Key Features At A Glance

  • Two channel-to-channel isolated inputs rated CAT III 600 V for floating high-voltage measurements
  • Bandwidth spanning 100 MHz to 200 MHz across the two-model series
  • 5.7-inch VGA TFT LCD with indoor, outdoor, and night-vision viewing modes
  • Sample rate up to 2 GSa/s and memory depth up to 2 Mpts across the series for capturing glitches
  • Integrated 10,000-count digital multimeter with automatic polarity indication
  • USB 2.0 full-speed host and client ports with data logging to a PC
  • Ten selectable user-interface languages
View full details

The Agilent U1610A/U1620A is a handheld digital oscilloscope built around a 5.7-inch VGA display and two channel-to-channel isolated inputs. It pairs 100/200 MHz bandwidth with floating measurement capability on two CAT III 600 V isolated channels, and reaches up to 2 GSa/s sampling with 2 Mpts of memory depth to capture waveforms from signals such as pulse-width-modulated circuits, in-rush, transient, and motor start-up sequences. A benchtop-like display and dual-window zoom let an operator identify problem areas and zoom in for more detailed analysis.

An oscilloscope of this type displays voltage against time so an engineer can see a signal's amplitude, timing, and shape. Because each channel is individually isolated from the other and from non-isolated system components, technicians can take floating measurements and work with high-voltage and transient signals directly in the field. The waveform types called out for this instrument are pulse-width-modulated circuits, in-rush currents, transients, and motor start-up sequences, captured as non-repeating events over a wider time base.

ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, giving buyers a single accountable source for both new and pre-owned test equipment. Every used unit is inspected and functionally verified in-house before it ships, while new units ship factory-sealed exactly as received from the manufacturer.

Brand Heritage

Agilent Technologies began as the test-and-measurement business of Hewlett-Packard, which spun it off as an independent company in 1999. In 2014, that electronic measurement business was renamed Keysight Technologies. This instrument and its specifications were published under the Agilent Technologies name.

Compare Other Models in This Series

The U1610A/U1620A handheld oscilloscope family comprises two models that share the same isolated dual-channel architecture, 5.7-inch VGA TFT LCD display, integrated 10,000-count digital multimeter, and CAT III 600 V channel-to-channel isolation. Both deliver floating-measurement capability and the same indoor, outdoor, and night-vision viewing modes.

What separates the two models is acquisition performance: the U1610A provides 100 MHz bandwidth while the U1620A provides 200 MHz, with corresponding differences in maximum sample rate and memory depth. The trigger set, multimeter, math functions, and display system are common to both.

Each pre-owned model below is its own dedicated product page with condition-matched pricing. Select the model whose bandwidth and acquisition specifications match your application, then choose the listing that fits your required condition and budget.

The U1620A is specified at 200 MHz bandwidth, up to 2 GSa/s interleaved sample rate (1 GSa/s per channel), and up to 2 Mpts of interleaved memory depth, with a fastest timebase of 2 ns/div, 40 ps timebase resolution, and 1.75 ns typical calculated rise time.

The comparison table that follows lists the model-by-model differences. The U1610A is specified at 100 MHz bandwidth, 1 GSa/s interleaved (500 MSa/s per channel) sample rate, and 120 Kpts interleaved memory depth, with a fastest timebase of 5 ns/div, 100 ps timebase resolution, and 3.50 ns typical calculated rise time.

The U1620A doubles the bandwidth to 200 MHz and raises the interleaved sample rate to 2 GSa/s and interleaved memory depth to 2 Mpts, with a 2 ns/div fastest timebase, 40 ps resolution, and 1.75 ns typical rise time. Aside from these acquisition figures, the two models are functionally identical.

Model Bandwidth Sample Rate Memory Depth
U1620A 200 MHz 2 GSa/s interleaved, 1 GSa/s per channel 2 Mpts/channel (interleave), 1 Mpts/channel (non-interleave)
U1610A 100 MHz 1 GSa/s interleaved, 500 MSa/s per channel 120 Kpts/channel (interleave), 60 Kpts/channel (non-interleave)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Quick start guide
  • Power adapter
  • Li-Ion battery pack
  • USB cable
  • Test lead
  • 10:1 probe (2 sets)
  • Certificate of Calibration (CoC)

Product Core & Specifications

Specification Value
Vertical System
Bandwidth (-3 dB) 200 MHz
DC vertical gain accuracy ± 4% of full scale (full scale is equivalent to 8 div)
Dual cursor accuracy ± {DC vertical gain accuracy + 0.4% full scale (~1 LSB)} = ± {4% full scale ± 0.4% full scale (~1 LSB)}
Acquisition
Maximum sample rate 2 GSa/s interleaved, 1 GSa/s per channel
Maximum waveform memory depth 2 Mpts/channel (interleave), 1 Mpts/channel (non-interleave)
Vertical resolution 8 bits
Peak detection > 5 ns
Average Selectable from 2 to 8192 in powers-of-2 increments
Filter 10 kHz and 20 MHz bandwidth limiters
Interpolation (Sin x)/x
Vertical System (continued)
Analog channels Channel 1 and Channel 2 simultaneous acquisition
Calculated rise time 1.75 ns typical
Vertical scale 2 mV/div to 50 V/div
Maximum input CAT III 600 V (with 10:1 probe); CAT III 300 V (direct)
Offset (position) range ± 4 div
Dynamic range ± 8 div
Input impedance 1 MΩ ± 1% ≈ 22 pF ± 3 pF
Coupling DC, AC
Bandwidth limit 10 kHz and 20 MHz (selectable)
Channel-to-channel isolation (with channels at the same V/div) CAT III 600 V
Probes U1560-60002 1:1 passive probe; U1561-60002 10:1 passive probe; U1562-60002 100:1 passive probe
Probe attenuation factors 1x, 10x, 100x
Probe compensation output 5 Vpp, 1 kHz
Noise peak-to-peak (typical) 3% of full scale or 5 mVpp, whichever greater
DC vertical offset (position) accuracy ± 0.1 div ± 2 mV ± 1.6% offset value
Single cursor accuracy ± {DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~½ LSB)} = ± {4% full scale ± 0.1 div ± 2 mV ± 1.6% offset value + 0.2% full scale (~½ LSB)}
Horizontal System
Range 2 ns/div to 50 s/div
Resolution 40 ps for 2 ns/div
Timebase accuracy 25 ppm
Reference position Left, center, right
Delay range (pre-trigger) 1 screen width or 1 ms (whichever less)
Delay range (post-trigger) 20 ms to 500 s
Delay resolution 40 ps for 2 ns/div
Delay time measurement accuracy Same channel: ± 0.0025% reading ± 0.17% screen width ± 60 ps; Channel-to-channel: ± 0.0025% reading ± 0.17% screen width ± 120 ps
Modes Main, zoom, XY, roll
Horizontal pan and zoom Dual window zoom
Trigger System
Sources Channel 1, Channel 2, External
Modes Normal, Single, Auto
Types Edge, Glitch, TV, Nth Edge, CAN, LIN
Autoscale Finds or displays active channels, sets the edge trigger type on the highest numbered channel, and sets the vertical sensitivity on the scope channel timebase to display ~2 periods; requires > 10 mVpp minimum voltage, 0.5% duty cycle, and > 50 Hz minimum frequency
Holdoff time 60 ns to 10 s
Range ± 6 div from center of screen
Sensitivity ≥ 10 mV/div: 0.5 div; < 10 mV/div: greater of 1 div or 5 mV
Trigger level accuracy ± 0.6 div
Coupling modes AC (~10 Hz), DC, LF-Reject (~35 kHz), HF-Reject (~35 kHz)
External trigger — input impedance 1 MΩ ≈ 10 pF
External trigger — maximum input CAT III 300 V
External trigger — range DC coupling: trigger level ± 5 V
External trigger — bandwidth 100 kHz
Measurement
Automatic measurements Delay, duty cycle (+/–), fall/rise time, frequency, period, phase shift, T-max, T-min, width (+/–), amplitude, average, base, crest, cycle mean, maximum, minimum, overshoot, peak-to-peak, preshoot, standard deviation, top, Vrms (AC/DC), active/apparent/reactive power, power factor
Waveform math functions CH1 + CH2, CH1 – CH2, CH2 – CH1, CH1 × CH2, CH1/CH2, CH2/CH1, d/dt (CH1), d/dt (CH2), ∫(CH1)dt, ∫(CH2)dt, FFT
Cursors Delta V: voltage difference between cursors; Delta T: time difference between cursors
FFT points 1024
FFT windows Rectangular, Hamming, Hanning, Blackman-Harris, Flattop
Display System
Display 5.7" TFT LCD VGA Color (outdoor readable)
Resolution VGA (screen area): 640 vertical by 480 horizontal
Control Vectors on/off, sin x/x interpolation on/off, infinite persistence on/off, backlight intensity, color scheme, clear display
Real-time clock Date and time (adjustable)
Language 10 languages (selectable)
Built-in help system Functional quick help displayed by pressing the [Help] button
Storage System
Save/recall (non-volatile) 10 setups and waveforms can be saved and recalled internally
Storage mode USB 2.0 full speed host port; image formats: .bmp (8-bit, 24-bit) and .png (24-bit); data format: .csv
I/O USB 2.0 full-speed host, USB 2.0 full-speed client
Printer compatibility PCL Inkjet, PCL Laser
Digital Multimeter — General
Maximum reading 10,000 counts with automatic polarity indication
Voltage CAT II 1000 V or CAT III 600 V
Important: Maximum input: CAT III 600 V with a 10:1 probe, CAT III 300 V direct.
Important: Specifications denote warranted figures (all others typical) and are valid only after a 30-minute warm-up period and within 23 ± 10 °C of the last calibration temperature.
Important: Digital multimeter voltage inputs are only allowed to measure up to CAT III 600 V if referring to ground; the 1000 V DC/AC range is only allowed for floating voltage measurement.
Important: Operating temperature is limited to 0 to 40 °C when running on the power adapter (0 to 50 °C on battery only).
Recommended pairing: the U1562A 100:1 scope probe rated CAT III 600 V, listed among the recommended accessories, for higher-voltage probing.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Pre-Owned

Manufacturer

Keysight Technologies

Osc_ch

2

Osc_freq

200 MHz

Osc_r

1 MΩ

Osc_sampl

2 GSa/s interleaved, 1 GSa/s per channel