Skip to content

The RH300 is a compact digital psychrometer that simultaneously displays relative humidity, air temperature, and either dew point, wet bulb, or external probe temperature on a single screen. Its compact form makes it well-suited for field applications, and a unique sensor cap twists to a closed position to protect the sensor during storage.
A psychrometer characterizes the moisture state of air by relating humidity, temperature, and the derived dew point and wet bulb values. The RH300 performs wet bulb measurements without slinging, and using the optional TP890 thermistor temperature probe it calculates a T1-T2 differential (air temperature minus external probe temperature) as well as a T2-minus-dew-point value. Data Hold, Max/Min readings, and Auto Power Off round out the operating feature set.
ValueTronics stocks and holds its own inventory in a 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.
The Extech brand operates as part of FLIR Systems, Inc., which holds the copyright on this product line. The two names reflect a single corporate relationship rather than separate manufacturers.
| Parameter | Range | Max Resolution | Basic Accuracy |
|---|---|---|---|
| Humidity | 10 to 90%RH | 0.1%RH | ±3%RH |
| Temperature (internal) | -4 to 122°F (-20 to 50°C) | 0.1° | ±1.8°F or ±1°C |
| Temperature (external) | -4 to 158°F (-20 to 70°C) | 0.1° | ±1.8°F or ±1°C |
| Dew Point | -90.4 to 122°F (-68.0 to 49.9°C) | 0.1° | — |
| Wet Bulb | -6.9 to 122°F (-21.6 to 49.9°C) | 0.1° | — |
| Dimensions / Weight | |||
| Dimensions | 7 x 1.9 x 1" (178.5 x 48.4 x 24.7 mm) | — | — |
| Weight | 3.3 oz (95 g) | — | — |
Important: The external temperature probe (TP890) is optional and is not included with the base unit; it is required to measure external temperature and to calculate the T1-T2 differential (air temperature minus external probe temperature) and T2-dew point.
Important: This product is available with optional calibration traceable to NIST — order with -NIST after the part number.
Recommended pairing: use the optional Extech TP890 Thermistor Temperature Probe to enable external temperature measurement and the T1-T2 differential calculation.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Extech
Condition
Factory New
Manufacturer
Extech
Request A Quote