Key Features At A Glance

  • Bandwidth from 4 GHz to 20 GHz across the series, matched on all four channels simultaneously
  • Real-time sample rate up to 50 GS/s with record length up to 200 Msamples on all four channels
  • FastAcq with DPX technology captures more than 300,000 waveforms/s on all four channels
  • Pinpoint triggering with over 1400 trigger combinations on both A and B trigger events
  • 12.1-inch XGA touch-screen display, the largest in its class
  • LAN (10/100/1000Base-T), GPIB (IEEE 488.2), RS-232, USB 2.0 and IEEE 1284 interfaces standard
  • Available in DPO70000 oscilloscope or dedicated DSA70000 digital serial analyzer configurations
  • Optional serial protocol decode/triggering and compliance modules via separate software licenses
View full details

The DPO/DSA70000 Series from Tektronix is a family of real-time digital phosphor oscilloscopes (the DPO70000 models) and dedicated digital serial analyzers (the DSA70000 models) built for engineers verifying, characterizing, debugging and testing sophisticated electronic designs. The two lines share the same acquisition architecture: the DPO70000 instruments deliver high-bandwidth waveform acquisition and analysis, while the specialized DSA70000 analyzers add a complete, dedicated solution for the challenges of high-speed serial designs. Both lines combine signal acquisition performance, operational simplicity, and an extensive set of debugging tools in a single benchtop instrument.

These instruments are applied to signal integrity, jitter and timing analysis; verification, debug and characterization of sophisticated designs; debugging and compliance testing of serial data streams for telecom and datacom industry standards; investigation of transient phenomena; and spectral analysis. The DSA70000 configuration is specifically targeted at high-speed serial design issues, encapsulating extended serial data domain expertise for verifying, characterizing, debugging and testing serial designs.

ValueTronics operates a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, where it stocks and holds its own inventory of test and measurement equipment. Every pre-owned unit is inspected and functionally verified in-house before it ships; new units ship factory-sealed exactly as received from the manufacturer.

Compare Other Models in This Series

The DPO/DSA70000 Series is offered in two parallel lines built on the same advanced acquisition technology. The DPO70000 line comprises real-time digital phosphor oscilloscopes for verifying, characterizing, debugging and testing sophisticated electronic designs, while the DSA70000 line comprises dedicated digital serial analyzers that inherit the same signal acquisition performance, operational simplicity and debugging tools but add extended high-speed serial data domain expertise.

Within each line, the models are distinguished primarily by bandwidth tier, with versions spanning 4, 6, 8, 12.5, 16 and 20 GHz on all four channels. Each model is a separate product page; the comparison table below summarizes how bandwidth, sample rate, rise time and record-length options differ across the family.

Each pre-owned model linked below is its own dedicated product page with condition-matched pricing. Select the bandwidth tier and DPO or DSA configuration that fits your application, then review that specific model's page for its pricing and availability.

The models differ first by bandwidth, from 4 GHz on the DPO70404/DSA70404 up to 20 GHz on the DPO72004/DSA72004, with corresponding rise-time figures improving across the tiers. Sample rate also tracks the tier: the 4, 6 and 8 GHz models provide 25 GS/s on all four channels, while the 12.5, 16 and 20 GHz models provide 50 GS/s on all four channels. Record-length options likewise scale, with up to 100 M samples available on the 4, 6 and 8 GHz models and up to 200 M samples available on the 12.5, 16 and 20 GHz models.

The DPO70000 and DSA70000 lines also differ in standard configuration: standard record length is 10 M samples per channel on the DPO70000 line versus 20 M on the DSA70000 line, and capabilities such as serial pattern triggering, protocol decode and serial data compliance and analysis are standard on the DSA70000 line but offered as licensed options on the DPO70000 line. Refer to the comparison table that follows for the exact per-model values.

Model Bandwidth Sample Rate Max Record Length (Std)
DSA71604 16 GHz 50 GS/s 20 M/ch
DPO70404 4 GHz 25 GS/s 10 M/ch
DPO70604 6 GHz 25 GS/s 10 M/ch
DPO70804 8 GHz 25 GS/s 10 M/ch

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Accessory pouch
  • Front cover
  • Mouse
  • Keyboard
  • Quick start user manual (071-173x-xx)
  • Probe calibration and deskew fixture
  • DPO70000 Series product software CD/DVD-ROM
  • DPO70000 Series operating system restoration CD/DVD-ROM
  • Optional applications software CD/DVD-ROM
  • Performance verification procedure PDF file
  • GPIB programmer's reference (on product software CD/DVD-ROM)
  • Calibration certificate documenting NIST traceability, Z 540-1 compliance and ISO9001
  • Power cord
  • One year warranty
  • Four TekConnect to 2.92 mm adapters (TCA-292MM)
  • One TekConnect to BNC adapter (TCA-BNC)

Product Core & Specifications

Specification Value
Vertical System
Input Channels 4
Bandwidth (user-selectable DSP enhance) 16 GHz
Rise Time 10% to 90% (typical) 27.5 ps
Rise Time 20% to 80% (typical) 21 ps
Hardware Analog Bandwidth (–3 dB) 16 GHz (typical)
Time Base System
Time Base Range 10 ps/div to 1000 s/div
Time Resolution (ET/IT mode) 100 fs
Delta Time Measurement Accuracy (typical, <100 ns duration, single shot) 482 fs
Jitter Noise Floor (typical, with BW+ bandwidth enhance enabled) 300 fs
Acquisition System
Real-time Sample Rate (1–4 channel, max) 50 GS/s
ET/IT Mode Sample Rate (max) 10 TS/s
Maximum Record Length per Channel (Standard) 20 M on all four channels
Record Length Opt. 5XL 50 M on all four channels
Record Length Opt. 10XL 100 M on all four channels
Record Length Opt. 20XL 200 M on all four channels
Important: Maximum input voltage (50 Ω): <5.5 VRMS for ≥1 V full scale; also determined by the TekConnect accessory.
Important: Probes are not included with the base instrument. An appropriate TekConnect-interface probe (e.g., P7516 16 GHz TriMode, P7513 13 GHz TriMode, P7313 13 GHz Z-Active differential, or P7380A 8 GHz Z-Active differential) must be ordered separately to connect to a device under test (see Recommended Accessories).
Important: Optional Ultra Wideband WiMedia Analysis (Opt. UWB) analyzes all data rates, Time Frequency Codes and Band Groups only on the DPO/DSA71604 or DPO/DSA72004 models.
Important: For Optional Power Measurement and Analysis (Opt. PWR), at least Opt. 2XL and a TCA-1MEG TekConnect 1 MΩ buffer amplifier are recommended for use.
Important: User must specify the quick start user manual language and the power plug when ordering.
Recommended pairing: use the P7516 or P7513 TriMode probes for bandwidth enhancement to the probe tip when capturing differential and single-ended signals.

About this Pre-Owned unit

This pre-owned unit is inspected and functionally verified in-house before it ships and is backed by our pre-owned warranty. To confirm its exact condition, firmware revision, installed options, or included accessories for your application before ordering, contact our Test Architects.

  • Warranty included
  • Functional verification included
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.
  • Note that unnecessary accessories may not be included (contact Test Architect to confirm).

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

Model No

Tektronix

Condition

Pre-Owned

Manufacturer

Tektronix

Osc_ch

4

Osc_freq

16 GHz

Osc_r

50 Ω

Osc_sampl

50 GS/s

2XL

20 M on all four channels

ASM

Advanced Event Search and Mark

DVI

Digital Visual Interface physical layer validation and compliance testing with automated eye diagram generation and parametric testing

ET3

Ethernet Compliance Testing

HT3

HDMI Compliance Testing

JA3

Advanced Jitter Analysis Software

MTH

Mask testing for Serial Standards up to 4.25 Gb/s. Includes hardware clock recovery

PTD

Protocol Trigger and Decode for 8b/10b

PTH1

3.125GB/s Serial Pattern Trigger

RTE

RT-Eye® Serial Data Compliance and Analysis Software

SST

SATA and SAS Analysis Software Module for RT-Eye Serial Data Compliance and Analysis Software

ST

Serial Trigger

TDSET3

Ethernet Compliance Test Software

TDSPTD

Protocol Trigger and Decode

TDSUSB2

USB2.0 Compliance Test Package

USB

USB2.0 Port: One in front , four on back. Allows connection or disconnection of USB keyboard , mouse or storage device while oscilloscope is on

USB2

USB 2.0 Compliance Test Software only