Skip to product information
1 of 1
Used
lab tested

GUARDIAN 6000 PLUS QuadTech HiPot Used

GUARDIAN 6000 PLUS QuadTech HiPot Used

Shipping calculated at checkout.
Calibrations
check availability
Login & Get 2% Back on Purchases
Login or Sign Up for Loyalty

Features:

  • Five instruments in one: AC Hipot (hypot), DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
  • Twin-Port™ feature (Patented)
  • Programmable output voltage to 5kV AC and 6kV DC
  • Insulation resistance to 50GO/1000V DC
  • Ground bond up to 30A (Option up to 40A / 60A)
  • Open/Short check (OSC) function
  • ARC detection (Flashover)
  • Password Protected front panel lockout
  • Storage of 50 Tests Setups with 100 Steps per setup
  • Optional dynamic leakage current auto scanning
  • Standard RS-232 Interface
  • Standard GB OFF.S.ET KIT, SCANNER Interface
  • Optional GPIB Interface
Share on
View full details

Applications:

  • ITE / consumer electronic safety testing
  • Transformer safety testing
  • Generator/motor safety testing
  • Component safety testing
  • Non-electronic safety testing
  • Appliance electrical safety testing
  • Medical equipment safety testing

Specifications:

  • Output Voltage: DC:0.05 ~ 6kV , AC : 0.05 ~ 5kV
  • Load Regulation: ±(1% of reading +0.1% of range)
  • Voltage Regulation: 2V
  • Voltage Accuracy: ±(1% of reading +0.1% of range)
  • Cutoff Current: DC : 20mA , AC : 40mA
  • Current Resolution: 0.1 μA DC
  • Current Accuracy: ±(1% of reading +0.1% of range)
  • Output Frequency: 50Hz / 60Hz
  • Test Time: 0.3 ~ 999 sec , continue
  • Ramp Time: 0.1 ~ 99.9 sec, Off
  • Fall Time: 0.1 ~ 99.9 sec, Off
  • Waveform: Sine wave

The Guardian 6000 Plus is able to perform several dielectric tests in one unit including AC/DC Hipot, Insulation Resistance,Ground Bond, Open/Short Check and optional Leakage Current for compliance testing of IEC, UL, TUV, CSA, EN and other standards including IEC60601-1, UL2601-1, IEC950, UL544, UL60950. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half.  The open / short check function (OSC) checks for an open connection or a DUT short during testing.  Open connections may cause a bad DUT to test OK.  Screening for shorts prevents damage to the equipment saving potential costs that may occur. These patented features are only available in safety products manufactured by Chroma.

Model No

GUARDIAN

Condition

Used

Manufacturer

QuadTech