Skip to content

The Anritsu MG3690C is an RF/microwave signal generator family covering 0.1 Hz to 67 GHz across six base models, with operation to 70 GHz on the MG3697C and banded extension to 500 GHz through the optional 2000-1694 series millimeter-wave multipliers. The series is described by Anritsu as offering frequency coverage, phase noise, leveled output power, spectral purity, switching speed, modulation performance, size, upgradeability, reliability, and service suited to applications spanning R&D, manufacturing, and depot repair.
Signal generators of this class create the precise, known stimulus signals required to characterize RF and microwave components, simulate communication or radar waveforms, and drive devices under test in receiver sensitivity, intermodulation, and component characterization measurements. The MG3690C supports CW, phase-locked step sweep, list sweep with up to 2000 non-sequential frequency/power sets per table, manual sweep, alternate sweep between two ranges, and—with Option 6—analog sweep across the full frequency range with 30 ms to 99 second sweep times.
ValueTronics International has been a trusted source for new and pre-owned test and measurement equipment since 1992. Our 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois houses our inventory and our in-house technical operations, where instruments are inspected, performance-verified, and prepared for shipment. Buyers who choose ValueTronics work with a direct supplier rather than a drop-shipper or pass-through broker, with named contacts available for technical questions, calibration coordination, and post-sale support.
Anritsu Corporation is a Japanese precision measurement company with roots extending to 1895. Its current RF and microwave instrument portfolio was significantly shaped by the 1990 acquisition of Wiltron Company, which brought network analyzer and microwave signal generator technology and a North American commercial presence into the Anritsu family. Legacy Wiltron instruments are now part of the Anritsu lineage and continue to be supported through Anritsu's service organization.
The MG3690C family consists of six base models that share a common front panel, software platform, and option ecosystem but differ in their upper frequency limit and maximum output power. All six models cover a 2 GHz lower limit as standard; Options 4 and 5 extend the low end to 8 MHz, and Option 22 extends coverage down to 0.1 Hz using Direct Digital Synthesis. The MG3691C, MG3692C, MG3693C, and MG3694C use a K(f) output connector; the MG3695C and MG3697C use a V(f) connector.
Model selection is driven primarily by the highest frequency required for the application. The MG3697C operates to 67 GHz and is operational to 70 GHz, with millimeter-wave multipliers extending banded coverage as high as 500 GHz. Output power decreases at higher frequencies and on higher-frequency models, and is recovered through the High Power Option 15 when available bandwidth and budget allow.
Each model in the MG3690C family is listed as its own product page with condition-matched pricing. Whether you are evaluating a pre-owned unit at a specific model and frequency tier, or comparing models to find the right frequency coverage for your application, each page describes the configuration, specifications, and available options for that specific model.
The six models differ in maximum frequency coverage and corresponding maximum leveled output power. The MG3691C (2 GHz to 10 GHz) and MG3692C (2 GHz to 20 GHz) provide +19 dBm and +17 dBm respectively at their upper bands. The MG3693C (2 GHz to 31.8 GHz) and MG3694C (2 GHz to 40 GHz) provide +9 dBm above 20 GHz. The MG3695C (2 GHz to 50 GHz) delivers +6 dBm above 20 GHz and +3 dBm above 40 GHz.
Refer to the comparison table for full per-model power, frequency, and connector specifications. Option availability also varies: Option 7 (IF Up-Conversion) is not available on the MG3695C or MG3697C. Several Option 15 (High Power) variants exist with configuration-dependent suffixes (15A, 15B, 15C, 15D).
| Model | Frequency Range | Output Type | Max Output Power |
|---|---|---|---|
| MG3697C | 2 GHz to 67 GHz | V(f) | +10 dBm |
| MG3691C | 2 GHz to 10 GHz | K(f) | +19 dBm |
| MG3692C | 2 GHz to 20 GHz | K(f) | +19 dBm |
| MG3693C | 2 GHz to 31.8 GHz | K(f) | +15 dBm |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency Coverage (Base Models) | MG3691C: 2 GHz to 10 GHz; MG3692C: 2 GHz to 20 GHz; MG3693C: 2 GHz to 31.8 GHz; MG3694C: 2 GHz to 40 GHz; MG3695C: 2 GHz to 50 GHz; MG3697C: 2 GHz to 67 GHz (operational to 70 GHz) |
| Output Type | K(f) for ≤ 40 GHz models; V(f) for > 40 GHz models |
| Optional Frequency Extension | Option 4: 8 MHz to 2.2 GHz (Ultra-Low Phase Noise DDC); Option 5: 8 MHz to 2 GHz (Heterodyne); Option 22: 0.1 Hz to 10 MHz (DDS) |
| CW Mode Accuracy | Same as internal or external 10 MHz time base |
| Internal Time Base Stability (Aging) | < 2 x 10⁻⁹/day (< 5 x 10⁻¹⁰/day with Option 16) |
| Internal Time Base Stability (Temperature) | < 2 x 10⁻⁸/°C over 0 °C to 55 °C (< 2 x 10⁻¹⁰/°C with Option 16) |
| CW Resolution | 0.01 Hz |
| External 10 MHz Reference Input | 10 MHz ± 50 Hz (typical), 0 dBm to +20 dBm, 50 Ω BNC rear panel |
| 10 MHz Reference Output | 1 Vp-p into 50 Ω, AC coupled, BNC rear panel |
| Phase Offset | Adjustable in 0.1 degree steps |
| EFC Input | –4 V to +4 V, 8 x 10⁻⁸ Hz/V sensitivity (typical), ≤ 250 Hz modulation bandwidth, BNC high impedance rear panel |
| Phase-Locked Step Sweep Mode | |
| Sweep Width | Independently selected, 0.01 Hz to full range |
| Resolution (Minimum Step Size) | 0.01 Hz |
| Number of Steps | Variable from 1 to 10,000 |
| Dwell Time Per Step | Variable from 1 ms to 99 seconds |
| Fixed Rate Sweep | Variable from 20 ms to 99 seconds |
| Analog Sweep Mode (Option 6) | |
| Sweep Width | 1 MHz to full frequency range |
| Accuracy | Lesser of ± 30 MHz or ± 2 MHz + 0.25 % of sweep width for sweep speeds ≤ 50 MHz/ms (typical) |
| Sweep Time Range | 30 ms to 99 seconds |
| List Sweep Mode | |
| Storage | Up to 4 tables with 2000 non-sequential frequency/power sets |
| Programmable Frequency Agility | Up to 3202 non-sequential frequency/power sets, volatile memory |
| Markers | |
| Number of Markers | Up to 20 independent, settable markers (F0–F9 and M0–M9) |
| Video Markers | +5 V or –5 V marker output, AUX I/O connector rear panel |
| Switching Time (tsw) | |
| Step not crossing dwell frequencies | 5 ms + 1 ms/GHz |
| Step not crossing band switching frequencies | 7 ms + 1 ms/GHz (typical) |
| Step crossing band switching frequencies | 8 ms + 1 ms/GHz (typical) |
| RF Output | |
| Source Impedance | 50 Ω nominal |
| Source SWR (Internal Leveling) | < 2.0 typical |
| Output Power Resolution | 0.01 dB or 0.001 mV |
| Power Level Stability with Temperature | ± 0.04 dB/°C typical |
| Minimum Settable Output Power (Without Attenuator) | –20 dBm |
| Minimum Settable Output Power (With Attenuator) | –120 dBm |
| Minimum Leveled Output Power (Without Attenuator) | –15 dBm (–20 dBm typical) |
| AM Noise Floor | |
| AM Noise Floor | Typically < –145 dBm/Hz at 0 dBm output and offsets > 5 MHz from carrier |
| Modulation Options | |
| FM/ΦM (Option 12) | External, rear panel BNC, 50 Ω |
| AM (Option 14) | 0–90% linear, 20 dB log; DC to 50 kHz min, DC to 100 kHz typical bandwidth; ± 1 Vpk max input |
| Pulse (Option 26) | On/Off ratio > 80 dB (> 70 dB with Option 15); Min leveled pulse width 100 ns ≥ 1 GHz, 1 µs < 1 GHz; PRF 100 Hz to 5 MHz leveled, DC to 10 MHz unleveled |
| Internal LF and Pulse Generators (Option 27) | Sinusoid, square, triangle, ramps, Gaussian/uniform noise; 0.1 Hz to 10 MHz sine; 0.1 Hz to 1 MHz square/triangle/ramp |
| Remote Operation | |
| Interfaces | Ethernet (VXI-11 over TCP/IP) and GPIB (IEEE-488) |
| Ethernet Port | 10/100 Base-T |
| GPIB Commands | Native, SCPI |
| Emulations | Anritsu Models 6600, 6700, and 6XX00-series signal sources |
| Environmental (MIL-PRF-28800F, Class 3) | |
| Storage Temperature | –40 °C to +75 °C |
| Operating Temperature | 0 °C to +50 °C |
| Relative Humidity | 5 % to 95 % at 40 °C (non-condensing) |
| Altitude | 4,600 meters, 43.9 cm Hg |
| Safety Directive | EN 61010-1: 1993 + A1: 92 + A2: 95 |
| General | |
| Warm Up Time (From Standby) | 30 minutes |
| Warm Up Time (From Cold Start at 0 °C) | 120 hours to achieve specified frequency stability with aging |
| Power | 85 VAC to 264 VAC, 48 Hz to 440 Hz, 250 VA maximum |
| Weight | 18 kg maximum |
| Dimensions | 133 mm H x 429 mm W x 450 mm D |
| Warranty | 3 years from ship date |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Anritsu
Condition
Used
Manufacturer
Anritsu
Frequency
67 GHz
Request A Quote