage protection | Power-on: Continuous ±30 V; Power-off: Continuous ±15 V |
| Trigger sources | External analog/digital trigger, SSI/Star trigger |
| Trigger modes | Pre-trigger, delay-trigger, post-trigger, and middle-trigger |
| FIFO buffer size | Up to 8 MSa |
| Digital I/O | |
| Number of channels | 24-bit programmable input/output |
| Compatibility | TTL |
| Input voltage | VIL = 0.7 V max, IIL = 10 μA max; VIH = 2.0 V min, IIH = 10 μA max |
| Input voltage range | −0.5 V to +5.5 V |
| Output voltage | VOL = 0.45 V max, IOL = 8 mA max; VOH = 2.4 V min, IOH = 400 μA max |
| General Purpose Digital Counter | |
| Maximum count | (231−1) bits |
| Number of channels | Two independent up/down counter |
| Compatibility | TTL |
| Clock source | Internal or external |
| Base clock available | 48 MHz |
| Maximum clock source frequency | 12 MHz |
| Input frequency range | 0.1 Hz to 6 MHz at 50% duty cycle |
| Pulse width measurement range | 0.167 μs to 178.956 s |
| Analog Trigger | |
| Trigger source | All analog input channels, External analog trigger (EXTA_TRIG) |
| Trigger level | ±Full scale for internal; ±10 V for external |
| Trigger conditions | Above high, below low, and window (software selectable) |
| Trigger level resolution | 8 bits |
| Bandwidth | 400 kHz |
| Input impedance for EXTA_TRIG | 20 kΩ |
| Coupling | DC |
| Overvoltage protection | Continuous for ±35 V maximum |
| Digital Trigger | |
| Compatibility | TTL/CMOS |
| Response | Rising or falling edge |
| Pulse width | 20 ns minimum |
| Calibration | |
| On board reference voltage | 5 V |
| Temperature drift | ±2 ppm/°C |
| Stability | ±6 ppm/1000 hrs |
| General | |
| Device class | USBTMC-USB488 |
| Programmable interface | Standard Commands for Programmable Instruments (SCPI) and IVI-COM |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Keysight
Condition
Used
Manufacturer
Agilent