Key Features At A Glance

  • Frequency range from 10 MHz to 67 GHz with 1 Hz frequency resolution and ±1 ppm frequency accuracy
  • Available as 2-port (Option 200) or 4-port (Option 400) configurations with optional extended power range, internal second source, combiner, and mechanical switches
  • Optional hardware and firmware for high-accuracy noise figure measurements (Option 029) requires Option 224 or 423
  • LAN, GPIB (dual-port), USB 2.0, and Handler I/O standard for automated test system integration; LXI Class C compliant
  • System IF bandwidth range from 1 Hz to 15 MHz (7/10/15 MHz IFBWs require FW A.09.42 and later with DSP version 5)
  • Test ports use 1.85 mm (male) connectors with 50 ohm nominal impedance
  • 26.3 cm (10.4 in) color active matrix LCD with 1024 × 768 resolution; rear-panel VGA video output included
Share on
View full details

The Agilent N5247A is a PNA-X series vector network analyzer covering 10 MHz to 67 GHz. The N5247A is offered with multiple test set configurations, including 2-port (Option 200) and 4-port (Option 400) base units, with optional extended power range, internal second source, mechanical switches, and high-accuracy noise figure measurement hardware (Option 029).

The N5247A is used for measurements that include S-parameter network analysis, reflection and transmission measurements, group delay measurements, and — with Option 029 — high-accuracy noise figure measurements. The instrument's specifications cover dynamic accuracy verification through compression-over-frequency and IF linearity measurements, and the analyzer supports both filtered and high-power source modes for harmonic management versus output power optimization.

ValueTronics International, LLC has supported test and measurement professionals since 1992 from our 20,000 square foot warehouse and testing facility at 1675 Cambridge Drive in Elgin, Illinois. Every {{CONDITION}} N5247A passing through our facility is handled by our in-house team — not drop-shipped from a third party — which is why the documentation, accessory verification, and post-sale support our customers receive on RF and microwave instruments at this level reflect a direct relationship with the people who stocked, evaluated, and shipped the unit.

Brand Heritage

The N5247A was introduced under the Agilent Technologies brand. Agilent's electronic test and measurement business was transferred to Keysight Technologies in 2014, and the PNA-X product family has continued under Keysight since that transition. Agilent itself was originally spun off from Hewlett-Packard in 1999.

Product Core & Specifications

Specification Value
Frequency Information
Frequency Range 10 MHz to 67 GHz (typical to 70 GHz)
Frequency Resolution 1 Hz
Frequency Accuracy +/- 1 ppm
Frequency Stability +/-0.05 ppm, -10° to 70° C (typical); +/-0.1 ppm/yr maximum (typical)
System Dynamic Range (Specification, Options 200/400, Ports 1,3)
10 MHz to 50 MHz 74 dB
50 MHz to 100 MHz 100 dB
100 MHz to 500 MHz 108 dB
500 MHz to 1 GHz 118 dB
1 GHz to 2 GHz 123 dB
2 GHz to 3.2 GHz 125 dB
3.2 GHz to 10 GHz 128 dB
10 GHz to 13.5 GHz 127 dB
13.5 GHz to 16 GHz 129 dB
16 GHz to 19 GHz 128 dB
19 GHz to 24 GHz 129 dB
24 GHz to 26.5 GHz 129 dB
26.5 GHz to 30 GHz 116 dB
30 GHz to 32 GHz 113 dB
32 GHz to 35 GHz 115 dB
35 GHz to 40 GHz 110 dB
40 GHz to 50 GHz 112 dB
50 GHz to 60 GHz 111 dB
60 GHz to 64 GHz 110 dB
64 GHz to 67 GHz 110 dB
Test Port Compression at 0.1 dB (Typical)
10 MHz to 10 GHz 15 dBm
10 GHz to 30 GHz 12 dBm
30 GHz to 67 GHz 11 dBm
Damage Input Level (Specification)
Test Ports 1, 2, 3, 4 (All Options) > +24 dBm RF; 40 V DC
Source 2 Out 1, Source 2 Out 2 (Option 224 only) > +24 dBm RF; 0 V DC
Test Port 1, Noise Mode (Option 029 only) > +10 dBm RF; 40 V DC
Test Port 2, Noise Mode (Option 029 only) > +27 dBm RF; 40 V DC
Reference Level
Range (Magnitude) +/-500 dB
Range (Phase) +/-500 degrees
Resolution (Magnitude) 0.001 dB
Resolution (Phase) 0.01 degrees
Power Resolution and Settable Power
Power Resolution 0.01 dB
Maximum Settable Power (Typical) 30 dBm
Minimum Settable Power, Options 200/400 (Typical) -30 dBm
Minimum Settable Power, Options 219/419/224/423 (Typical) -80 dBm
Miscellaneous
System IF Bandwidth Range 1 Hz to 15 MHz (7/10/15 MHz IFBWs require FW A.09.42 or later, DSP version 5)
CPU Intel 2.0 GHz Core i7 (some instruments may have a different CPU)
LXI Class C
Front Panel
Test Ports 1.85 mm (male), 50 ohm nominal, 0.002 in. Center Pin Recession
Jumpers 1.85 mm (female) connectors with 1.85 mm (male) jumper cables
USB 2.0 Ports 4 Master ports, USB Type-A female
Display 26.3 cm (10.4 in) diagonal color active matrix LCD; 1024 x 768 resolution
Display Refresh Rate Vertical 60 Hz; Horizontal 46.08 kHz
Rear Panel
10 MHz Reference In BNC female; 10 MHz +/-10 ppm; -15 dBm to +20 dBm; 200 ohm nominal
10 MHz Reference Out BNC female; 10 MHz +/-1 ppm; +10 dBm +/-4 dB into 50 ohm; harmonics <-40 dBc typical
External IF Inputs SMA female; A, B, C, D, R (4-port) or A, B, R1, R2 (2-port); 50 ohm; RF damage +23 dBm
VGA Video Output 15-pin mini D-Sub
Bias Tee Inputs BNC(f) for ports 1, 2, 3, 4; 500 mA fuse; +/-200 mA max bias; +/-40 VDC max
Trigger Inputs/Outputs BNC(f), TTL/CMOS compatible
Test Set IO 25-pin D-Sub
Handler IO 36-pin parallel I/O port
GPIB Two ports; 24-pin D-sub female; IEEE-488 compatible
Parallel Port (LPT1) 25-pin D-Sub female
USB Ports (Rear) 5 ports (4 Host, 1 Device), USB 2.0 compatible
LAN 10/100BaseT Ethernet, 8-pin
Line Power Frequency/Voltage 50/60/400 Hz for 100-120 VAC; 50/60 Hz for 220-240 VAC; auto switching
Max Power 450 watts
Dimensions
Height (without bottom feet, EIA RU = 6) 266.1 mm (10.5 in)
Height (with bottom feet) 280.0 mm (11.0 in)
Width (without handles or rack-mount flanges) 425.9 mm (16.8 in)
Width (with handles, without rack-mount flanges) 458.7 mm (18.1 in)
Width (with handles and rack-mount flanges) 482.9 mm (19.0 in)
Depth (without front and rear panel hardware) 582.3 mm (22.9 in)
Depth (with front and rear panel hardware, handles) 649.6 mm (25.6 in)
Net Weight, 2-port (Option 224 with 029) 46.3 kg (102 lb)
Net Weight, 4-port (Option 423 with 029) 49.0 kg (108 lb)
Shipping Weight, 2-port (Option 224 with 029) 62.1 kg (137 lb)
Shipping Weight, 4-port (Option 423 with 029) 65.3 kg (144 lb)
Important: Test port damage input level: RF >+24 dBm, DC 40 V. For Option 224 Source 2 Out 1 and Source 2 Out 2: RF >+24 dBm, DC 0 V. With Option 029 in noise mode, Test Port 1 damage level is >+10 dBm RF / 40 V DC.Important: All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has been turned on.Important: Typical performance information between 67 GHz and 70 GHz is provided where available; performance is degraded at particular frequencies in this range due to the modes of the 1.85 mm connectors used in the analyzer, test port cables, and adapters.Important: Option 029 (high-accuracy noise figure) requires one of Option 224 or Option 423.Important: Option 219 requires Option 200. Option 224 requires Options 200, 219, and 080.Important: Option 419 requires Option 400. Option 423 requires Options 400, 419, and 080. Option 080 is recommended with Option 400.Important: Calibration of the analyzer is performed using a separately-ordered calibration kit (e.g., 85058B mechanical cal kit) or ECal module (e.g., N4694A 2-Port ECal). These cal standards are not included with the base analyzer and must be selected to match the application.Recommended pairing: the 85058B (1.85 mm) calibration kit and N4694A 2-port electronic calibration module are the calibration accessories whose corrected system performance is published with this analyzer's data sheet.

About this used unit

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Agilent

Condition

Used

Manufacturer

Agilent

Frequency

67 GHz