The Tektronix A621 and A622 are clamp-on current probes in the A600 Series, designed to support current measurements with the TekMeter or an oscilloscope. The A621 is an industrial-style clamp-on probe with a BNC connector that measures AC current. The A622 is a 'long nose' style clamp-on probe that uses a Hall Effect current sensor to provide a voltage output to oscilloscopes, and it measures both AC and DC current. Both probes terminate in a BNC connector and can be used with a shrouded banana plug adapter, so they work with digital multimeters, the TekMeter, and oscilloscopes.
A clamp-on current probe lets an engineer measure the current flowing through a conductor without breaking the circuit, sensing the conductor's magnetic field and converting it to a proportional voltage output. The A600 Series probes are designed for measurements on motor drives, inverters, power supplies, and avionics.
ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.
Tektronix, founded in 1946, was acquired by Danaher Corporation in 2007. In 2016 Danaher spun off its test and measurement portfolio into Fortive Corporation, of which Tektronix is now a part.
The A600 Series consists of two clamp-on current probes, the A621 and the A622, both designed to support current measurements with the TekMeter or an oscilloscope. The two models share a common clamp-on form factor and BNC termination but differ in coupling, current range, frequency range, and the maximum conductor diameter they accept.
The A621 is the industrial-style AC probe built for high-current measurement, while the A622 is a 'long nose' AC/DC probe that uses a Hall Effect sensor. Selecting between them comes down to whether DC content must be measured and the magnitude of the current involved.
Each new model below is listed on its own dedicated product page with condition-matched pricing. Select the model that matches your measurement requirements, then choose the configuration that fits your budget.
The clearest difference between the two models is coupling and range: the A621 measures AC current from 100 mA to 2000 A peak across 5 Hz to 50 kHz, whereas the A622 measures both AC and DC current from 50 mA to 100 A peak across DC to 100 kHz. The A622's Hall Effect current sensor is what enables its DC measurement capability.
The probes also differ physically. The A621 accepts conductors up to 54 mm (2.13 in.) in diameter and offers 1, 10, or 100 mV/A output scaling, while the A622 accepts conductors up to 11.8 mm (0.46 in.) and offers 10 or 100 mV/A scaling. Both share the same 600 V (CAT III) bare-wire voltage rating. See the comparison table below for a side-by-side summary.
| Model | Frequency Range | Max Input Current | Output |
|---|---|---|---|
| A621 | 5 Hz to 50 kHz | 2000 A peak | 1 mV/A, 10 mV/A, 100 mV/A |
| A622 | DC to 100 kHz | 100 A peak | 10 mV/A, 100 mV/A |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Specification | Value |
|---|---|
| Frequency range | 5 Hz to 50 kHz |
| Maximum input current | 2000 A peak |
| Output | 1 mV/A, 10 mV/A, 100 mV/A |
| Maximum conductor diameter | 54 mm (2.13 in.) |
| Termination | BNC |
| Maximum bare-wire voltage | 600 V (CAT III) |
| Safety | UL3111-2-032, CSA1010.2.032, EN61010-2-032, IEC61010-2-032 |
Important: For instruments with banana-jack inputs, the Tektronix 012-1450-00 Female BNC-to-banana lead adapter is required.
Recommended pairing: use these probes with Tektronix TPS2000, TDS1000B, TDS2000C, or TDS3000C Series oscilloscopes and DMM4020, DMM4040, or DMM4050 digital multimeters.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Tektronix
Condition
Factory New
Manufacturer
Tektronix
Curr_prob_freq
5 Hz to 50 kHz
Tektronix TCP404XL 500 A, 2 MHz AC/DC Current Probe (Requires TCPA400 Amplifier)
TCP404XL
Tektronix TCP303 150 A, 15 MHz AC/DC Current Probe (Requires TCPA300 Amplifier)
TCP303
Tektronix TCPA300 Current Probe Amplifier for TCP303/TCP305/TCP312
TCPA300
Tektronix TCPA400 Current Probe Amplifier for TCP404XL
TCPA400
Tektronix P6015A 1000X High-Voltage Passive Probe, 75 MHz
P6015A
Tektronix P6022 6 A, 120 MHz AC Current Probe
P6022
P5122 Tektronix Voltage Probe New
P5122
HCTEK4321 Tektronix Case New
HCTEK4321
TPS2PWR1 Tektronix Software New
TPS2PWR1
Tektronix P5100A 100X High-Voltage Passive Probe, 500 MHz
P5100A
Tektronix SIGEXPTE SignalExpress Tektronix Edition Professional Version Software
SIGEXPTE
TPSCHG Tektronix Battery Charger New
TPSCHG
TPSBAT Tektronix Battery New
TPSBAT
Tektronix P2220 1X/10X Passive Probe, 200 MHz Bandwidth
P2220
Tektronix TPP0201 10X Passive Probe, 200 MHz Bandwidth
TPP0201
Tektronix TPP0101 10X Passive Probe, 100 MHz Bandwidth
TPP0101