The Keysight N8900 Series is a family of autoranging, single-output programmable DC power supplies engineered for ATE applications that require flexible voltage and current combinations from a single instrument. The series consists of 28 models spanning 5 kW, 10 kW, and 15 kW output power, with output coverage from 80 V to 1500 V and 20 A to 510 A. Fourteen models accept 208 VAC three-phase input and fourteen accept 400 VAC three-phase input, allowing deployment in any major regional power environment.
The defining characteristic of the N8900 Series is its autoranging output. Conventional rectangular-output DC supplies deliver full rated power at only one voltage/current combination; outside that point, available power drops. An autoranging supply expands the usable power envelope, so a single N8900 model covers a wide range of voltage and current operating points at full rated power. For example, a 1000 V, 30 A, 10 kW model can deliver 1000 V at 10 A or 333.3 V at 30 A — both at the full 10 kW rating.
ValueTronics International has supplied professional test and measurement equipment to engineers, calibration labs, and ATE integrators since 1992. All inventory — including programmable DC power supplies in the N8900 family — is stocked and tested in our 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Equipment is inspected and verified in-house before shipment, and configuration questions on autoranging supplies, parallel master/slave setups, and interface options are answered by staff who handle these units directly rather than routed to a drop-ship partner.
Keysight Technologies was established in 2014 as the test and measurement spin-off from Agilent Technologies, which itself was formed in 1999 when Hewlett-Packard separated its instrumentation business from its computing business. The N8900 Series power supplies are part of the Keysight DC power product line that traces its engineering heritage through this Agilent and Hewlett-Packard lineage.
The N8900 Series is organized into 28 models defined by three primary axes: maximum output power (5 kW, 10 kW, or 15 kW), AC input voltage (208 VAC or 400 VAC three-phase), and output voltage/current rating. Every model in the family shares the same autoranging output characteristic, the same standard interface set (LAN, USB, GPIB, analog), the same 3U form factor, and the same protection feature set. The differences between models are confined to the output ratings and the AC input voltage selection.
The 208 VAC models (N8920A through N8937A) are designated for nominal 187–229 VAC input regions. The 400 VAC models (N8940A through N8957A) are designated for nominal 360–440 VAC input regions. Within each input-voltage group, the 5 kW, 10 kW, and 15 kW power tiers each offer multiple voltage/current combinations — for example, the 5 kW tier covers 80 V/170 A, 200 V/70 A, 500 V/30 A, and 750 V/20 A. Selecting the correct model is a matter of matching the required output envelope and the available AC input.
Each new N8900 model linked from this page has its own dedicated product listing with condition-matched pricing, current availability, and the specific model's output ratings and AC input requirement. Use the comparison table to identify the model that matches your application, then open the individual model page for pricing and ordering detail.
Across the family, output voltage ratings span 80 V, 200 V, 500 V, 750 V, 1000 V, and 1500 V. Output current ratings scale inversely with voltage at each power tier. At 5 kW, current ratings range from 20 A on the 750 V model to 170 A on the 80 V model. At 10 kW, current ratings range from 30 A on the 1000 V model to 340 A on the 80 V model.
AC input current draw and inrush current scale with the power tier. The 5 kW models draw 2 × 32 A on 208 VAC or 2 × 16 A on 400 VAC with 41 A (208 VAC) or 28 A (400 VAC) inrush. The 10 kW models draw 2 × 32 A + 1 × 56 A on 208 VAC or 2 × 16 A + 1 × 28 A on 400 VAC with 97 A (208 VAC) or 49 A (400 VAC) inrush. The 15 kW models draw 3 × 56 A on 208 VAC or 3 × 28 A on 400 VAC.
| Model | Max Voltage | Max Current | Max Power |
|---|---|---|---|
| N8929A | 750 V | 40 A | 10 kW |
| N8920A | 80 V | 170 A | 5 kW |
| N8921A | 200 V | 70 A | 5 kW |
| N8923A | 500 V | 30 A | 5 kW |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
| Supplemental Characteristics (All Models) | |
|---|---|
| Analog Programming | |
| Input range | Selectable: 0 to 5 V or 0 to 10 V |
| Accuracy | Specified accuracy + 0.2% of rating |
| Input impedance | 150 kΩ |
| Referenced to | Ground |
| Temperature Coefficients (after 30 minute warmup) | |
| Voltage | 50 PPM/°C of rated output voltage |
| Current | 50 PPM/°C of rated output current |
| Operation | |
| Series operation | Not recommended |
| Parallel operation (Master-slave) | Yes |
| Savable states (Nonvolatile memory) | 10 |
| Interface Capabilities | |
| GPIB, USB 2.0, 10/100 LAN | SCPI - 1993, IEEE 488.2 compliant interface; Requires Keysight I/O Libraries 16.3 or later |
| LXI compliance | LXI Core 2011 compliant |
| Environmental Conditions | |
| Environment | Indoor use, installation category II (AC input), pollution degree 2 |
| Operating temperature | 0 °C to 45 °C |
| Storage temperature | −20 °C to 70 °C |
| Operating humidity | 80% |
| Storage humidity | 80% |
| Altitude | 2000 m |
| Built-in Web server | Requires Internet Explorer 7+, Firefox, or Chrome. Additionally requires Java plug-in and the Java Runtime Environment. |
| AC Input - 208 VAC Models (N8920A - N8937A) | |
| Nominal input voltage | 208 VAC |
| Input range | Nominal ±10% |
| Frequency | 45-65 Hz |
| Phase | 3 phase |
| Power factor | > 0.99 |
| AC Input - 400 VAC Models (N8940A - N8957A) | |
| Nominal input voltage | 400 VAC |
| Input range | Nominal ±10% |
| Frequency | 45-65 Hz |
| Phase | 3 phase |
| Power factor | > 0.99 |
| Load Transient Recovery Time | |
| Time | ≤ 1.5 ms (for output voltage to recover within 1% of its rated output for a load change from 10% to 90% of its rated output current) |
| Output Response Time | |
| Up, full load | ≤ 30 ms |
| Down, full load | ≤ 80 ms |
| Command Response Time | |
| Command response time | < 25 ms |
| Regulatory Compliance | |
| EMC | Complies with European EMC Directive for test and measurement products; Complies with Australian standard and carries C-Tick mark; Complies with Canadian ICES-001 |
| Safety | Complies with European Low Voltage Directive and carries the CE-marking; Complies with US and Canadian safety regulations; Not applicable for IT mains supply systems |
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Model No
Keysight
Condition
New
Manufacturer
Keysight
Current
40 A
Voltage
750 V
Power
10 kW