Key Features At A Glance

  • Multi-rate SDH/SONET testing from STM-0/OC-1 up to STM-16/OC-48 (2.5 Gb/s)
  • Optional PDH/T-carrier testing at 2, 8, 34, 140 Mb/s, DS1 and DS3
  • Jitter and wander generation and measurement from DS1 to STM-16c/OC-48c per ITU-T O.172
  • Optional ATM payload testing up to 2.5 Gb/s with ITU-T O.191 test cell support
  • Optional Packet over SONET/SDH (POS) testing at synchronous rates up to 2.5 Gb/s
  • Smartsetup autodiscover wizard identifies line rate and payload structure with simultaneous J1 trace display
  • Color VGA display with single- and multi-window modes plus front-panel VGA output
  • Concatenated payload support including STM-4c/STS-12c carried in STM-16/OC-48
Share on
View full details

The Agilent OmniBER 718 is a single-box, field-portable multi-rate SDH/SONET communications performance analyzer covering line rates from STM-0/OC-1 (52 Mb/s) up to STM-16/OC-48 (2.5 Gb/s). The instrument is positioned by its datasheet for installation, maintenance, commissioning, system verification, and manufacturing of SDH/SONET transport networks and network equipment, with optional payload modules that extend coverage to PDH/T-carrier, ATM, and Packet over SONET/SDH applications on the same platform.

The platform is offered in three model variants that map test capability to bit rate. The 37718A covers the full SDH/SONET range up to 2.5 Gb/s; the 37718B covers up to 622 Mb/s; and the 37718C covers 155 and 52 Mb/s electrical and optical. All three variants accept the same optional PDH/T-carrier module (2, 8, 34, 140 Mb/s, DS1, and DS3), the jitter option, and the ATM and POS payload options, allowing a buyer to specify the line-rate ceiling appropriate to the network under test while preserving payload and transport flexibility.

ValueTronics International, LLC stocks, inspects, and ships the Agilent OmniBER 718 from our 20,000 square foot secure warehouse at 1675 Cambridge Drive, Elgin, Illinois. Every unit that leaves our facility is performance-verified by our technicians against the manufacturer's published specifications before shipment, and condition is documented unit by unit rather than estimated from the model number. Because the OmniBER 718 is a modular platform with multiple optical, payload, and feature options, we confirm the installed option set on every unit and disclose it on the listing so the configuration you receive matches the configuration you need.

Brand Heritage

The OmniBER 718 was developed and originally manufactured by Agilent Technologies, which was spun out of Hewlett-Packard's test and measurement business in 1999. In 2014 Agilent's electronic measurement division was separated as Keysight Technologies, which is the current corporate successor for this product line's service, calibration, and documentation support.

Compare Other Models in This Series

The OmniBER 718 family is documented in the datasheet as three model variants distinguished by their maximum SDH/SONET line rate. All three share the same chassis, the same Smartsetup and Smart Tests operating model, the same payload option set, and the same jitter, ATM, and POS option modules. The variants differ only in the ceiling of the supported optical and electrical line rates, allowing a buyer to specify the rate envelope appropriate to the network under test without changing the rest of the test workflow.

Because the platform options are common across the variants, the choice between 37718A, 37718B, and 37718C is primarily a question of whether 2.5 Gb/s and 622 Mb/s coverage are needed. The same PDH/T-carrier module (option 012), the same jitter option (option 200), the same ATM option (option 300), and the same POS option (option 310) are available on all three variants.

Each pre-owned OmniBER 718 model in the family below is its own dedicated product page with condition-matched pricing, option configuration, and accessory listing. Select the model that matches the line-rate ceiling your network requires.

The 37718A is the full-rate variant covering 2.5 Gb/s, 622 Mb/s, 155 Mb/s, and 52 Mb/s SDH/SONET line rates. Its optical receiver wavelength range covers 1280 to 1335 nm and 1500 to 1580 nm with STM-16/OC-48 sensitivity of -28 dBm and maximum input power of -8 dBm. The 37718A uses a customer-exchangeable optical connector system.

The 37718B covers 622 Mb/s, 155 Mb/s, and 52 Mb/s SDH/SONET line rates (no 2.5 Gb/s). The 37718C covers 155 Mb/s and 52 Mb/s only. Both the 37718B and 37718C share an optical receiver wavelength range of 1200 to 1600 nm, sensitivity of -28 dBm at their respective top rates, and maximum input power of -3 dBm. Both use a fixed optical connector system that supports removal for cleaning.

Model SDH/SONET Rates Optional PDH/T-carrier Max Optical Rate
37718B 622, 155, 52 Mb/s 2, 8, 34, 140 Mb/s, DS1 (1.5 Mb/s), DS3 (45 Mb/s) 622 Mb/s (STM-4/OC-12)
37718A 2.5 Gb/s, 622, 155, 52 Mb/s 2, 8, 34, 140 Mb/s, DS1 (1.5 Mb/s), DS3 (45 Mb/s) 2.5 Gb/s (STM-16/OC-48)
37718C 155, 52 Mb/s 2, 8, 34, 140 Mb/s, DS1 (1.5 Mb/s), DS3 (45 Mb/s) 155 Mb/s (STM-1/OC-3)

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Product Core & Specifications

Specification Value
General
Supply 90 to 260 Vac nominal; 47 to 63 Hz, 450 VA nominal
Dimensions (H x W x D) 7.5 x 13.40 x 18.5 in (x 20.10 in with lid fitted); 190 x 340 x 470 mm (x 510 mm with lid fitted)
Weight 16 kg (typical); 35 lb
Internal clock basic accuracy < 0.5 ppm at 77 °F (25 °C)
Temperature stability < 3 ppm over operating temperature range
Ageing rate < 1 ppm per year
Operating temperature 32 to 113°F (0 to 45 °C)
Storage temperature 68 to 168 °F (−20 to + 70 °C)
Humidity range 15% to 95% RH
Installation category Installation category II, pollution degree two per IEC 61010-1 and 60664
Regulatory Standards
Product safety EN 61010-1 (1993); IEC 1010-1 (1990) +A1 (1992) +A2 (1995); CSA C-22.2 No 1010.1-92
EMC immunity EN 50082-1 (1992)
EMC emissions EN 55011 (1991), Group 1 Class A
Laser safety 21 CFR CH.1 1040; EN 60825-1 (1994); Class 1 laser product
SDH Capability
SDH rates STM-16, STM-4, STM-1, STM-0 (model-dependent)
Electrical line rates/interfaces STM-1e (CMI) to ITU-T G.703, STM-0e (B3ZS)
Connector BNC, 75 ohm nominal unbalanced
Clock reference internal ± 0.5 ppm; stability: ± 3 ppm; ageing: ± 1 ppm
External reference 2M (MTS), 1.5 M (BITS), 64 kb/s, 10 MHz
Clock offset ± 999 ppm in 0.1 ppm steps
Payload offset ± 100 ppm in 1 ppm steps, linearity 0.5 ppm
Payload test patterns 2^9-1, 2^11-1, 2^15-1, 2^23-1 (inverted or non-inverted), all ones, all zeros, 1010, 1000, 16 bit user word
SDH alarms (generation) LOS, LOF, OOF, MS-AIS, MS-RDI, AU-AIS, AU-LOP, HP-RDI, HP-unequipped, TU-AIS, LP-RDI, TU-LOP, LP-unequipped, H4 LOM
SDH errors (generation) Data (whole frame), frame (A1,A2), B1, B2, MS-REI, HP B3, HP-REI, AU4-IEC, LP BIP-2, LP-REI, bit
Performance analysis ITU-T G.821, G.826, M.2101, M.2110, M.2120
SONET Capability (Option 002)
SONET rates OC-48, OC-12, OC-3, OC-1, STS-3, STS-1 (model-dependent)
Electrical line rates/interfaces STS-3 (CMI), STS-1 (B3ZS)
Connector BNC, 75 ohm unbalanced (Option 620: WECO 560 replaces BNC)
External reference BITS (1.5 Mb/s), 64 kb/s, 10 MHz
Clock offset ± 999 ppm in 0.1 ppm steps; offset accuracy ± 0.02 ppm
SONET alarms (generation) LOS, LOF, OOF, AIS-L, RDI-L, AIS-P, RDI-P, LOP-P, UNEQ-P, AIS-V, LOP-V, RDI-V, UNEQ-V, H4 LOM
SONET errors (generation) Data (whole frame), frame (A1,A2), CV-S (B1), CV-L (B2), REI-L (M0), REI-L (M1), CV-P (B3), REI-P (G1), STS IEC, CV-V (V5), REI-V (V5), bit
Performance analysis G.826, G.821, M.2101, M.2110, M.2120
PDH/T-Carrier (Option 012)
Line rates 2/8/34/140 Mb/s, DS1 (1.5 Mb/s), DS3 (45 Mb/s)
2 Mb/s HDB3/AMI; 75 ohm unbalanced (BNC), 120 ohm balanced
8 Mb/s HDB3; 75 ohm unbalanced (BNC)
34 Mb/s HDB3; 75 ohm unbalanced (BNC)
140 Mb/s CMI; 75 ohm unbalanced (BNC)
DS1 B8ZS/AMI; 100 ohm balanced
DS3 B3ZS; 75 ohm unbalanced (BNC)
Line rate offset ± 100 ppm in 1 ppm steps
Performance analysis ITU-T G.821 (bit), G.826, M.2100, M.2110, M.2120
Jitter (Option 200)
Jitter generation rates SDH/SONET 2.5 Gb/s, 622 Mb/s, 155 Mb/s, 52 Mb/s
Jitter generation rates PDH/T-carrier 140 Mb/s, 34 Mb/s, 8 Mb/s, 2 Mb/s, DS1 (1.5 Mb/s), DS3 (45 Mb/s)
Wander generation rates SDH/SONET 2.5 Gb/s, 622 Mb/s, 155 Mb/s, 52 Mb/s
Wander generation rates PDH/T-carrier 2 Mb/s, DS1 (1.5 Mb/s)
Jitter generation compliance Meets ITU-T O.171 (PDH), ITU-T O.172 (SDH); exceeds ITU-T G.823, G.825, G.958, Bellcore GR-253
Optical sensitivity (jitter) -12 to -20 dBm for 2.5 Gb/s; -10 to -22 dBm for 52, 155, 622 Mb/s
External jitter modulation input 10 UI: 2/8/34/140 Mb/s; 20 UI: SDH/SONET rates, DS1, DS3
ATM (Option 300)
ATM payloads Up to 2.5 Gb/s
ATM framing STS-1, STS-3c, STS-12c, STS-48c (Bellcore GR-253); VC-4, VC-4-4c, VC-4-16c (ITU-T G.707); 34 Mb/s (ITU-T G.832); 2 Mb/s (PCM30, PCM30CRC); DS3 (C-bit parity); DS1 (ESF)
Cell scrambling On/off, conforms to ITU-T I.432
POS (Option 310)
POS payload rates OC-48/STM-16 (2.5 Gb/s), OC-12/STM-4 (622 Mb/s), OC-3/STM-1o/e (155 Mb/s), OC-1/STS-1/STM-0o/e (52 Mb/s)
Framing formats PPP in HDLC (RFC 1662); Cisco HDLC
Frame check sequence CRC-16 (not available at 2.5 Gb/s); CRC-32 (all rates)
Important: The OmniBER 718 is classified as a Class 1 laser product per EN 60825-1 (1994) and FDA 21 CFR Ch.1 1040.10 (1994).Important: STM-16/OC-48 (2.5 Gb/s) mappings are only available on the 37718A fitted with an optical interface option (Option 104, 105, or 106).Important: STM-4/OC-12 (622 Mb/s) mappings are only available on the 37718A or 37718B fitted with an optical interface option (Option 104, 105, or 106).Important: Option 012 (PDH/T-carrier testing) is required for 2/34/140 Mb/s/DS1/DS3 mappings on SDH/SONET payloads.Important: Option 002 (SONET) is required for DS1 add/drop from DS3 and for DS1 drop/insert from SDH/SONET line signals.Important: Option 014 is required for testing 2 Mb/s mapped into DS3.Important: Option 350 is required for service disruption timestamping (first 10 events) and AIS duration measurements on STS-48c, STS-12c, STS-3c, STS-1, AU-4-16c, AU-4-4c, AU-4, and AU-3 tributaries.Important: Service disruption measurement: it is recommended that unframed signals are used to measure service disruption as frame sync times will affect the measurement.Important: Instruments with Option 210 fitted must be returned to factory for calibration. OmniBER calibration is recommended once every two years.Important: Optical interfaces on the 37718A use a customer exchangeable connector system. On 37718B and 37718C models, a fixed connector system is used (supports removal for cleaning).Important: The OmniBER 718 is a Class 1 laser product per EN60825-1 (1994) and FDA 21 CFR CH.1 1040.10 (1994).Important: For remote control via PC (E4540A DNA software), an RS-232-C or LAN remote control interface (Option 601) must also be ordered.Important: Optical interface options (Option 104, 105, or 106) must be ordered separately to enable optical SDH/SONET testing; the base instrument supports electrical interfaces only without these options.Recommended pairing: when ordering an OmniBER 718 with optical interface options, the Agilent E4545A 3 m fiber optic cable (FC/PC) and the E4546A 15 dB FC/PC optical attenuator are listed in the datasheet's accessories section as the matched fiber accessories for this instrument.

About this used unit

  • Warranty included.
  • Functional verification included.
  • Standard Calibration Upgrade Options: No Calibration Required, NIST Traceable, Z540.1 or ISO 17025 with Data, Z540.3 Guardbanding with Data.