| Item/Model | PAV10-40 | PAV20-20 | PAV36-12 | PAV60-7 | PAV100-4 | PAV160-2.6 | PAV320-1.3 | PAV650-0.64 |
|---|---|---|---|---|---|---|---|---|
| Rated output voltage *1 | 10V | 20V | 36V | 60V | 100V | 160V | 320V | 650V |
| Rated output current *2 | 40A | 20A | 12A | 7A | 4A | 2.6A | 1.3A | 0.64A |
| Rated output power | 400W | 400W | 432W | 420W | 400W | 416W | 416W | 416W |
| Item/Model | PAV10-40 | PAV20-20 | PAV36-12 | PAV60-7 | PAV100-4 | PAV160-2.6 | PAV320-1.3 | PAV650-0.64 | |
|---|---|---|---|---|---|---|---|---|---|
| Maximum line regulation *5 (for the rated output voltage) | 0.01% +2mV | 0.01% | |||||||
| Maximum load regulation *6 (for the rated output voltage) | |||||||||
| Ripple noise *7 | 20 MHz, p-p | 50mV | 50mV | 50mV | 50mV | 80mV | 100mV | 150mV | 250mV |
| 5 Hz to 1 MHz, rms | 5mV | 6mV | 6mV | 7mV | 8mV | 10mV | 25mV | 60mV | |
| Temperature coefficient | 30 PPM /°C (after a 30 minute warm-up, for the rated output voltage) | ||||||||
| Aging drift *8 (for the rated output voltage) | 0.02% | ||||||||
| Initial drift *9 (for the rated output voltage) | 0.05% +2 mV | 0.05% | |||||||
| Maximum remote sensing compensation voltage (single line (positive or negative)) | 1V | 1V | 2V | 3V | 5V | 5V | |||
| Rise time *10 | 15ms | 30ms | 30ms | 50ms | 50ms | 80ms | 150ms | 150ms | |
| Fall time | At full load *10 | 10ms | 10ms | 15ms | 30ms | 50ms | 100ms | 150ms | 150ms |
| Td (typ) *11 | 210ms | 250ms | 320ms | 380ms | 1200ms | — | |||
| No load a *12 | 40ms | 65ms | 85ms | 100ms | 250ms | — | |||
| No load b *13 | 200ms | 200ms | 290ms | 310ms | 1100ms | 2000ms | 2500ms | 3000ms | |
| Transient response time *14 | 1 ms or less | 2 ms or less | |||||||
| Output hold time (typ) *15 | 15ms | 16ms | 16ms | 15ms | |||||
| Item/Model | PAV10-40 | PAV20-20 | PAV36-12 | PAV60-7 | PAV100-4 | PAV160-2.6 | PAV320-1.3 | PAV650-0.64 |
|---|---|---|---|---|---|---|---|---|
| Maximum line regulation *5 (at the rated output current) | 0.01% +2mA | 0.02% | ||||||
| Maximum load regulation *16 (at the rated output current) | 0.01% +5mA | 0.09% | ||||||
| Change in the load due to the temperature drift of internal components (at the rated output current) | 0.05% or less (for 30 minutes after the load conditions are changed) | |||||||
| Ripple noise *17 (5 Hz to 1 MHz, rms) | 70mA | 40mA | 15mA | 8mA | 3mA | 1.5mA | 1mA | 0.6mA |
| Temperature coefficient | 100PPM/℃(30分ウォームアップ後、定格出力電流に対して) | |||||||
| Aging drift *8 (at the rated output current) | 0.05% | |||||||
| Initial drift *9 (at the rated output current) | 0.1% | |||||||
| Item/Model | PAV10-40 | PAV20-20 | PAV36-12 | PAV60-7 | PAV100-4 | PAV160-2.6 | PAV320-1.3 | PAV650-0.64 |
|---|---|---|---|---|---|---|---|---|
| Nominal input rating | 100 Vac to 240 Vac continuous input, 50 Hz to 60 Hz, single phase | |||||||
| Input voltage range | 85 Vac to 265 Vac | |||||||
| Input frequency range | 47 Hz to 63 Hz | |||||||
| Input current (typ) *3 (100 Vac/200 Vac) | 5.05A/2.47A | 4.98A/2.45A | 5.25A/2.57A | 5.10A/2.50A | 4.80A/2.37A | 5A/2.44A | ||
| Power factor (typ) (100 Vac/200 Vac, at the rated output power) | 0.99 | |||||||
| Efficiency (typ) *3 | 80%/82% | 81%/83% | 83%/85% | 83%/85% | 84%/88% | 84%/86% | ||
| Inrush current (100 Vac/200 Vac) *4 | 25 A / 25 A or less | 25 A / 25 A or less | ||||||
Model No
PAV650-0.64
Condition
New
Manufacturer
Kikusui
Current
0.64 A
Voltage
650 V
Power
400 W